Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Circuit Breakers

Use the filters and product table below to compare Circuit Breakers components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Breaker Type Current Rating (Amps) Voltage Rating - AC Voltage Rating - DC Actuator Type Number of Poles Illumination Illumination Voltage (Nominal) Approval Agency
BDL26025LU Schneider Electric

BDL26025LU

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

3,011 -
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 25A 525 V - Toggle 2 None - EN 60947-2, IEC 60947-2
BDL46030 Schneider Electric

BDL46030

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

9,983 -
Datasheet PowerPact Box Active DIN Rail Thermal Magnetic 30A 525 V - Toggle 4 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDF46030 Schneider Electric

BDF46030

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

2,784 -
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 30A 525 V - Toggle 4 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BGA24125Y1 Schneider Electric

BGA24125Y1

MOLDED CASE CIRCUIT BRKR 480Y/27

Schneider Electric

3,495 -
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 125A 525 V - Toggle 2 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDA260804 Schneider Electric

BDA260804

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

5,569 -
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 80A 525 V - Toggle 2 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDF36025 Schneider Electric

BDF36025

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

7,360 -
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 25A 525 V - Toggle 3 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDA261252 Schneider Electric

BDA261252

MOLDED CASE CIRCUIT BREAKER 600Y

Schneider Electric

2,093 -
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 125A 525 V - Toggle 2 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDA261251 Schneider Electric

BDA261251

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

2,387 -
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 125A 525 V - Toggle 2 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
BDA260901 Schneider Electric

BDA260901

MOLDED CASE CIRCUIT BRKR 600Y/34

Schneider Electric

3,657 -
Datasheet PowerPact Box Obsolete DIN Rail Thermal Magnetic 90A 240 V 48 V Toggle 2 None - CSA C22.2 No 5, EN 60947-2, EN 60947-5-1, GB 14048.2, IEC 60947-2, IEC 60947-5-1, UL489
EDB36050AABA Schneider Electric

EDB36050AABA

MINIATURE CIRCUIT BREAKER 600V 5

Schneider Electric

9,125 -
Datasheet - Box Obsolete - - - - - - - - - -
Total 5206 Record«Prev1... 266267268269270271272273...521Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Circuit Breakers?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Circuit Breakers FAQ

Common questions about filtering, comparing and sourcing Circuit Breakers components.

How can I narrow the Circuit Breakers selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Circuit Breakers part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.