Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
EXPLORE COMPONENTS

Contactors (Electromechanical)

Browse available Contactors (Electromechanical) part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.

For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.

Compare Part Numbers Review available models and manufacturers
Datasheets & Specifications Access technical references quickly
RFQ & BOM Support Send quantities for sourcing and quotation
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Features Termination Style Operating Temperature Must Operate Voltage Must Release Voltage
LC1K0901E7 Schneider Electric

LC1K0901E7

3P CONTACTOR 9A AC3 4KW 1NC 48VA

Schneider Electric

2,963 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal - 38.4 VAC 9.6 VAC
LC1K0901B7 Schneider Electric

LC1K0901B7

3P CONTACTOR 9A AC3 4KW 1NC 24VA

Schneider Electric

4,539 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal - 19.2 VAC 4.8 VAC
LP1K0610JD Schneider Electric

LP1K0610JD

3P CONTACTOR 6A AC3 2.2 KW 12VDC

Schneider Electric

4,805 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 12VDC 3PST-NO (3 Form A) 6 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 50°C 9.6 VDC 1.2 VDC
LP1K0610FD Schneider Electric

LP1K0610FD

3P CONTACTOR 6A AC3 2.2KW 110VDC

Schneider Electric

1,409 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 110VDC 3PST-NO (3 Form A) 6 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 50°C 88 VDC 11 VDC
LC1K0901P7 Schneider Electric

LC1K0901P7

CONTACTOR

Schneider Electric

3,631 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 230VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal - 184 VAC 46 VAC
LC1K09004E7 Schneider Electric

LC1K09004E7

4P CONTACTOR 20A AC1 48VAC COIL

Schneider Electric

4,927 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VAC 4PST-NO (4 Form A) 20 A 690VAC - Max - Screw Terminal - 38.4 VAC 9.6 VAC
LP1K0610ED Schneider Electric

LP1K0610ED

3P CONTACTOR 6A AC3 2.2KW 48VDC

Schneider Electric

4,745 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VDC 3PST-NO (3 Form A) 6 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 50°C 38.4 VDC 4.8 VDC
LC1K09004B7 Schneider Electric

LC1K09004B7

4P CONTACTOR 20A AC1 24VAC COIL

Schneider Electric

3,945 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VAC 4PST-NO (4 Form A) 20 A 690VAC - Max - Screw Terminal - 19.2 VAC 4.8 VAC
LC1K09004F7 Schneider Electric

LC1K09004F7

CONTACTOR-4NO 20A AC1 POLES

Schneider Electric

4,490 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 110VAC 4PST-NO (4 Form A) 20 A 690VAC - Max - Screw Terminal - 88 VAC 22 VAC
LC1K0901U7 Schneider Electric

LC1K0901U7

3P CONTACTOR 9A AC3 4KW 1NC 240V

Schneider Electric

1,616 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 230 ~ 240VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal - - -
LP1K06105BD Schneider Electric

LP1K06105BD

CONTACTOR

Schneider Electric

1,610 -
Datasheet TeSys Box Active Through Hole 24VDC 3PST-NO (3 Form A) 6 A 690VAC - Max Auxiliary Contacts PC Pins -25°C ~ 50°C 19.2 VDC 2.4 VDC
LC1K0901G7 Schneider Electric

LC1K0901G7

CONTACTOR

Schneider Electric

2,204 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 120VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal - 96 VAC 24 VAC
LC1K0901Q7 Schneider Electric

LC1K0901Q7

CONTACTOR

Schneider Electric

1,189 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 380 ~ 400VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal - - -
LC1K0901M7 Schneider Electric

LC1K0901M7

3P CONTACTOR 9A AC3 4KW 1NC 220V

Schneider Electric

2,335 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 220 ~ 230VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal - - -
LC1K09017B7 Schneider Electric

LC1K09017B7

CONTACTOR

Schneider Electric

3,107 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Quick Connect - 0.110"/0.250" - 19.2 VAC 4.8 VAC
LP1K0610BD Schneider Electric

LP1K0610BD

3P CONTACTOR 6A AC3 2.2KW 24VDC

Schneider Electric

3,532 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VDC 3PST-NO (3 Form A) 6 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 50°C 19.2 VDC 2.4 VDC
LC1K0901D7 Schneider Electric

LC1K0901D7

CONTACTOR

Schneider Electric

3,339 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 42VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal - 33.6 VAC 8.4 VAC
LP1K0610MD Schneider Electric

LP1K0610MD

CONTACTOR

Schneider Electric

1,101 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 220VDC 3PST-NO (3 Form A) 6 A 690VAC - Max Auxiliary Contacts Screw Terminal -25°C ~ 50°C 176 VDC 22 VDC
MC-32A-AC230V Altech Corporation

MC-32A-AC230V

CONTACTOR 3P 32A 2 NO/2 NC 230VA

Altech Corporation

2,487 -
Datasheet * Bulk Active - - - - - - - - - -
MC-32A-AC24V Altech Corporation

MC-32A-AC24V

CONTACTOR 3P 32A 2 NO/2 NC 24VAC

Altech Corporation

4,131 -
Datasheet * Bulk Active - - - - - - - - - -
Total 14795 Record«Prev1... 130131132133134135136137...740Next»
WINSUN SOURCING SUPPORT

Need Contactors (Electromechanical) Sourcing Support?

Send the manufacturer, part number, quantity and target delivery requirement. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and hard-to-find or obsolete components.

Global component sourcing support BOM, shortage and EOL support
FREQUENTLY ASKED QUESTIONS

Contactors (Electromechanical) FAQ

Common questions about selecting, comparing and sourcing Contactors (Electromechanical) components through Winsun (HK) Electronics.

What should I check when selecting Contactors (Electromechanical) components?

Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.

Can Winsun help source specific Contactors (Electromechanical) part numbers?

Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.

Do you support shortage, obsolete or hard-to-find Contactors (Electromechanical) parts?

Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.

How do I request a quote for Contactors (Electromechanical) components?

Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.