Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Contactors (Electromechanical)

Use the filters and product table below to compare Contactors (Electromechanical) components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Features Termination Style Operating Temperature Must Operate Voltage Must Release Voltage
LC1D65ABD Schneider Electric

LC1D65ABD

TESYS 3P EVLK CTR 65A 30KW AC3 2

Schneider Electric

4,914 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VDC 3PST-NO (3 Form A) 65 A 690VAC, 300VDC - Max Auxiliary Contacts, Diode Screw Terminal -40°C ~ 70°C 18 VDC 2.4 VDC
LC2D18F7 Schneider Electric

LC2D18F7

TESYS3P REVERS CTR18A AC3 9KW110

Schneider Electric

2,547 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 110VAC 3PST-NO (3 Form A) 18 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 88 VAC 33 VAC
LC2D18B7 Schneider Electric

LC2D18B7

TESYS 3P REVERS CTR18A AC3 9KW24

Schneider Electric

1,422 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VAC 3PST-NO (3 Form A) 18 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 19.2 VAC 7.2 VAC
LC1D80ED Schneider Electric

LC1D80ED

CONTACTOR

Schneider Electric

1,402 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VDC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 40.8 VDC 4.8 VDC
LC1D80BD Schneider Electric

LC1D80BD

CONTACTOR 80A 1F+1O 24V CC

Schneider Electric

1,380 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VDC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 20.4 VDC 2.4 VDC
LC2D25G7 Schneider Electric

LC2D25G7

TESYS REVERSING CONTACTOR

Schneider Electric

2,470 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 120VAC 3PST-NO (3 Form A) 25 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 96 VAC 36 VAC
LC1D80E7 Schneider Electric

LC1D80E7

3P CONT 80A AC3 37KW 1NO 1NC 48V

Schneider Electric

1,695 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VAC 3PST-NO (3 Form A) 80 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 40.8 VAC 14.4 VAC
LC1D115G7 Schneider Electric

LC1D115G7

CONTACTOR

Schneider Electric

3,337 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 120VAC 3PST-NO (3 Form A) 115 A 1000VAC, 300VDC - Max Auxiliary Contacts, Diode Screw Terminal -40°C ~ 70°C 96 VAC 36 VAC
LC1D115F7 Schneider Electric

LC1D115F7

CONTACTOR TESYSDECA 115A 3P 110V

Schneider Electric

3,083 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 110VAC 3PST-NO (3 Form A) 115 A 1000VAC, 300VDC - Max Auxiliary Contacts, Diode Screw Terminal -40°C ~ 70°C 88 VAC 33 VAC
LC1D65F7 Schneider Electric

LC1D65F7

3P CONT 65A AC3 30KW 1NO 1NC 110

Schneider Electric

3,007 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 110VDC 3PST-NO (3 Form A) 65 A 690VAC - Max Auxiliary Contacts, Diode Screw Terminal - 88 VDC 11 VDC
Total 1819 Record«Prev1... 1112131415161718...182Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Contactors (Electromechanical)?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Contactors (Electromechanical) FAQ

Common questions about filtering, comparing and sourcing Contactors (Electromechanical) components.

How can I narrow the Contactors (Electromechanical) selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Contactors (Electromechanical) part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.