Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Contactors (Electromechanical)

Use the filters and product table below to compare Contactors (Electromechanical) components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Features Termination Style Operating Temperature Must Operate Voltage Must Release Voltage
CA2KN223P72 Schneider Electric

CA2KN223P72

RELAY SPRING TERMINALS

Schneider Electric

2,011 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 230VAC 4PST-2NO/2NC (2 Form A, 2 Form B) 10 A 690VAC - Max Diode Spring Terminal -25°C ~ 50°C 184 VDC 46 VAC
CA2KN22F72 Schneider Electric

CA2KN22F72

ELECTROMAGNETIC RELAY

Schneider Electric

3,440 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 110VAC 4PST-2NO/2NC (2 Form A, 2 Form B) 10 A 690VAC - Max Diode Screw Terminal -25°C ~ 50°C 88 VAC 22 VAC
CA2KN22G72 Schneider Electric

CA2KN22G72

AUXILIARY CONT K 2F 2O 120VAC SU

Schneider Electric

2,167 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 120VAC 4PST-2NO/2NC (2 Form A, 2 Form B) 10 A 690VAC - Max Diode Screw Terminal -25°C ~ 50°C 96 VAC 24 VAC
CA2KN31P72 Schneider Electric

CA2KN31P72

ELECTROMAGNETIC RELAY

Schneider Electric

3,513 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 230VAC 4PST-3NO/1NC (3 Form A, 1 Form B) 10 A 690VAC - Max Diode Screw Terminal -25°C ~ 50°C 184 VAC 46 VAC
CA2KN40B72 Schneider Electric

CA2KN40B72

ELECTROMAGNETIC RELAY

Schneider Electric

2,068 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VAC 4PST-NO (4 Form A) 10 A 690VAC - Max Diode Screw Terminal -25°C ~ 50°C 19.2 VDC 4.8 VAC
LC1D12BNE Schneider Electric

LC1D12BNE

TESYS CONTACTOR-3P-AC3- <= 440V

Schneider Electric

1,539 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24 ~ 60VAC/DC 3PST-NO (3 Form A) 12 A 690VAC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C - -
LC1K0610Q7 Schneider Electric

LC1K0610Q7

CONTACTOR

Schneider Electric

3,066 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 380 ~ 400VAC 3PST-NO (3 Form A) 6 A 690VAC - Max Auxiliary Contacts Screw Terminal - - -
LC1K0601E7 Schneider Electric

LC1K0601E7

3P CONTACTOR 6A AC3 2.2KW 1NC 48

Schneider Electric

3,523 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VAC 3PST-NO (3 Form A) 6 A 690VAC - Max Auxiliary Contacts Screw Terminal - 38.4 VAC 9.6 VAC
CA3KN22JD Schneider Electric

CA3KN22JD

ELECTROMAGNETIC RELAY

Schneider Electric

3,418 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 12VDC 4PST-2NO/2NC (2 Form A, 2 Form B) 10 A 690VAC - Max - Screw Terminal -25°C ~ 50°C 9.6 VDC 1.2 VDC
CA3KN22MD Schneider Electric

CA3KN22MD

K CONTROL RELAY 2NO 2NC 220VDC C

Schneider Electric

1,519 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 220VDC 4PST-2NO/2NC (2 Form A, 2 Form B) 10 A 690VAC - Max - Screw Terminal -25°C ~ 50°C 176 VDC 22 VDC
Total 1819 Record«Prev1... 1819202122232425...182Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Contactors (Electromechanical)?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Contactors (Electromechanical) FAQ

Common questions about filtering, comparing and sourcing Contactors (Electromechanical) components.

How can I narrow the Contactors (Electromechanical) selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Contactors (Electromechanical) part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.