Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Contactors (Electromechanical)

Use the filters and product table below to compare Contactors (Electromechanical) components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Features Termination Style Operating Temperature Must Operate Voltage Must Release Voltage
GX14CAB Sensata-Gigavac Clean Energy

GX14CAB

GX SERIES POWER CONTACTOR

Sensata-Gigavac Clean Energy

1,947 -
Datasheet GX14 Bulk Active Chassis Mount 24VDC SPST-NO (DM) (1 Form X) 350 A 800VDC - Max Auxiliary Contacts, Sealed - Hermetically Stud, Wire Leads -55°C ~ 85°C 16 VDC 2 VDC
GX21CBB Sensata-Gigavac Clean Energy

GX21CBB

GX SERIES POWER CONTACTOR

Sensata-Gigavac Clean Energy

1,851 -
Datasheet GX21 Bulk Active Chassis Mount 24VDC SPST-NO (DM) (1 Form X) 150 A 800VDC - Max Auxiliary Contacts, Sealed - Hermetically Stud, Wire Leads -55°C ~ 85°C 16 VDC 0.5 VDC
GV200CBB-1 Sensata-Gigavac Clean Energy

GV200CBB-1

GV SERIES POWER CONTACTOR

Sensata-Gigavac Clean Energy

2,890 -
Datasheet GV200 Bulk Active Chassis Mount 24VDC SPST-NO (DM) (1 Form X) 500 A 800VDC - Max Auxiliary Contacts, Sealed - Hermetically Stud, Wire Leads -55°C ~ 85°C 16 VDC 2 VDC
GX46CDB Sensata-Gigavac Clean Energy

GX46CDB

GX SERIES POWER CONTACTOR

Sensata-Gigavac Clean Energy

1,025 -
Datasheet GX46 Bulk Active Chassis Mount 24VDC SPST-NO (DM) (1 Form X) 600 A 800VDC - Max Auxiliary Contacts, Sealed - Hermetically Screw Terminal -55°C ~ 85°C 16 VDC 0.5 VDC
P125FDA Sensata-Gigavac Clean Energy

P125FDA

P SERIES CONTACTOR

Sensata-Gigavac Clean Energy

4,934 -
Datasheet P125 Bulk Active Chassis Mount 48VDC SPST-NO (DM) (1 Form X) 30 A 1200VDC - Nom Sealed - Hermetically Stud -40°C ~ 65°C 30 VDC 0.8 VDC
PNC113FDA Sensata-Gigavac Clean Energy

PNC113FDA

P SERIES CONTACTOR

Sensata-Gigavac Clean Energy

2,096 -
Datasheet PNC113 Bulk Active Chassis Mount 48VDC SPST-NC (DB) (1 Form Y) 30 A 1500VDC - Nom Sealed - Hermetically Stud -40°C ~ 65°C 30 VDC 0.8 VDC
P105FDA Sensata-Gigavac Clean Energy

P105FDA

P SERIES CONTACTOR

Sensata-Gigavac Clean Energy

1,850 -
Datasheet P105 Bulk Active Chassis Mount 48VDC SPST-NO (DM) (1 Form X) 50 A 1200VDC - Nom Sealed - Hermetically Stud -40°C ~ 65°C 30 VDC 0.8 VDC
GV124FPX Sensata-Gigavac Clean Energy

GV124FPX

GV SERIES POWER CONTACTOR

Sensata-Gigavac Clean Energy

2,029 -
Datasheet GV12 Bulk Active Chassis Mount 48VDC SPST-NO (DM) (1 Form X) 200 A 100VDC - Nom Sealed - Hermetically PC Pins -55°C ~ 85°C 28 VDC 1.8 VDC
GV124BPX Sensata-Gigavac Clean Energy

GV124BPX

GV SERIES POWER CONTACTOR

Sensata-Gigavac Clean Energy

4,068 -
Datasheet GV12 Bulk Active Chassis Mount 12VDC SPST-NO (DM) (1 Form X) 200 A 100VDC - Nom Sealed - Hermetically PC Pins -55°C ~ 85°C 8 VDC 0.5 VDC
GV124CPX Sensata-Gigavac Clean Energy

GV124CPX

GV SERIES POWER CONTACTOR

Sensata-Gigavac Clean Energy

1,263 -
Datasheet GV12 Bulk Active Chassis Mount 24VDC SPST-NO (DM) (1 Form X) 200 A 100VDC - Nom Sealed - Hermetically PC Pins -55°C ~ 85°C 16 VDC 0.5 VDC
Total 800 Record«Prev1... 910111213141516...80Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Contactors (Electromechanical)?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Contactors (Electromechanical) FAQ

Common questions about filtering, comparing and sourcing Contactors (Electromechanical) components.

How can I narrow the Contactors (Electromechanical) selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Contactors (Electromechanical) part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.