Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Contactors (Electromechanical)

Use the filters and product table below to compare Contactors (Electromechanical) components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Features Termination Style Operating Temperature Must Operate Voltage Must Release Voltage
CC9SA208-60HZ Carlo Gavazzi Inc.

CC9SA208-60HZ

RLY CONT 3P 208V 60HZ 1NO/1NC

Carlo Gavazzi Inc.

2,598 -
Datasheet CC Box Active Chassis Mount, DIN Rail 208VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 176.8 VAC 62.4 VAC
CC9SA600-60HZ Carlo Gavazzi Inc.

CC9SA600-60HZ

RLY CONT 3P 600V 60HZ 1NO/1NC

Carlo Gavazzi Inc.

2,638 -
Datasheet CC Box Active Chassis Mount, DIN Rail 600VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 510 VAC 180 VAC
CGMS-12D-24L-10 Carlo Gavazzi Inc.

CGMS-12D-24L-10

THREE POLE MINIATURE STYLE 12AMP

Carlo Gavazzi Inc.

4,397 -
Datasheet CGMS Bulk Active Chassis Mount 24VDC 3PST-NO (3 Form A) 12 A 440VAC - Max Auxiliary Contacts Screw Terminal - - -
CC9SA220 Carlo Gavazzi Inc.

CC9SA220

RLY CONT 3P 220V 50/60HZ 1NO/1NC

Carlo Gavazzi Inc.

1,072 -
Datasheet CC Box Active Chassis Mount, DIN Rail 220VAC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 187 VAC 66 VAC
CC9SD12 Carlo Gavazzi Inc.

CC9SD12

RLY CONT 3P 12V DC 1NO/1NC

Carlo Gavazzi Inc.

3,616 -
Datasheet CC Box Active Chassis Mount, DIN Rail 12VDC 3PST-NO (3 Form A) 9 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 8.4 VDC 1.2 VDC
CC12SA110 Carlo Gavazzi Inc.

CC12SA110

RLY CONT 3P 110V 50/60HZ 1NO/1NC

Carlo Gavazzi Inc.

4,330 -
Datasheet CC Bulk Active Chassis Mount, DIN Rail 110VAC 3PST-NO (3 Form A) 12 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 93.5 VAC 33 VAC
CC12SA208-60HZ Carlo Gavazzi Inc.

CC12SA208-60HZ

RLY CONT 3P 208V 60HZ 1NO/1NC

Carlo Gavazzi Inc.

3,081 -
Datasheet CC Bulk Active Chassis Mount, DIN Rail 208VAC 3PST-NO (3 Form A) 12 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 176.8 VAC 62.4 VAC
CC12SA480-60HZ Carlo Gavazzi Inc.

CC12SA480-60HZ

RLY CONT 3P 480V 60HZ 1NO/1NC

Carlo Gavazzi Inc.

1,415 -
Datasheet CC Bulk Active Chassis Mount, DIN Rail 480VAC 3PST-NO (3 Form A) 12 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 408 VAC 144 VAC
CC12SA600-60HZ Carlo Gavazzi Inc.

CC12SA600-60HZ

RLY CONT 3P 600V 60HZ 1NO/1NC

Carlo Gavazzi Inc.

4,833 -
Datasheet CC Bulk Active Chassis Mount, DIN Rail 600VAC 3PST-NO (3 Form A) 12 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 510 VAC 180 VAC
CC12SA24 Carlo Gavazzi Inc.

CC12SA24

RLY CONT 3P 24V 50/60HZ 1NO/1NC

Carlo Gavazzi Inc.

1,153 -
Datasheet CC Bulk Active Chassis Mount, DIN Rail 24VAC 3PST-NO (3 Form A) 12 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 60°C 20.4 VAC 7.2 VAC
Total 397 Record«Prev1... 1112131415161718...40Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Contactors (Electromechanical)?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Contactors (Electromechanical) FAQ

Common questions about filtering, comparing and sourcing Contactors (Electromechanical) components.

How can I narrow the Contactors (Electromechanical) selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Contactors (Electromechanical) part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.