| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
ECSNOASPPWR SENSOR,CURR,SS,NO,SPL,ADJ,W/ |
3,943 | - |
|
Datasheet | ECS | Module, Single Pass Through | Bulk | Active | AC/DC | Current Switch | 150A | 1 | Current | - | DC | - | - | - | - | - | -50°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
ECSJ402SPPWR SENSOR,CURR,NO,AC OUT,SPL,1. |
4,712 | - |
|
Datasheet | ECSJ | Module, Single Pass Through | Bulk | Active | DC | Current Switch | 200A | 1 | Current | - | DC, 40Hz ~ 100Hz | - | ±1% | - | 100ms | 200A | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
ECSTD401SCPWR SENSOR,CURR TD,NO,SOL,1-175A |
2,732 | - |
|
Datasheet | ECS | Module, Single Pass Through | Bulk | Active | AC | Current Switch | 175A | 1 | Current | - | - | - | - | - | - | - | -15°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
ECSJ404SCPWR SENSOR,CURR,NO,AC OUT,SOL,AD |
2,523 | - |
|
Datasheet | ECSJ | Module, Single Pass Through | Bulk | Active | DC | Current Switch | 175A | 1 | Current | - | DC, 40Hz ~ 100Hz | - | ±1% | 120V | 100ms | 200A | -20°C ~ 50°C | - | - | Unidirectional | Chassis Mount | - |
|
1510390000CONDITIONER SIGNAL RAIL MNT |
3,561 | - |
|
Datasheet | - | Box | Bulk | Active | AC/DC | Current Switch | 60A | 1 | Relay, SPDT | - | - | - | ±1.5% | 16.8V ~ 31.2V | 300ms | - | -25°C ~ 60°C | - | - | Bidirectional | DIN Rail | - |
|
EAC110SPPWR SENSOR,CURRENT,SPLIT,AC,0-10 |
3,419 | - |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
EAC1420SCPWR SENSOR,CURRENT,SOLID,4-20MA, |
4,529 | - |
|
Datasheet | EAC | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
IVT-3-1K-U3-I-CAN2-24CURRENT SENSOR - ISA-SCALE IVT 3 |
3,388 | - |
|
Datasheet | - | - | Tray | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
EAC2420SPPWR SENSOR,CURRENT,SPLIT,4-20MA, |
2,353 | - |
|
Datasheet | EAC | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
EAC1420SPPWR SENSOR,CURRENT,SPLIT,4-20MA, |
4,601 | - |
|
Datasheet | EAC | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
IVT-3-1K-U6-I-CAN2-24CURRENT SENSOR - ISA-SCALE IVT 3 |
2,948 | - |
|
Datasheet | - | - | Tray | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
EVT4-420-24LPWR SENSOR,AC VOLTAGE,480 MAX IN |
3,935 | - |
|
Datasheet | CurrentWatch | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
EGFL2NCLAT3PWR SENSOR,GFI,2"AP,NC FM B REL, |
1,834 | - |
|
Datasheet | EGF | Module, Single Pass Through | Bulk | Active | AC/DC | Current Switch | 1A, 2A (Selectable) | 1 | Current | - | DC | - | - | 24V | - | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
DW500UB-2V10 MHZ CURRENT TRANSDUCER 500A |
3,617 | - |
|
Datasheet | DW | Module, Single Pass Through | Box | Active | AC/DC | Closed Loop | 500A | 1 | Analog Voltage | - | DC ~ 10MHz | 0.001% | - | 85V ~ 265V | 1µs | - | -30°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
EDC210SPPWR SENSOR,CURR,SPL,DC,10VDC,100 |
4,363 | - |
|
Datasheet | EDC | Module, Single Pass Through | Bulk | Active | AC/DC | Current Transducer | 100A | 1 | Current | - | DC | - | ±2% | 24V | - | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
ECS701SCPWR SENSOR,CURR,NO,SOL,1.5-150A, |
3,316 | - |
|
Datasheet | CurrentWatch | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
EDC1420SCPWR SENSOR,CURR,SOL,DC,4-20MA,5- |
2,490 | - |
|
Datasheet | EDC | Module, Single Pass Through | Bulk | Active | AC/DC | Current Transducer | 20A | 1 | Current | - | DC | - | ±1% | 24V | - | - | -20°C ~ 50°C | - | - | Bidirectional | Chassis Mount | - |
|
EACR1420SPPWR SENSOR,CURR,ACRMS,SPL,4-20MA |
1,504 | - |
|
Datasheet | * | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
EVT1-420-24LPWR SENSOR,AC VOLTAGE,120 MAX IN |
3,048 | - |
|
Datasheet | EVT | Module, Single Pass Through | Bulk | Active | AC | Current Sensor | - | 1 | Current | - | - | - | - | 110VAC | - | - | -30°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
TMCS1123D71QDVGR1300V REINFORCED ISOLATION, 80AR |
1,728 | - |
|
Datasheet | * | - | Tape & Reel (TR) | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Current Sensors FAQ
Common questions about selecting, comparing and sourcing Current Sensors components through Winsun (HK) Electronics.
What should I check when selecting Current Sensors components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Current Sensors part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Current Sensors parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Current Sensors components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.