Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Current Sensors

Use the filters and product table below to compare Current Sensors components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
CSLA2EL Honeywell Sensing and Productivity Solutions

CSLA2EL

SENSOR CURRENT HALL 550A AC/DC

Honeywell Sensing and Productivity Solutions

4,376 -
Datasheet CSLA Module, Single Pass Through Bulk Obsolete AC/DC Hall Effect, Open Loop 550A 1 Ratiometric, Voltage 4.3mV/N - - - 6V ~ 12V 3µs 20mA -25°C ~ 85°C - - Bidirectional Through Hole -
CSNG251-001 Honeywell Sensing and Productivity Solutions

CSNG251-001

SENSOR CURRENT HALL 200A AC/DC

Honeywell Sensing and Productivity Solutions

2,805 -
Datasheet CSN Module, Single Pass Through Bulk Active AC/DC Hall Effect, Closed Loop 200A 1 Ratiometric, Current - - - ±0.5% ±15V 0.5µs 10mA -40°C ~ 85°C - - Bidirectional Through Hole -
CSLA2EN Honeywell Sensing and Productivity Solutions

CSLA2EN

SENSOR CURRENT HALL 950A AC/DC

Honeywell Sensing and Productivity Solutions

4,013 -
Datasheet CSLA Module, Single Pass Through Bulk Obsolete AC/DC Hall Effect, Open Loop 950A 1 Ratiometric, Voltage 2.3mV/N - - - 6V ~ 12V 3µs 20mA -25°C ~ 85°C - - Bidirectional Through Hole -
CSLA2EM Honeywell Sensing and Productivity Solutions

CSLA2EM

SENSOR CURRENT HALL 765A AC/DC

Honeywell Sensing and Productivity Solutions

3,919 -
Datasheet CSLA Module, Single Pass Through Bulk Obsolete AC/DC Hall Effect, Open Loop 765A 1 Ratiometric, Voltage 3.1mV/N - - - 6V ~ 12V 3µs 20mA -25°C ~ 85°C - - Bidirectional Through Hole -
CSSV1500N-156 Honeywell Sensing and Productivity Solutions

CSSV1500N-156

CSSV1500N SERIES CLOSED LOOP CUR

Honeywell Sensing and Productivity Solutions

2,500 -
Datasheet CSSV1500 Module, Single Pass Through Box Active AC/DC Current Sensor 1500A 1 CAN Bus - DC, 50Hz ~ 60Hz - ±0.5% 6V ~ 18V - 200mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
CSSV1500N-155R Honeywell Sensing and Productivity Solutions

CSSV1500N-155R

CSSV1500N SERIES CLOSED LOOP CUR

Honeywell Sensing and Productivity Solutions

2,605 -
Datasheet CSSV1500 Module, Single Pass Through Box Active AC/DC Current Sensor 1500A 1 CAN Bus - DC, 50Hz ~ 60Hz - ±0.5% 6V ~ 18V - 200mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
CSSV1500N-154R Honeywell Sensing and Productivity Solutions

CSSV1500N-154R

CSSV1500N SERIES CLOSED LOOP CUR

Honeywell Sensing and Productivity Solutions

4,527 -
Datasheet CSSV1500 Module, Single Pass Through Box Active AC/DC Current Sensor 1500A 1 CAN Bus - DC, 50Hz ~ 60Hz - ±0.5% 6V ~ 18V - 200mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
CSSV1500N-156R Honeywell Sensing and Productivity Solutions

CSSV1500N-156R

CSSV1500N SERIES CLOSED LOOP CUR

Honeywell Sensing and Productivity Solutions

1,819 -
Datasheet CSSV1500 Module, Single Pass Through Box Active AC/DC Current Sensor 1500A 1 CAN Bus - DC, 50Hz ~ 60Hz - ±0.5% 6V ~ 18V - 200mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
CSLA1EL Honeywell Sensing and Productivity Solutions

CSLA1EL

SENSOR CURRENT HALL 625A AC/DC

Honeywell Sensing and Productivity Solutions

3,047 -
Datasheet CSLA Module, Single Pass Through Bulk Obsolete AC/DC Hall Effect, Open Loop 625A 1 Ratiometric, Voltage 5.6mV/N - - - 8V ~ 16V 3µs 19mA -25°C ~ 85°C - - Bidirectional Through Hole -
CSNS300M-002S Honeywell Sensing and Productivity Solutions

CSNS300M-002S

300 AMPS CURRENT SENSOR 4PIN INV

Honeywell Sensing and Productivity Solutions

4,946 -
Datasheet * - Bulk Active - - - - - - - - - - - - - - - - - -
Total 188 Record«Prev1... 111213141516171819Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Current Sensors?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about filtering, comparing and sourcing Current Sensors components.

How can I narrow the Current Sensors selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Current Sensors part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.