| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LA 305-SSENSOR CURRENT HALL 300A AC/DC |
4,725 | - |
|
Datasheet | LA | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.8% | ±12V ~ 15V | 1µs | 140mA | 0°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
APR 400 B420LSENSOR CURRENT 200A, 300A, 400A |
2,875 | - |
|
Datasheet | APR | Module | Bulk | Active | AC | Transformer w/Conditioning | 200A, 300A, 400A (Selectable) | 1 | Ratiometric, 4mA ~ 20mA | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 12V ~ 24V | 400ms | 25mA | -20°C ~ 60°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-SC/L, ASIC 1000A PANEL MOUNT |
3,942 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Ratiometric, Current | 0.2mA/A | 200kHz | ±0.15% | ±0.2% | 14.25V ~ 25.2V | 0.5µs | 49mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
LF 505-SSENSOR CURRENT HALL 500A AC/DC |
112 | - |
|
Datasheet | LF | Module | Tray | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Current | - | DC ~ 100kHz | ±0.1% | ±0.6% | ±15V ~ 24V | 1µs | 124mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
|
DHR 100 C10SENSOR CURRENT HALL 100A AC/DC |
4,825 | - |
|
Datasheet | DHR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Ratiometric, 0V ~ 10V | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Panel Mount | - |
|
|
DHR 200 C420SENSOR CURRENT HALL 200A AC/DC |
3,949 | - |
|
Datasheet | DHR | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Ratiometric, 4mA ~ 20mA | - | DC ~ 6kHz | ±1% | ±1% | 20V ~ 50V | 150ms | 30mA | -40°C ~ 70°C | - | - | Bidirectional | Panel Mount | - |
|
|
LF 2010-SC/L, ASIC 2000A PANEL MOUNT |
3,099 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 2000A | 1 | Ratiometric, Current | 0.2mA/A | 150kHz | ±0.1% | ±0.2% | 14.25V ~ 25.2V | 0.5µs | 48mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
GO 20 SMS/SP3CURRENT TRANSDUCER INTGRATED PRI |
5,896 | - |
|
Datasheet | GO-SMS/SP3 | 16-SOIC (0.295", 7.50mm Width) | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 20A | 1 | Ratiometric, Voltage | 25mV/A | DC ~ 300kHz | ±0.3% | ±1.3% | 3.135V ~ 3.465V | 2µs | 26mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | - |
|
GO 10-SMS/SP3CURRENT TRANSDUCER INTGRATED PRI |
5,597 | - |
|
Datasheet | GO-SMS/SP3 | 16-SOIC (0.295", 7.50mm Width) | Tape & Reel (TR) | Active | AC/DC | Hall Effect | 10A | 1 | Ratiometric, Voltage | 50mV/A | DC ~ 300kHz | ±0.3% | ±1.3% | 3.135V ~ 3.465V | 2µs | 26mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | - |
|
HMSR 15-SMSSURFACT MT, 15A SENSOR WITH HIGH |
907 | - |
|
Datasheet | HMSR | 16-PowerSOIC (0.295", 7.50mm Width), 10 Leads | Tape & Reel (TR) | Active | AC/DC | Hall Effect, Open Loop | 15A | 1 | Ratiometric, Voltage | 53.33mV/A | 300kHz | ±0.5% | - | 4.5V ~ 5.5V | - | 26mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | - |
Current Sensors FAQ
Common questions about filtering, comparing and sourcing Current Sensors components.
How can I narrow the Current Sensors selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Current Sensors part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.