Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Current Sensors

Use the filters and product table below to compare Current Sensors components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
2814359 Phoenix Contact

2814359

CURRENT MEASURING TRANSDUCER

Phoenix Contact

4,821 -
Datasheet - Module Bulk Active AC Transformer w/Conditioning 1A, 5A (Selectable) 1 Ratiometric, 0V ~ 10V, 0 ~ 20mA - 45Hz ~ 60Hz - - - - - -25°C ~ 65°C - - Bidirectional DIN Rail -
2904921 Phoenix Contact

2904921

PACT RCP-4000A-1A-D95

Phoenix Contact

1,292 -
Datasheet - Module Bulk Active AC Transformer w/Conditioning 100A ~ 4000A (Selectable) 1 Ratiometric, Voltage - 10Hz ~ 5kHz ±0.5% ±1% 24V - - 20°C ~ 70°C - - Bidirectional DIN Rail -
1136504 Phoenix Contact

1136504

SENSOR CURRENT HALL 11A AC/DC

Phoenix Contact

3,453 -
Datasheet - Module Bulk Active AC/DC Current Transducer 1A, 5A, 10A (Selectable) 1 Analog Voltage - DC, 10Hz ~ 1kHz - - 9.6V ~ 30V 200ms - -40°C ~ 60°C - - Bidirectional DIN Rail -
1136513 Phoenix Contact

1136513

SENSOR CURRENT HALL 55A AC/DC

Phoenix Contact

2,750 -
Datasheet - Module Bulk Active AC/DC Current Transducer 50A 1 Analog Voltage - DC, 10Hz ~ 1kHz - - 9.6V ~ 30V 200ms - -40°C ~ 60°C - - Bidirectional DIN Rail -
1698164 Phoenix Contact

1698164

SENSOR CURRENT HALL 11A AC/DC

Phoenix Contact

2,032 -
Datasheet - Module Bulk Active AC/DC Current Transducer 1A, 5A, 10A (Selectable) 1 Analog Voltage - DC, 10Hz ~ 1kHz - - 9.6V ~ 30V 200ms - -40°C ~ 60°C - - Bidirectional DIN Rail -
1698172 Phoenix Contact

1698172

SENSOR CURRENT HALL 55A AC/DC

Phoenix Contact

2,571 -
Datasheet - Module Bulk Active AC/DC Current Transducer 50A 1 Analog Voltage - DC, 10Hz ~ 1kHz - - 9.6V ~ 30V 200ms - -40°C ~ 60°C - - Bidirectional DIN Rail -
2814647 Phoenix Contact

2814647

SENSOR CURRENT HALL 55A AC/DC

Phoenix Contact

4,285 -
Datasheet - Module Bulk Obsolete AC/DC Hall Effect, Open Loop 55A 1 Ratiometric, Voltage and Current - 15Hz ~ 400Hz - ±0.5% 20V ~ 30V 330ms (AC), 40ms (DC) 40mA -20°C ~ 60°C - - Bidirectional DIN Rail -
2814634 Phoenix Contact

2814634

SENSOR CURRENT HALL 11A AC/DC

Phoenix Contact

3,303 -
Datasheet - Module Bulk Obsolete AC/DC Hall Effect, Open Loop 11A 1 Ratiometric, Voltage and Current - 15Hz ~ 400Hz - ±0.5% 20V ~ 30V 330ms (AC), 40ms (DC) 40mA -20°C ~ 60°C - - Bidirectional DIN Rail -
2814744 Phoenix Contact

2814744

SENSOR CURRENT HALL 55A AC/DC

Phoenix Contact

3,360 -
Datasheet - Module Bulk Obsolete AC/DC Hall Effect, Open Loop 55A 1 Ratiometric, Voltage and Current - 15Hz ~ 400Hz - ±0.5% 20V ~ 30V 330ms (AC), 40ms (DC) 50mA -20°C ~ 60°C - - Bidirectional DIN Rail -
2814650 Phoenix Contact

2814650

SENSOR CURRENT HALL 11A AC/DC

Phoenix Contact

3,892 -
Datasheet - Module Bulk Obsolete AC/DC Hall Effect, Open Loop 11A 1 Ratiometric, Voltage and Current - 15Hz ~ 400Hz - ±0.5% 20V ~ 30V 330ms (AC), 40ms (DC) 50mA -20°C ~ 60°C - - Bidirectional DIN Rail -
Total 21 Record«Prev123Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Current Sensors?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about filtering, comparing and sourcing Current Sensors components.

How can I narrow the Current Sensors selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Current Sensors part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.