Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Current Sensors

Use the filters and product table below to compare Current Sensors components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
L18P003S05 Tamura

L18P003S05

SENSOR CURRENT HALL 3A AC/DC

Tamura

3,321 -
Datasheet L18PXXXS05 Module Bulk Active AC/DC Hall Effect, Open Loop 3A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 5V 5µs 15mA -30°C ~ 80°C - - Bidirectional Through Hole -
L18P040S05R Tamura

L18P040S05R

SENSOR CURRENT HALL 40A AC/DC

Tamura

4,626 -
Datasheet L18PXXXS05 Module Bulk Active AC/DC Hall Effect, Open Loop 40A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 5V 5µs 15mA -30°C ~ 80°C - - Bidirectional Through Hole -
L18P005S05 Tamura

L18P005S05

SENSOR CURRENT HALL 5A AC/DC

Tamura

4,718 -
Datasheet L18PXXXS05 Module Bulk Active AC/DC Hall Effect, Open Loop 5A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 5V 5µs 15mA -30°C ~ 80°C - - Bidirectional Through Hole -
L18P003S12 Tamura

L18P003S12

SENSOR CURRENT HALL 3A AC/DC

Tamura

4,715 -
Datasheet L18PXXXS12 Module Bulk Active AC/DC Hall Effect, Open Loop 3A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 12V 5µs 15mA -30°C ~ 80°C - - Bidirectional Through Hole -
L18P050S05R Tamura

L18P050S05R

SENSOR CURRENT HALL 50A AC/DC

Tamura

2,966 -
Datasheet L18PXXXS05 Module Bulk Active AC/DC Hall Effect, Open Loop 50A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 5V 5µs 15mA -30°C ~ 80°C - - Bidirectional Through Hole -
L18P005S12 Tamura

L18P005S12

SENSOR CURRENT HALL 5A AC/DC

Tamura

1,906 -
Datasheet L18PXXXS12 Module Bulk Active AC/DC Hall Effect, Open Loop 5A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 12V 5µs 15mA -30°C ~ 80°C - - Bidirectional Through Hole -
L18P060S05R Tamura

L18P060S05R

SENSOR CURRENT HALL 60A AC/DC

Tamura

2,144 -
Datasheet L18PXXXS05 Module Bulk Active AC/DC Hall Effect, Open Loop 60A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 5V 5µs 15mA -30°C ~ 80°C - - Bidirectional Through Hole -
L08P100D15M1 Tamura

L08P100D15M1

SENSOR CURRENT HALL 100A AC/DC

Tamura

4,402 -
Datasheet - Module, Single Pass Through Bulk Active AC/DC Hall Effect, Open Loop 100A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - ±15V 10µs 12mA -10°C ~ 80°C - - Bidirectional Through Hole -
L08P200D15W Tamura

L08P200D15W

SENSOR CURRENT HALL 200A AC/DC

Tamura

2,581 -
Datasheet - Module, Single Pass Through Bulk Active AC/DC Hall Effect, Open Loop 200A 1 Ratiometric, Voltage - - ±1% - 15V 50µs 20mA -20°C ~ 80°C - - Bidirectional Through Hole -
L08P150D15M1 Tamura

L08P150D15M1

SENSOR

Tamura

2,699 -
Datasheet - Module Tray Active AC/DC Hall Effect, Open Loop 150A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 15V 10µs 12mA -10°C ~ 80°C - - Bidirectional Through Hole -
Total 377 Record«Prev1... 910111213141516...38Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Current Sensors?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about filtering, comparing and sourcing Current Sensors components.

How can I narrow the Current Sensors selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Current Sensors part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.