Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Current Sensors

Use the filters and product table below to compare Current Sensors components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
L37S300D15M Tamura

L37S300D15M

SENSOR

Tamura

157 -
Datasheet L37S D155 Module Tray Active DC Hall Effect, Open Loop 300A 1 Ratiometric, Voltage - - ±1% - 15V 3µs 20mA -40°C ~ 85°C - - Unidirectional Chassis Mount -
LA37S050S05KM Tamura

LA37S050S05KM

CURRENT SENSOR (50A; 5V) -40 105

Tamura

145 -
Datasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 50A 1 Analog Voltage 12.5mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 3.5µs 23mA -40°C ~ 105°C - - - Chassis Mount -
LA37S100S05KM Tamura

LA37S100S05KM

CURRENT SENSOR (100A; 5V) -40 10

Tamura

142 -
Datasheet LA37S S05K Module, Single Pass Through Tray Active DC Open Loop 100A 1 Analog Voltage 6.25mV/A 100kHz ±0.5% ±1.8% 4.5V ~ 5.5V 3.5µs 23mA -40°C ~ 105°C - - - Chassis Mount -
L34S500D15T Tamura

L34S500D15T

CURRENT SENSOR (500A; 15V)

Tamura

115 -
Datasheet L34S D15T Module, Single Pass Through Tray Active AC/DC Hall Effect, Open Loop 500A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.5% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L18P050D15-OP Tamura

L18P050D15-OP

CURRENT SENSOR (50A; 15V)

Tamura

697 -
Datasheet L18PXXXD15 Module Tray Active AC/DC Hall Effect, Open Loop 50A 1 Ratiometric, Voltage - - ±1% - ±12V ~ 15V 5µs 18mA -30°C ~ 80°C - - Bidirectional Through Hole -
L18P003D15-OP Tamura

L18P003D15-OP

CURRENT SENSOR (3A; 15V)

Tamura

442 -
Datasheet L18PXXXD15 Module Tray Active AC/DC Hall Effect, Open Loop 3A 1 Ratiometric, Voltage - - ±1% - ±12V ~ 15V 5µs 18mA -30°C ~ 80°C - - Bidirectional Through Hole -
L18P010D15-OP Tamura

L18P010D15-OP

CURRENT SENSOR (10A; 15V)

Tamura

589 -
Datasheet L18PXXXD15 Module Tray Active AC/DC Hall Effect, Open Loop 10A 1 Ratiometric, Voltage - - ±1% - ±12V ~ 15V 5µs 18mA -30°C ~ 80°C - - Bidirectional Through Hole -
F02P015S05L Tamura

F02P015S05L

SENSOR

Tamura

352 -
Datasheet F02P Module Tray Active AC Flux Gate, Closed Loop 15A 1 Ratiometric, Voltage 41.67mV/A 300kHz ±1% ±1.2% 5V 0.3µs 30mA -40°C ~ 105°C - - Bidirectional Through Hole -
L18P020S05 Tamura

L18P020S05

SENSOR CURRENT HALL 20A AC/DC

Tamura

211 -
Datasheet L18PXXXS05 Module Bulk Active AC/DC Hall Effect, Open Loop 20A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - 5V 5µs 15mA -30°C ~ 80°C - - Bidirectional Through Hole -
F03P006S05L Tamura

F03P006S05L

SENSOR

Tamura

405 -
Datasheet F03P Module Tray Active AC Flux Gate, Closed Loop 6A 1 Ratiometric, Voltage 104.2mV/A 300kHz ±0.1% - 4.75V ~ 5.25V 0.3µs 25mA -40°C ~ 105°C - - Bidirectional Through Hole -
Total 377 Record«Prev12345...38Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Current Sensors?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about filtering, comparing and sourcing Current Sensors components.

How can I narrow the Current Sensors selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Current Sensors part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.