Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Current Sensors

Use the filters and product table below to compare Current Sensors components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
L32P200S05FS Tamura

L32P200S05FS

SENSOR CURRENT HALL 200A AC/DC

Tamura

1,732 -
Datasheet - Module, Single Pass Through Bulk Active AC/DC Hall Effect, Open Loop 200A 1 Ratiometric, Voltage - DC ~ 50kHz ±0.5% - 5V 5µs 15mA -40°C ~ 85°C - - Bidirectional Through Hole -
L03S200D15 Tamura

L03S200D15

SENSOR CURRENT HALL 200A AC/DC

Tamura

1,721 -
Datasheet - Module Bulk Obsolete AC/DC Hall Effect, Open Loop 200A 1 Ratiometric, Voltage - DC ~ 50kHz ±1% ±1% ±15V 5µs 12mA -20°C ~ 80°C - - Bidirectional Through Hole -
L03S300D15 Tamura

L03S300D15

SENSOR CURRENT HALL 300A AC/DC

Tamura

2,407 -
Datasheet - Module Bulk Obsolete AC/DC Hall Effect, Open Loop 300A 1 Ratiometric, Voltage - DC ~ 50kHz ±1% ±1% ±15V 5µs 12mA -20°C ~ 80°C - - Bidirectional Through Hole -
L32P300S05FS Tamura

L32P300S05FS

SENSOR CURRENT HALL 300A AC/DC

Tamura

1,873 -
Datasheet - Module, Single Pass Through Bulk Active AC/DC Hall Effect, Open Loop 300A 1 Ratiometric, Voltage - DC ~ 50kHz ±0.5% - 5V 5µs 15mA -40°C ~ 85°C - - Bidirectional Through Hole -
L03S400D15 Tamura

L03S400D15

SENSOR CURRENT HALL 400A AC/DC

Tamura

3,103 -
Datasheet - Module Bulk Obsolete AC/DC Hall Effect, Open Loop 400A 1 Ratiometric, Voltage - DC ~ 50kHz ±1% ±1% ±15V 5µs 12mA -20°C ~ 80°C - - Bidirectional Through Hole -
L37S050D15M Tamura

L37S050D15M

SENSOR

Tamura

3,084 -
Datasheet L37S D155 Module Tray Active DC Hall Effect, Open Loop 150A 1 Ratiometric, Voltage - - ±1% - 15V 3µs 20mA -40°C ~ 85°C - - Unidirectional Chassis Mount -
L37S050S05J Tamura

L37S050S05J

CURRENT SENSOR (50A; +5V)

Tamura

1,110 -
Datasheet L37S S05 Module, Single Pass Through Tray Active DC Hall Effect, Open Loop 50A 1 Ratiometric, Voltage - DC ~ 50kHz ±1% - 4.75V ~ 5.25V 5µs 20mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
L37S050D15J Tamura

L37S050D15J

CURRENT SENSOR (50A; 15V)

Tamura

3,300 -
Datasheet L37S D15 Module, Single Pass Through Tray Active AC/DC Hall Effect, Open Loop 50A 1 Ratiometric, Voltage - - ±1% - ±12V ~ 15V 3µs 20mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
L05Z800S15 Tamura

L05Z800S15

SENSOR CURRENT HALL 800A AC/DC

Tamura

4,170 -
Datasheet - Module Bulk Active AC/DC Hall Effect, Open Loop 800A 1 Ratiometric, Voltage - DC ~ 100kHz ±1% - ±15V 10µs 20mA -40°C ~ 85°C - - Bidirectional Panel Mount -
L03S500D15 Tamura

L03S500D15

SENSOR CURRENT HALL 500A AC/DC

Tamura

1,952 -
Datasheet - Module Bulk Obsolete AC/DC Hall Effect, Open Loop 500A 1 Ratiometric, Voltage - DC ~ 50kHz ±1% ±1% ±15V 5µs 12mA -20°C ~ 80°C - - Bidirectional Through Hole -
Total 377 Record«Prev1... 2021222324252627...38Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Current Sensors?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about filtering, comparing and sourcing Current Sensors components.

How can I narrow the Current Sensors selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Current Sensors part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.