Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Current Sensors

Use the filters and product table below to compare Current Sensors components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
S27S300D15Y Tamura

S27S300D15Y

SENSOR CURRENT HALL 300A AC/DC

Tamura

2,760 -
Datasheet - Module, Single Pass Through Bulk Active AC/DC Hall Effect, Closed Loop 300A 1 Ratiometric, Current - DC ~ 100kHz ±0.1% ±0.4% ±12V ~ 20V 1µs 20mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
L40S200D15M Tamura

L40S200D15M

CURRENT SENSOR (200A; 15V) -40 1

Tamura

1,174 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 200A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L40S200D15J Tamura

L40S200D15J

CURRENT SENSOR (200A; 15V) -40 1

Tamura

4,899 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 200A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L40S400D15J Tamura

L40S400D15J

CURRENT SENSOR (400A; 15V) -40 1

Tamura

3,951 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 400A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L40S400D15M Tamura

L40S400D15M

CURRENT SENSOR (400A; 15V) -40 1

Tamura

2,233 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 400A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L40S500D15J Tamura

L40S500D15J

CURRENT SENSOR (500A; 15V) -40 1

Tamura

1,754 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 500A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L40S500D15M Tamura

L40S500D15M

CURRENT SENSOR (500A; 15V) -40 1

Tamura

1,684 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 500A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L40S600D15M Tamura

L40S600D15M

CURRENT SENSOR (600A; 15V) -40 1

Tamura

3,916 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 600A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L40S600D15J Tamura

L40S600D15J

CURRENT SENSOR (600A; 15V) -40 1

Tamura

4,819 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 600A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
L40S800D15M Tamura

L40S800D15M

CURRENT SENSOR (800A; 15V) -40 1

Tamura

2,812 -
Datasheet L40S D15 Module Tray Active AC/DC Hall Effect, Open Loop 800A 1 Ratiometric, Voltage - DC ~ 25kHz ±0.1% - ±12V ~ 15V 5µs 25mA -40°C ~ 105°C - - Bidirectional Chassis Mount -
Total 377 Record«Prev1... 2829303132333435...38Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Current Sensors?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about filtering, comparing and sourcing Current Sensors components.

How can I narrow the Current Sensors selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Current Sensors part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.