Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
EXPLORE COMPONENTS

Current Sensors

Browse available Current Sensors part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.

For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.

Compare Part Numbers Review available models and manufacturers
Datasheets & Specifications Access technical references quickly
RFQ & BOM Support Send quantities for sourcing and quotation
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
FG-R04-4BA KEMET

FG-R04-4BA

SENSOR CURRENT FLUX 40A IEC VRT

KEMET

147 -
Datasheet FG Module Box Active AC/DC Flux Gate, Open Loop 50mA 1 Ratiometric, Voltage 40V/A DC ~ 55Hz - - 4.75V ~ 5.25V 250ms (AC), 1s (DC) 13mA (Typ) -40°C ~ 105°C - - Bidirectional Through Hole -
FG-R05-4BA KEMET

FG-R05-4BA

SENSOR CURRENT FLUX 40A IEC VRT

KEMET

110 -
Datasheet FG Module, Single Pass Through Box Active AC/DC Flux Gate, Open Loop 50mA 1 Ratiometric, Voltage 40V/A DC ~ 55Hz - - 4.75V ~ 5.25V 250ms (AC), 1s (DC) 13mA (Typ) -40°C ~ 105°C - - Bidirectional Through Hole -
LZSR 200-TP/SP1 LEM USA Inc.

LZSR 200-TP/SP1

CLOSED-LOOP CURRENT SENSOR 200A

LEM USA Inc.

136 -
Datasheet LZSR-TP/SP1 Module Bulk Active AC/DC Closed Loop 200A 1 Voltage 3.125mV/A DC ~ 200kHz ±0.18% - 4.75V ~ 5.25V - - -40°C ~ 85°C - - Bidirectional Through Hole -
RCM01-02 Littelfuse/Western Automation

RCM01-02

RESIDUAL CURRENT MONITOR, 6MA DC

Littelfuse/Western Automation

320 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Through Hole -
RCM14-03_SYS_H Littelfuse/Western Automation

RCM14-03_SYS_H

RCM14-03 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

560 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Through Hole -
RCM14-01_SYS_H Littelfuse/Western Automation

RCM14-01_SYS_H

RCM14-01 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

560 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Chassis Mount -
RCM14-01_SYS_V Littelfuse/Western Automation

RCM14-01_SYS_V

RCM14-01 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

560 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Chassis Mount -
RCM14-03 Littelfuse/Western Automation

RCM14-03

RESIDUAL CURRENT MONITOR, 6MA DC

Littelfuse/Western Automation

155 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - DC ~ 60Hz - - 10.8V ~ 13.2V - 40mA -40°C ~ 85°C - - - Chassis Mount -
RCM14-03_SYS_V Littelfuse/Western Automation

RCM14-03_SYS_V

RCM14-03 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

555 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - DC ~ 60Hz - - 10.8V ~ 13.2V - 40mA -40°C ~ 85°C - - - Through Hole -
HCSP-1BS-0900 Amphenol Piher Sensing Systems

HCSP-1BS-0900

AUTOMOTIVE OPEN LOOP CURRENT SEN

Amphenol Piher Sensing Systems

106 -
Datasheet - Module Bulk Active AC/DC Hall Effect, Open Loop 900A 1 Ratiometric, Voltage 2.22mV/A 70kHz ~ 250kHz - - 4.5V ~ 5.5V 3µs 14mA -40°C ~ 125°C - - Bidirectional Chassis Mount -
RCM20-03 Littelfuse/Western Automation

RCM20-03

RESIDUAL CURRENT MONITOR, 6MA DC

Littelfuse/Western Automation

185 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 10.8V ~ 13.2V - 14.5mA -40°C ~ 85°C - - - Chassis Mount -
RCM20-01 Littelfuse/Western Automation

RCM20-01

RESIDUAL CURRENT MONITOR, 6MA DC

Littelfuse/Western Automation

182 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 6mA 1 - - 50Hz/60Hz - - 12V ~ 24V - 13mA -40°C ~ 85°C - - - Chassis Mount -
HAH3DR 800-S0E LEM USA Inc.

HAH3DR 800-S0E

TRANSDUCER

LEM USA Inc.

4,290 -
Datasheet HAH3DR Module Bulk Active AC/DC Hall Effect, Open Loop 800A 1 Ratiometric, Voltage 2.5mV/A DC ~ 40kHz ±1% ±3.5% 4.75V ~ 5.25V 6µs 60mA -40°C ~ 125°C - - Unidirectional Chassis Mount -
CSNV500M-125 Honeywell Sensing and Productivity Solutions

CSNV500M-125

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

4,421 -
Datasheet CSNV500 Module Box Active AC/DC Hall Effect, Closed Loop 25A 3 CAN Bus - DC ~ 200kHz ±0.1% ±0.24% 4.75V ~ 5.25V 200ns 12mA -40°C ~ 85°C - - Unidirectional Through Hole -
CSNV500M-124 Honeywell Sensing and Productivity Solutions

CSNV500M-124

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

4,288 -
Datasheet CSNV500 Module Box Active AC/DC Hall Effect, Closed Loop 25A 3 CAN Bus - DC ~ 200kHz ±0.1% ±0.24% 4.75V ~ 5.25V 200ns 12mA -40°C ~ 85°C - - Unidirectional Through Hole -
CSNV500N-154 Honeywell Sensing and Productivity Solutions

CSNV500N-154

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

4,857 -
Datasheet CSNV500 Module Box Active AC/DC Hall Effect, Closed Loop 25A 3 CAN Bus - DC ~ 200kHz ±0.1% ±0.24% 4.75V ~ 5.25V 200ns 12mA -40°C ~ 85°C - - Unidirectional Through Hole -
CSNV500M-354M Honeywell Sensing and Productivity Solutions

CSNV500M-354M

CSNV500 SERIES HALL-BASED CLOSED

Honeywell Sensing and Productivity Solutions

3,706 -
Datasheet CSNV500 Module, Single Pass Through Box Active AC/DC Hall Effect, Closed Loop 500A 1 CAN Bus - - ±0.1% ±0.5% 7V ~ 18V - 250mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
RCM14-04_SYS Littelfuse/Western Automation

RCM14-04_SYS

RCM14-04 SYSTEM, CONSISTS OF 901

Littelfuse/Western Automation

547 -
Datasheet - Module, Single Pass Through Tray Active DC Current Sensor 56mA 1 - - DC ~ 60Hz - - 12V ~ 24V - 25mA -40°C ~ 85°C - - - Through Hole -
RC05-150-1000-S Pulse Electronics

RC05-150-1000-S

TRANSF CURR SENSE 150MV/KA 50HZ

Pulse Electronics

4,147 -
Datasheet RC05-SSSS-LLLL-O Module, Single Pass Through Tray Active AC/DC Rogowski Coil 8000A 1 - 0.15mV/A 50kHz - - - - - -20°C ~ 80°C - - - Free Hanging -
HAC 200-S LEM USA Inc.

HAC 200-S

SENSOR CURRENT HALL 200A AC/DC

LEM USA Inc.

2,614 -
Datasheet HAC Module Bulk Not For New Designs AC/DC Hall Effect, Open Loop 200A 1 Ratiometric, Voltage - DC ~ 50kHz ±1% ±1% ±15V 7µs 18mA -10°C ~ 80°C - - Bidirectional Chassis Mount -
Total 5184 Record«Prev1... 4243444546474849...260Next»
WINSUN SOURCING SUPPORT

Need Current Sensors Sourcing Support?

Send the manufacturer, part number, quantity and target delivery requirement. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and hard-to-find or obsolete components.

Global component sourcing support BOM, shortage and EOL support
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about selecting, comparing and sourcing Current Sensors components through Winsun (HK) Electronics.

What should I check when selecting Current Sensors components?

Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.

Can Winsun help source specific Current Sensors part numbers?

Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.

Do you support shortage, obsolete or hard-to-find Current Sensors parts?

Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.

How do I request a quote for Current Sensors components?

Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.