Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Current Sensors

Use the filters and product table below to compare Current Sensors components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
DS600UB-10V Danisense A/S

DS600UB-10V

CURRENT TRANSDUCER 600A

Danisense A/S

2,042 -
Datasheet DS Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 600A 1 Ratiometric, Voltage - DC ~ 300kHz ±0.004% - ±14.25V ~ 15.75V 1µs 104mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
DN1000ID Danisense A/S

DN1000ID

1000A CURRENT TRANSDUCER CURRENT

Danisense A/S

3,003 -
Datasheet DN Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 1000A 1 Ratiometric, Current - 31.25kHz - - 14.25V ~ 15.75V 1µs 1.1A -40°C ~ 85°C - - Bidirectional Chassis Mount -
DS1000UB-10V Danisense A/S

DS1000UB-10V

CURRENT TRANSDUCER 1000A

Danisense A/S

3,822 -
Datasheet DS Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 1000A 1 Ratiometric, Voltage - DC ~ 300kHz ±0.0035% - ±14.25V ~ 15.75V 1µs 104mA -40°C ~ 55°C - - Bidirectional Chassis Mount -
DM1200ID Danisense A/S

DM1200ID

CURRENT TRANSDUCER 1200A

Danisense A/S

1,929 -
Datasheet DM Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 1200A 1 Ratiometric, Current - DC ~ 300kHz ±0.0001% - ±14.25V ~ 15.75V 1µs 120mA -40°C ~ 65°C - - Bidirectional Chassis Mount -
DT50ID Danisense A/S

DT50ID

CURRENT TRANSDUCER 50A

Danisense A/S

1,627 -
Datasheet DT Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 50A 1 - - DC ~ 2MHz - - ±14.25V ~ ±15.75V 1µs 40mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
DT200ID Danisense A/S

DT200ID

CURRENT TRANSDUCER 200A

Danisense A/S

4,784 -
Datasheet DT Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 200A 1 - - DC ~ 2MHz - - ±14.25V ~ ±15.75V 1µs 40mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
DQ600ID Danisense A/S

DQ600ID

CURRENT TRANSDUCER 600A

Danisense A/S

4,495 -
Datasheet DQ Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 600A 1 - - DC ~ 500kHz ±0.0001% - ±14.25V ~ 15.75V 1µs 104mA -40°C ~ 85°C - - Bidirectional Chassis Mount -
SRCMH070IB+ Danisense A/S

SRCMH070IB+

TYPE B PROGRAMMABLE RESIDUAL CUR

Danisense A/S

4,419 -
Datasheet - Module, Single Pass Through Bulk Active AC/DC AC Single Phase/Three Phase 2A 1 4mA ~ 20mA, Relay - 100kHz - - 24V - - -20°C ~ 55°C - - Bidirectional Chassis Mount -
RCMH070IB+ Danisense A/S

RCMH070IB+

TYPE B RESIDUAL CURRENT MONITOR

Danisense A/S

1,402 -
Datasheet - Module, Single Pass Through Bulk Active AC/DC AC Single Phase/Three Phase 2A 1 4mA ~ 20mA, Relay - 100kHz - - 24V - - -20°C ~ 55°C - - Bidirectional Chassis Mount -
DM1200UB-10V Danisense A/S

DM1200UB-10V

CURRENT TRANSDUCER 1200A

Danisense A/S

4,496 -
Datasheet DM Module, Single Pass Through Bulk Active AC/DC Flux Gate, Closed Loop 1200A 1 Ratiometric, Voltage - DC ~ 300kHz ±0.0015% - ±14.25V ~ 15.75V 1µs 141mA -40°C ~ 65°C - - Bidirectional Chassis Mount -
Total 25 Record«Prev123Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Current Sensors?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about filtering, comparing and sourcing Current Sensors components.

How can I narrow the Current Sensors selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Current Sensors part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.