| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
L60S125.XFUSE CRTRDGE 125A 600VAC CYLINDR |
4,201 | - |
|
Datasheet | POWR-GARD® L60S | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 125A | 600 VAC | - | Fast Blow | Semiconductors | - | - | CE, CSA, UR | - | 200kA AC, 20kA DC | 1.311" Dia x 2.906" L (33.30mm x 73.80mm) | - | - |
|
L60S200.XFUSE CRTRDGE 200A 600VAC CYLINDR |
9,924 | - |
|
Datasheet | POWR-GARD® L60S | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 200A | 600 VAC | - | Fast Blow | Semiconductors | - | - | CE, CSA, UR | - | 200kA AC, 20kA DC | 1.311" Dia x 2.906" L (33.30mm x 73.80mm) | - | - |
|
LA070URD30LI0550FUSE SQUARE 550A 700VAC RECT |
9,480 | - |
|
Datasheet | POWR-GARD® LA | Rectangular, Blade | Box | Obsolete | Bolt Mount | Square | 550A | 700 VAC | - | Fast Blow | Electrical, Industrial | - | - | UR | - | 200kA | 5.850" L x 1.575" W x 1.575" H (148.60mm x 40.00mm x 40.00mm) | - | - |
|
LA070URD30LI0450FUSE SQUARE 450A 700VAC RECT |
7,486 | - |
|
Datasheet | POWR-GARD® LA | Rectangular, Blade | Box | Obsolete | Bolt Mount | Square | 450A | 700 VAC | - | Fast Blow | Electrical, Industrial | - | - | UR | - | 200kA | 5.850" L x 1.575" W x 1.575" H (148.60mm x 40.00mm x 40.00mm) | - | - |
|
LA070URD30LI0500FUSE SQUARE 500A 700VAC RECT |
6,989 | - |
|
Datasheet | POWR-GARD® LA | Rectangular, Blade | Box | Obsolete | Bolt Mount | Square | 500A | 700 VAC | - | Fast Blow | Electrical, Industrial | - | - | UR | - | 200kA | 5.850" L x 1.575" W x 1.575" H (148.60mm x 40.00mm x 40.00mm) | - | - |
|
0581750.XFUSE STRIP 750A 48VAC/VDC RECT |
5,187 | - |
|
Datasheet | POWR-GARD® HAZGARD | Rectangular, Blade | Bulk | Active | Bolt Mount | Fuse Strip | 750A | 48 VAC | 48 VDC | Fast Blow | Lift Trucks | - | - | UR | - | 2.5kA | 3.228" L x 1.195" W x 0.683" H (82.00mm x 30.35mm x 17.35mm) | - | - |
|
LA070URD30KI0550FUSE SQUARE 550A 700VAC RECT |
8,683 | - |
|
Datasheet | POWR-GARD® LA | Rectangular, Blade | Box | Obsolete | Bolt Mount | Square | 550A | 700 VAC | - | Fast Blow | Electrical, Industrial | - | - | UR | - | 200kA | 1.874" L x 1.575" W x 1.811" H (47.60mm x 40.00mm x 46.00mm) | - | - |
|
LA070URD30KI0450FUSE SQUARE 450A 700VAC RECT |
3,183 | - |
|
Datasheet | POWR-GARD® LA | Rectangular, Blade | Box | Obsolete | Bolt Mount | Square | 450A | 700 VAC | - | Fast Blow | Electrical, Industrial | - | - | UR | - | 200kA | 1.874" L x 1.575" W x 1.811" H (47.60mm x 40.00mm x 46.00mm) | - | - |
|
LA070URD30KI0500FUSE SQUARE 500A 700VAC RECT |
3,868 | - |
|
Datasheet | POWR-GARD® LA | Rectangular, Blade | Box | Obsolete | Bolt Mount | Square | 500A | 700 VAC | - | Fast Blow | Electrical, Industrial | - | - | UR | - | 200kA | 1.874" L x 1.575" W x 1.811" H (47.60mm x 40.00mm x 46.00mm) | - | - |
|
|
JLLS250.XFUSE CRTRDGE 250A 600VAC/300VDC |
7,789 | - |
|
Datasheet | POWR-GARD® JLLS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 250A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UL | - | 200kA | 1.594" Dia x 1.720" L (40.50mm x 43.70mm) | - | - |
Electrical, Specialty Fuses FAQ
Common questions about filtering, comparing and sourcing Electrical, Specialty Fuses components.
How can I narrow the Electrical, Specialty Fuses selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Electrical, Specialty Fuses part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.