Electrical, Specialty Fuses
Use the filters and product table below to compare Electrical, Specialty Fuses components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.
If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LFCL-UHJ-TFUSE CABLE LIMITER 250VAC BOLT |
6,804 | - |
|
Datasheet | POWR-GARD® LFCL | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cable Limiter | - | 250 VAC | - | Fast Blow | Cable Protection | - | - | - | - | 150kA | 1.500" Dia x 4.874" L (38.10mm x 123.80mm) | - | - |
|
0SPF008.TXS1000 VDC 8 AMP MIDGET FUSE SILVE |
3,473 | - |
|
Datasheet | POWR-GARD® SPF-S | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 8A | - | 1 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, IEC, gPV, UL | - | 20kA | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
1003R1C2.75SFUS 2.75KV MV R-RATED 3R SEALED |
5,309 | - |
|
Datasheet | POWR-GARD® | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 100A | 2.75 kVAC | - | Medium Blow | Electrical, Industrial | Indicating | - | - | - | 80kA | 3.000" Dia x 10.875" L (76.20mm x 276.23mm) | - | - |
|
1706R1C2.75SWFUS 2.75KV MV R-RATED 6R SEAL H |
6,126 | - |
|
Datasheet | POWR-GARD® | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 170A | 2.75 kVAC | - | Medium Blow | Electrical, Industrial | Indicating | - | - | - | 80kA | 3.000" Dia x 10.875" L (76.20mm x 276.23mm) | - | - |
|
0SPF006.TXS1000 VDC 6 AMP MIDGET FUSE SILVE |
4,705 | - |
|
Datasheet | POWR-GARD® SPF-S | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 6A | - | 1 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, IEC, gPV, UL | - | 20kA | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
0CNN150E.H80 VDC 150 AMP FORK LIFT FUSE |
3,147 | - |
|
Datasheet | POWR-GARD® CNN_E | Metal Strip | Box | Obsolete | Bolt Mount | Fuse Strip | 150A | 125 VAC | 80 VDC | Fast Blow | Lift Trucks | - | - | cURus | - | 2.7kA | - | - | - |
|
0SPF002.TXS1000 VDC 2 AMP MIDGET FUSE SILVE |
7,621 | - |
|
Datasheet | POWR-GARD® SPF-S | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 2A | - | 1 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, IEC, gPV, UL | - | 20kA | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
0SPF010.TXS1000VDC 10 AMP MIDGET FUSE SILVE |
2,663 | - |
|
Datasheet | POWR-GARD® SPF-S | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 10A | - | 1 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, CSA, IEC, gPV, UL | - | 20kA | 0.406" Dia x 1.500" L (10.31mm x 38.10mm) | - | - |
|
SPXV030.LXS1500VDC 30A PHOTOVOLTAIC FUSE SL |
4,454 | - |
|
Datasheet | POWR-GARD® SPXV-S | Cartridge, Non-Standard | Bulk | Obsolete | Requires Holder | Cartridge | 30A | - | 1.5 kVDC | Fast Blow | Solar (Photovoltaic) | - | - | CE, gPV, UL | - | 30kA | 0.540" Dia x 3.333" L (13.72mm x 84.65mm) | - | - |
|
LDFJ020.TFUS 600V H/S CLASS J 20A |
4,283 | - |
|
Datasheet | POWR-GARD® LDFJ | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 2A | 600 VAC | 450 VDC | Fast Blow | Electrical, Industrial | - | J | CE, CSA, UL | - | 200kA AC, 100kA DC | 0.811" Dia x 2.252" L (20.60mm x 57.20mm) | - | - |
Electrical, Specialty Fuses FAQ
Common questions about filtering, comparing and sourcing Electrical, Specialty Fuses components.
How can I narrow the Electrical, Specialty Fuses selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Electrical, Specialty Fuses part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.