| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A6D2R600V 2A RK1 TD FUSE |
3,142 | - |
|
Datasheet | A6D-R | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 2A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 0.811" Dia x 5.000" L (20.60mm x 127.00mm) | - | - |
|
A6T40FUSE,CLASS T,FAST ACTING,200KA A |
3,544 | - |
|
Datasheet | A6T | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 40A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | T | CSA, UL | - | 200kA AC, 100kA DC | 0.811" Dia x 1.547" L (20.60mm x 39.30mm) | - | - |
|
A6D45R600V 45A RK1 TD FUSE |
4,564 | - |
|
Datasheet | A6D-R | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 45A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 1.063" Dia x 5.472" L (27.00mm x 139.00mm) | - | - |
|
A6D50R600V 50A RK1 TD FUSE |
3,927 | - |
|
Datasheet | A6D-R | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 50A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 1.063" Dia x 5.472" L (27.00mm x 139.00mm) | - | - |
|
A4J15FUSE,CLASS J,HIGH SPEED,200KA AC |
3,293 | - |
|
Datasheet | A4J | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 15A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 0.827" Dia x 2.244" L (21.00mm x 57.00mm) | - | - |
|
A4J10600V 10A CLASS J FUSE |
3,519 | - |
|
Datasheet | A4J | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 10A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 0.827" Dia x 2.244" L (21.00mm x 57.00mm) | - | - |
|
A4J20600V 20A CLASS J FUSE |
3,949 | - |
|
Datasheet | A4J20 | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 20A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 0.827" Dia x 2.244" L (21.00mm x 57.00mm) | - | - |
|
OT200FUSE,CLASS K5,GENERAL PURPOSE,50 |
3,932 | - |
|
Datasheet | OT | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 200A | 250 VAC | 250 VDC | Fast Blow | Electrical, Industrial | - | K5 | CSA, UL | - | 50kA AC, 20kA DC | 1.575" Dia x 7.126" L (40.00mm x 181.00mm) | - | - |
|
TR100R250V 100A 5 7/8X1 1/16 RK |
4,270 | - |
|
Datasheet | TR-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 100A | 250 VAC | 250 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CSA, UL | - | 200kA AC, 20kA DC | 1.063" Dia x 5.866" L (27.00mm x 149.00mm) | - | - |
|
TR70R250V 70A 5 7/8X1 1/16 RK5 |
3,452 | - |
|
Datasheet | TR-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 70A | 250 VAC | 250 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CSA, UL | - | 200kA AC, 20kA DC | 1.063" Dia x 5.866" L (27.00mm x 149.00mm) | - | - |
Electrical, Specialty Fuses FAQ
Common questions about filtering, comparing and sourcing Electrical, Specialty Fuses components.
How can I narrow the Electrical, Specialty Fuses selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Electrical, Specialty Fuses part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.