Electrical, Specialty Fuses
Use the filters and product table below to compare Electrical, Specialty Fuses components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.
If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A4J300FUSE,CLASS J,HIGH SPEED,200KA AC |
4,982 | - |
|
Datasheet | A4J | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 300A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 2.126" Dia x 7.126" L (54.00mm x 181.00mm) | - | - |
|
A6D300R600V 300A RK1 TD FUSE |
1,526 | - |
|
Datasheet | A6D-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 300A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 2.598" Dia x 11.614" L (66.00mm x 295.00mm) | - | - |
|
CP500C3CABLE FUSE,TYPE3,500KCMIL,200KA |
3,891 | - |
|
Datasheet | CP/C3 | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cable Limiter | - | 600 VAC | - | Fast Blow | Cable Protection | - | - | - | - | 200kA | 1.890" Dia x 10.000" L (48.00mm x 254.00mm) | - | - |
|
A4J350FUSE,CLASS J,HIGH SPEED,200KA AC |
4,095 | - |
|
Datasheet | A4J | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 350A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 2.126" Dia x 7.126" L (54.00mm x 181.00mm) | - | - |
|
A4J250FUSE,CLASS J,HIGH SPEED,200KA AC |
4,531 | - |
|
Datasheet | A4J | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 250A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 2.126" Dia x 7.126" L (54.00mm x 181.00mm) | - | - |
|
TRS450R600V 450A 13 3/8X3 1/8 TD |
4,160 | - |
|
Datasheet | TRS-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 450A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK5 | CSA, UL | - | 200kA AC, 100kA DC | 3.150" Dia x 13.386" L (80.00mm x 340.00mm) | - | - |
|
TRS600RID600V 600A TD RK5 FUSE SMARTSPO |
3,221 | - |
|
Datasheet | TRS-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 600A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CSA, UL | - | 200kA AC, 100kA DC | 3.150" Dia x 13.386" L (80.00mm x 340.00mm) | - | - |
|
A6D600R600V 600A RK1 TD FUSE |
2,625 | - |
|
Datasheet | A6D-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 600A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 3.150" Dia x 13.386" L (80.00mm x 340.00mm) | - | - |
|
A4J600600V 600A CLASS J FUSE |
2,462 | - |
|
Datasheet | A4J | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 600A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 2.520" Dia x 7.992" L (64.00mm x 203.00mm) | - | - |
|
A6D500R600V 500A RK1 TD FUSE |
3,434 | - |
|
Datasheet | A6D-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 500A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 3.150" Dia x 13.386" L (80.00mm x 340.00mm) | - | - |
Electrical, Specialty Fuses FAQ
Common questions about filtering, comparing and sourcing Electrical, Specialty Fuses components.
How can I narrow the Electrical, Specialty Fuses selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Electrical, Specialty Fuses part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.