Gas Discharge Tube Arresters (GDT)
Browse available Gas Discharge Tube Arresters (GDT) part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
2063-70-ALFGDT 700V 60KA 2 POLE |
4,785 | - |
|
Datasheet | Cylinder No Lead | 2063 | Tray | Active | 700 V | 60000A (60kA) | ±20% | 2 | No | User Defined |
|
|
2063-35-ALFGDT 350V 60KA 2 POLE |
5,599 | - |
|
Datasheet | Cylinder No Lead | 2063 | Tray | Active | 350 V | 60000A (60kA) | ±20% | 2 | No | User Defined |
|
|
2063-47-ALFGDT 470V 60KA 2 POLE |
3,644 | - |
|
Datasheet | Cylinder No Lead | 2063 | Tray | Active | 470 V | 60000A (60kA) | ±20% | 2 | No | User Defined |
|
|
2063-60-ALFGDT 600V 60KA 2 POLE |
7,420 | - |
|
Datasheet | Cylinder No Lead | 2063 | Tray | Active | 600 V | 60000A (60kA) | ±20% | 2 | No | User Defined |
|
|
2063-80-ALFGDT 800V 60KA 2 POLE |
8,171 | - |
|
Datasheet | Cylinder No Lead | 2063 | Tray | Active | 800 V | 60000A (60kA) | ±20% | 2 | No | User Defined |
|
2033-140-G5-T1LFGDT 1400V 20KA 2 POLE |
8,595 | - |
|
Datasheet | Cylinder No Lead, 6 Terminal | 2033 | Tape & Reel (TR) | Active | 1400 V | 20000A (20kA) | ±30% | 2 | No | User Defined |
|
B88069X4390B152GDT 400V 20KA 2 POLE |
8,462 | - |
|
Datasheet | Cylinder No Lead | V1x | Bulk | Active | 400 V | 20000A (20kA) | - | 2 | No | User Defined |
|
2097-120-DLFGDT 1200V 20KA 2 POLE CHASSIS |
6,524 | - |
|
Datasheet | Axial Cylinder | 2097 | Tray | Active | 1200 V | 20000A (20kA) | ±20% | 2 | No | Chassis, Stud Mount |
|
2097-140-DLFGDT 1400V 20KA 2 POLE CHASSIS |
5,237 | - |
|
Datasheet | Axial Cylinder | 2097 | Tray | Active | 1400 V | 20000A (20kA) | ±20% | 2 | No | Chassis, Stud Mount |
|
2097-100-DLFGDT 1000V 20KA 2 POLE CHASSIS |
4,614 | - |
|
Datasheet | Axial Cylinder | 2097 | Tray | Active | 1000 V | 20000A (20kA) | ±20% | 2 | No | Chassis, Stud Mount |
|
2097-220-DLFGDT 2200V 20KA 2 POLE CHASSIS |
5,358 | - |
|
Datasheet | Axial Cylinder | 2097 | Tray | Active | 2200 V | 20000A (20kA) | ±20% | 2 | No | Chassis, Stud Mount |
|
GDT225E-50-A-BXGDT 500V 60KA 2 POLE |
2,949 | - |
|
Datasheet | Cylinder No Lead | GDT225E | Box | Active | 500 V | 60000A (60kA) | ±20% | 2 | No | User Defined |
|
A0264184GDT 700V 10KA 4 POLE TH |
4,670 | - |
|
Datasheet | Module, Plug-In | - | Bulk | Last Time Buy | 700 V | 10000A (10kA) | - | 4 | Yes | Through Hole |
|
A0260462GDT 700V 10KA 4 POLE TH |
4,506 | - |
|
Datasheet | Module, Plug-In | - | Bulk | Last Time Buy | 700 V | 10000A (10kA) | - | 4 | Yes | Through Hole |
|
B88069X1003T302GDT 1400V 20KA 5 POLE |
6,521 | - |
|
Datasheet | Cylinder No Lead, 6 Terminal | LN8A | Tape & Reel (TR) | Active | 1400 V | 20000A (20kA) | ±30% | 5 | No | User Defined |
|
9400110000GDT 150V 2.5KA DIN RAIL |
9,085 | - |
|
Datasheet | Module | - | Bulk | Obsolete | 150 V | 2500A (2.5kA) | ±15% | - | - | DIN Rail |
|
GDT225E-80-T1-BXGDT 800V 60KA 2 POLE SMD |
7,862 | - |
|
Datasheet | 2-SMD | GDT225E | Box | Active | 800 V | 60000A (60kA) | ±20% | 2 | No | Surface Mount |
|
GDT225E-60-T1-BXGDT 600V 60KA 2 POLE SMD |
2,059 | - |
|
Datasheet | 2-SMD | GDT225E | Box | Active | 600 V | 60000A (60kA) | ±20% | 2 | No | Surface Mount |
|
GDT225E-60-T2-BXGDT 600V 60KA 2 POLE TH |
8,706 | - |
|
Datasheet | Axial Cylinder, Radial Bend | GDT225E | Box | Active | 600 V | 60000A (60kA) | ±20% | 2 | No | Through Hole |
|
GDT225E-50-T1-BXGDT 500V 60KA 2 POLE SMD |
3,354 | - |
|
Datasheet | 2-SMD | GDT225E | Box | Active | 500 V | 60000A (60kA) | ±20% | 2 | No | Surface Mount |
Gas Discharge Tube Arresters (GDT) FAQ
Common questions about selecting, comparing and sourcing Gas Discharge Tube Arresters (GDT) components through Winsun (HK) Electronics.
What should I check when selecting Gas Discharge Tube Arresters (GDT) components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Gas Discharge Tube Arresters (GDT) part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Gas Discharge Tube Arresters (GDT) parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Gas Discharge Tube Arresters (GDT) components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.