Gas Sensors
Browse available Gas Sensors part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature | Voltage - Supply | Current - Supply |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CMT200SENSOR CARBON MONOXIDE TRANS |
4,877 | - |
|
Datasheet | * | Retail Package | Active | - | - | - | - | - | - | - |
|
PR55-59_THPC_9HPSENSOR AIR QUALITY |
3,394 | - |
|
Datasheet | - | Box | Active | Air Quality | - | 2% | - | -25°C ~ 85°C | - | - |
|
PD2BTVOC PID sensor 10.6eV 200ppm |
3,678 | - |
|
Datasheet | - | Retail Package | Active | Volatile Organic Compound (VOC) | - | 3% | Analog | -40°C ~ 55°C | 3.2V ~ 5.5V | 30mA |
|
PD2CTVOC PID sensor 10.6eV 20ppm |
2,761 | - |
|
Datasheet | - | Retail Package | Active | - | - | - | - | - | - | - |
|
SEN50-SDN-TSENSOR PARTICULATE MATTER I2C |
1,781 | - |
|
Datasheet | SEN5x | Tray | Active | Particulate Matter | - | ±4.5% RH | I2C | -10°C ~ 50°C | 4.5V ~ 5.5V | - |
|
SCD40-D-R1SENSOR AIR QUALITY I2C OUTPUT |
3,618 | - |
|
Datasheet | - | Tape & Reel (TR) | Active | Air Quality | - | ±5% | I2C | -10°C ~ 60°C | 2.4V ~ 5.5V | - |
|
STC31-C-R3SENSOR CARBON DIOXIDE I2C OUTPUT |
3,036 | - |
|
Datasheet | CMOSens® | Tape & Reel (TR) | Active | Carbon Dioxide (CO2) | 200 mbar ~ 2000 mbar | ±0.5% | I2C | -40°C ~ 105°C | 2.7V ~ 5.5V | 5mA |
|
SFA30-D-TSENSOR FORMALDEHYDE I2C OUTPUT |
4,838 | - |
|
Datasheet | - | Tray | Active | Formaldehyde (HCHO) | - | ±20% | I2C, UART | 0°C ~ 40°C | 3.15V ~ 5.5V | 1mA |
|
INIR2-ME100%SENSOR METHANE ANALOG OUTPUT |
2,081 | - |
|
Datasheet | INIR | Bulk | Active | Methane | - | - | Analog | -40°C ~ 75°C | 3.2V ~ 5.25V | 32mA |
|
SPRINTIR-R-20SENSOR CARBON DIOXIDE UART OUT |
2,890 | - |
|
Datasheet | SprintIR®-R | Box | Active | Carbon Dioxide (CO2) | - | ±5% | UART | 0°C ~ 50°C | 3.25V ~ 5.5V | 40mA |
|
SNS-MQ2SENSOR HYDROGEN/METHANE ANALOG |
2,267 | - |
|
Datasheet | - | Bulk | Active | Hydrogen, Methane, Propane | - | - | Analog, Digital | - | 5V | 40mA |
|
5593SENSOR VOC I2C OUTPUT |
3,279 | - |
|
Datasheet | - | Bulk | Active | Volatile Organic Compound (VOC) | 0 mbar ~ 2.5 bar | ±25% | I2C | 0°C ~ 50°C | 3.3V ~ 5.5V | 28mA |
|
004-1-0101SENSEAIR S88 LP |
3,210 | - |
|
Datasheet | - | Box | Active | Carbon Dioxide (CO2) | 0.01 mbar ~ 0.25 mbar | ±3% | UART | 0°C ~ 50°C | 4.5V ~ 5.25V | - |
|
USEQGSEAC82180SENSOR CARBON DIOXIDE I2C OUTPUT |
1,105 | - |
|
Datasheet | QGS | Tape & Reel (TR) | Active | Carbon Dioxide (CO2) | - | - | I2C | -40°C ~ 85°C | 1.75V ~ 3.6V | 23µA |
|
970-650DGS2-C2H4 DIGITAL GAS SENSOR |
4,114 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Ethylene (C2H4) | 0 mbar ~ 1 bar | ±15% | UART | -40°C ~ 50°C | 2.6V ~ 3.6V | 10mA |
|
972-400SENSOR OZONE UART OUTPUT |
3,622 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Ozone (O3) | 0 mbar ~ 500 mbar | ±15% | UART | -20°C ~ 40°C | 2.6V ~ 3.6V | 10mA |
|
INIR2-PR2,1%SENSOR PROPANE ANALOG OUTPUT |
2,381 | - |
|
Datasheet | INIR | Bulk | Active | Propane (C3H8) | - | - | Analog | -40°C ~ 75°C | 3.2V ~ 5.25V | 32mA |
|
T3032-2-5K-24-PSENSOR CARB DIOXIDE 4MA-20MA OUT |
4,768 | - |
|
Datasheet | T3000 | Bulk | Active | Carbon Dioxide (CO2) | - | ±5% | 4mA ~ 20mA | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | - |
|
OXY-LC-V100-455SENSOR OXYGEN 0-10V OUTPUT |
3,973 | - |
|
Datasheet | - | Bulk | Active | Oxygen (O2) | 260 mbar ~ 1.26 bar | ±0.5% | 0 V ~ 10 V | -30°C ~ 70°C | 20V ~ 28V | 600mA |
|
OXY-LC-A25-455SENSOR OXYGEN 4MA-20MA OUTPUT |
1,277 | - |
|
Datasheet | - | Bulk | Active | Oxygen (O2) | 260 mbar ~ 1.26 bar | ±0.5% | 4mA ~ 20mA | -30°C ~ 70°C | 20V ~ 28V | 600mA |
Gas Sensors FAQ
Common questions about selecting, comparing and sourcing Gas Sensors components through Winsun (HK) Electronics.
What should I check when selecting Gas Sensors components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Gas Sensors part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Gas Sensors parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Gas Sensors components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.