Distance Measuring
Browse available Distance Measuring part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Sensing Distance | Output Type | Voltage - Supply | Operating Temperature | Current - Supply | Voltage - Output Difference (Typ) @ Distance | Voltage - Output (Typ) @ Distance |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LE550UC1QSENSOR OPTICAL 5-200CM ANALOG |
4,734 | - |
|
Datasheet | LE | Box | Active | 3.94" ~ 39.37" (10 ~ 100cm) | Analog | 12V ~ 30V | 70 mA | - | - | -20°C ~ 55°C |
|
SNS-HCSR04SENSOR OPTICAL 20-100CM TTL |
4,740 | - |
|
Datasheet | - | Bulk | Active | 0.59" ~ 177.17" (2 ~ 450cm) | TTL | 5V | - | - | - | - |
|
164SENSOR OPTICAL ANALOG |
3,828 | - |
|
Datasheet | - | Bulk | Active | 3.94" ~ 31.50" (10 ~ 80cm) | Analog | 4.5V ~ 5.5V | 40 mA | 2.6V @ 10 ~ 80cm | 400mV @ 80cm | -10°C ~ 60°C |
|
SEN0588SENSOR OPTICAL 3-4CM UART |
2,379 | - |
|
Datasheet | - | Box | Active | 1.969" ~ 590.551" (50mm ~ 15m) | UART | 4.8V ~ 5.2V | 100 mA | - | - | -10°C ~ 50°C |
|
|
SEN0309SENSOR OPTICAL 20-1000CM UART |
4,691 | - |
|
Datasheet | - | Bulk | Active | 3.94" ~ 472.44" (10 ~ 1200cm) | UART | 4.5V ~ 5.5V | 500 mA | - | - | -20°C ~ 60°C |
|
SEN0491SENSOR OPTICAL 20-10000CM UART |
4,555 | - |
|
Datasheet | - | Bulk | Active | 1.57" ~ 157.48" (4cm ~ 400cm) | UART | 6V ~ 36V | 38 mA | - | - | -20°C ~ 70°C |
|
SEN0492SENSOR OPTICAL 20-10000CM RS-485 |
2,481 | - |
|
Datasheet | - | Bulk | Active | 1.57" ~ 157.48" (4cm ~ 400cm) | RS-485 | 5V ~ 36V | 38 mA | - | - | -20°C ~ 70°C |
|
SEN0366SENSOR OPTICAL - UART |
3,320 | - |
|
Datasheet | - | Bulk | Active | 1.97" ~ 3149.60" (5 ~ 8000cm) | UART | 3.3V ~ 5V | - | - | - | -10°C ~ 60°C |
|
SEN0238SENSOR OPTICAL 4-30CM |
2,085 | - |
|
Datasheet | - | Bulk | Active | 1.97" ~ 1574.80" (5 ~ 4000cm) | - | 5V ~ 12V | 200 mA | - | - | -20°C ~ 60°C |
|
PBBSENSOR OPTICAL 10-400CM |
1,529 | - |
|
Datasheet | MULTI-BEAM® | Box | Active | - | - | 210V ~ 250V | - | - | - | - |
|
P12-C1SENSOR OPTICAL 5-800CM |
4,336 | - |
|
Datasheet | - | Box | Active | 0.12" (0.3cm) | - | - | - | - | - | -40°C ~ 70°C |
|
PLI-A10SENSOR OPTICAL 5.08-121.92CM |
2,426 | - |
|
Datasheet | - | Box | Active | 0.31" ~ 1.26" (0.8 ~ 3.2cm) | - | - | - | - | - | -40°C ~ 70°C |
|
PBAT43TMB5MTASENSOR OPTICAL 50-400M |
2,124 | - |
|
Datasheet | PBAT4 | Box | Active | - | - | - | - | - | - | 70°C |
|
SEN-18580SENSOR OPT 10-1200CM TTL |
2,341 | - |
|
Datasheet | - | Bulk | Active | 1.97" ~ 78.74" (5 ~ 200cm), 7.87" ~ 314.96" (20 ~ 800cm) | TTL, UART | 5V | 500 mA | - | - | -10°C ~ 50°C |
|
DFR0445SENSOR OPTICAL 30-1200CM |
4,685 | - |
|
Datasheet | RPLIDAR A2 | Bulk | Active | 5.91" ~ 314.96" (15 ~ 800cm) | - | - | - | - | - | - |
|
SF23/BSENSOR OPTICAL SERIAL |
4,332 | - |
|
Datasheet | SF23 | Box | Active | 7.87" ~ 1968.50" (20 ~ 5000cm) | Serial | 3.2V ~ 5.5V | 5 mA | - | - | -10°C ~ 50°C |
|
SEN0329SENSOR OPTICAL 20MM UART |
1,641 | - |
|
Datasheet | - | Bulk | Active | 3.94" ~ 7086.61" (10 ~ 18000cm) | UART | 4.5V ~ 5.5V | 180 mA | - | - | -25°C ~ 60°C |
|
LE550KC1QSENSOR OPTICAL 10-18000CM |
2,208 | - |
|
Datasheet | LE | Box | Active | 3.94" ~ 39.37" (10 ~ 100cm) | - | 12V ~ 30V | 70 mA | - | - | -20°C ~ 55°C |
|
LE550ISENSOR OPTICAL 30-500CM ANALOG |
1,116 | - |
|
Datasheet | LE | Box | Active | 3.94" ~ 39.37" (10 ~ 100cm) | Analog | 12V ~ 30V | 70 mA | - | - | -20°C ~ 55°C |
|
7006815SENSOR OPT 0.46-50M ANALOG |
1,836 | - |
|
Datasheet | TruSense™ S330 | Bulk | Active | 1.51' ~ 164.04' (0.46 ~ 50m) | Analog, RS-232 | 12V ~ 24V | - | - | - | -28°C ~ 60°C |
Distance Measuring FAQ
Common questions about selecting, comparing and sourcing Distance Measuring components through Winsun (HK) Electronics.
What should I check when selecting Distance Measuring components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Distance Measuring part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Distance Measuring parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Distance Measuring components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.