Energy Metering
Browse available Energy Metering part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Input Impedance | Measurement Error | Voltage - I/O High | Voltage - I/O Low | Current - Supply | Voltage - Supply | Meter Type | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
MCP39F511T-E/MQIC POWER MONITOR 1PH 28QFN |
4,372 | - |
|
Datasheet | - | 28-VFQFN Exposed Pad | Tape & Reel (TR) | Active | - | 0.1% | 3V | 0.4V | 7mA | 2.7 V ~ 3.6 V | Single Phase | -40°C ~ 125°C | - | - | Surface Mount | 28-QFN (5x5) |
|
MCP39F521T-E/MQIC PWR MONITOR I2C 1PH 28VQFN |
3,970 | - |
|
Datasheet | - | 28-VFQFN Exposed Pad | Tape & Reel (TR) | Active | - | 0.1% | 3V | 0.4V | 13mA | 2.7 V ~ 3.6 V | Single Phase | -40°C ~ 125°C | - | - | Surface Mount | 28-QFN (5x5) |
|
MCP39F511NT-E/MQIC PWR MONITOR 2CH 1PH 28QFN |
1,735 | - |
|
Datasheet | - | 28-VFQFN Exposed Pad | Tape & Reel (TR) | Active | - | 0.1% | 3V | 0.4V | 7mA | 2.7 V ~ 3.6 V | Single Phase | -40°C ~ 125°C | - | - | Surface Mount | 28-QFN (5x5) |
|
71M6541FT-IGT/FIC ENERGY METER 64-LQFP |
3,767 | - |
|
Datasheet | Single Converter Technology® | 64-LQFP | Tray | Discontinued at Digi-Key | - | 0.1% | 2V | 0.8V | - | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
71M6511H-IGTR/FIC ENERGY METER RESIDENT 64-LQFP |
4,628 | - |
|
Datasheet | Single Converter Technology® | 64-LQFP | Tape & Reel (TR) | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.1% | 2V | 0.8V | - | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
MAX71020AEUI+IC ENERGY METER 1PH 28TSSOP |
2,840 | - |
|
Datasheet | - | 28-TSSOP (0.173", 4.40mm Width) | Tube | Discontinued at Digi-Key | 50kOhm ~ 100kOhm | 0.5% | -1.1V, 2V | 0.8V, 0.96V | 3mA | 2.8 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-TSSOP |
|
MAX71020AETI+IC AFE ELECTRIC METER QFN |
3,315 | - |
|
Datasheet | - | 28-WFQFN Exposed Pad | Tube | Discontinued at Digi-Key | 50kOhm ~ 100kOhm | 0.5% | -1.1V, 2V | 0.8V, 0.96V | 3mA | 2.8 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-TQFN (4x4) |
|
78M6612-IMR/FIC POWER MEASUREMENT AC 68-QFN |
3,056 | - |
|
Datasheet | Single Converter Technology® | 68-VFQFN Exposed Pad | Tape & Reel (TR) | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.5% | 2V | 0.8V | - | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 68-SQFN (8x8) |
|
78M6613-IM/FIC AC PWR MON APPLIANCES 32-QFN |
4,336 | - |
|
Datasheet | Teridian™ | 32-VFQFN Exposed Pad | Tube | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.5% | 2V | 0.8V | 9.1mA | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 32-QFN-EP (5x5) |
|
CS5460A-BSZRIC ENERGY METERING 1PHASE 24SSOP |
3,512 | - |
|
Datasheet | - | 24-SSOP (0.209", 5.30mm Width) | Tape & Reel (TR) | Obsolete | 30kOhm | 0.1% | 0.8V | 0.2V | 2.9mA | 4.75 V ~ 5.25 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 24-SSOP |
|
78M6611-IVT/FIC POWER MEASUREMENT AC 24-TSSOP |
3,551 | - |
|
Datasheet | - | - | Tube | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - |
|
78M6612-IGTR/FIC POWER MEASUREMENT AC 64-LQFP |
2,220 | - |
|
Datasheet | Single Converter Technology® | 64-LQFP | Tape & Reel (TR) | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.5% | 2V | 0.8V | - | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
78M6612-MR/F/P2IC PWR MEASUREMENT AC 68SQFN |
3,447 | - |
|
Datasheet | Single Converter Technology® | 68-VFQFN Exposed Pad | Tape & Reel (TR) | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.5% | 2V | 0.8V | - | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 68-SQFN (8x8) |
|
78M6613-IMR/F/PSPIC PWR MEASUREMENT 1PH AC 32SQFN |
1,578 | - |
|
Datasheet | Teridian™ | 32-VFQFN Exposed Pad | Tape & Reel (TR) | Obsolete | 40kOhm ~ 90kOhm | 0.5% | 2V | 0.8V | 9.1mA | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 32-SQFN (5x5) |
|
|
CS5464-ISZRIC ENERGY METERING 1PHASE 28SSOP |
4,547 | - |
|
Datasheet | - | 28-SSOP (0.209", 5.30mm Width) | Tape & Reel (TR) | Active | 30kOhm | 0.1% | 0.8V | 0.2V | 3.5mA | 4.75 V ~ 5.25 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 28-SSOP |
|
78M6613-IM/F/PP1IC PWR MEASUREMENT AC 32SQFN |
1,000 | - |
|
Datasheet | Teridian™ | 32-VFQFN Exposed Pad | Tube | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.5% | 2V | 0.8V | 9.1mA | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 32-QFN-EP (5x5) |
|
78M6613-IM/F/PW4IC PWR MEASUREMENT 1PH AC 32SQFN |
2,363 | - |
|
Datasheet | Teridian™ | 32-VFQFN Exposed Pad | Tube | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.5% | 2V | 0.8V | 9.1mA | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 32-QFN-EP (5x5) |
|
78M6613-IM/F/PW2IC PWR MEASUREMENT AC 32SQFN |
3,812 | - |
|
Datasheet | Teridian™ | 32-VFQFN Exposed Pad | Tube | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.5% | 2V | 0.8V | 9.1mA | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 32-QFN (5x5) |
|
71M6511-IGT/FIC ENERGY METER RESIDENT 64-LQFP |
2,975 | - |
|
Datasheet | Single Converter Technology® | 64-LQFP | Tray | Discontinued at Digi-Key | 40kOhm ~ 90kOhm | 0.1% | 2V | 0.8V | - | 3 V ~ 3.6 V | Single Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
|
71M6545T-IGTR/FIC ENERGY METER 64-LQFP |
2,436 | - |
|
Datasheet | Single Converter Technology® | 64-LQFP | Tape & Reel (TR) | Obsolete | - | 0.1% | 2V | 0.8V | - | 3 V ~ 3.6 V | 3 Phase | -40°C ~ 85°C | - | - | Surface Mount | 64-LQFP (10x10) |
Energy Metering FAQ
Common questions about selecting, comparing and sourcing Energy Metering components through Winsun (HK) Electronics.
What should I check when selecting Energy Metering components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Energy Metering part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Energy Metering parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Energy Metering components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.