| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Coil Voltage | Contact Form | Contact Rating (Current) | Switching Voltage | Load - Max Switching | Coil Current | Coil Type | Features | Termination Style | Seal Rating | Coil Insulation | Must Operate Voltage | Must Release Voltage | Operate Time | Release Time | Operating Temperature | Contact Material | Relay Type | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
3-1393807-6RELAY GEN PURP |
3,767 | - |
|
Datasheet | V23154, AXICOM | Bulk | Active | Socketable | - | DPDT (2 Form C) | 5 A | 250VAC, 250VDC - Max | - | - | Non Latching | - | Plug In | - | - | - | - | 7.5 ms | 3 ms | -40°C ~ 70°C | Silver (Ag), Gold (Au) | General Purpose | - | - |
|
5-1393807-3RELAY GEN PURP |
3,422 | - |
|
Datasheet | V23154, AXICOM | Bulk | Active | Socketable | - | DPDT (2 Form C) | 5 A | 250VAC, 250VDC - Max | - | - | Non Latching | - | Plug In | - | - | - | - | 7.5 ms | 3 ms | -40°C ~ 70°C | Silver (Ag), Gold (Au) | General Purpose | - | - |
|
3-1393810-2RELAY GEN PURPOSE DPST 5A 24V |
1,940 | - |
|
Datasheet | V23154, AXICOM | Bulk | Active | Through Hole | 24VDC | DPST-NO (2 Form A) | 5 A | 125VAC, 150VDC - Max | 625VA, 750W | 16.7 mA | Non Latching | - | PC Pin | - | - | 11 VDC | - | 7.5 ms | 3 ms | -40°C ~ 70°C | Silver (Ag) | General Purpose | - | - |
|
3-1393810-7RELAY GEN PURPOSE DPST 5A 32V |
1,358 | - |
|
Datasheet | V23154, AXICOM | Bulk | Obsolete | Through Hole | 32VDC | DPST-NO/NC (1 Form A, 1 Form B) | 5 A | 125VAC, 150VDC - Max | 625VA, 750W | 16.7 mA | Non Latching | - | PC Pin | - | - | 16 VDC | - | 7.5 ms | 3 ms | -40°C ~ 70°C | Silver (Ag) | General Purpose | - | - |
|
6-1393807-2RELAY GEN PURP |
2,483 | - |
|
Datasheet | V23154, AXICOM | Bulk | Active | Socketable | - | DPDT (2 Form C) | 5 A | 250VAC, 250VDC - Max | - | - | Non Latching | - | Plug In | - | - | - | - | 7.5 ms | 3 ms | -40°C ~ 70°C | Silver (Ag), Gold (Au) | General Purpose | - | - |
|
|
2-1393809-4RELAY GEN PURPOSE DPDT 5A 32V |
2,768 | - |
|
Datasheet | V23154, AXICOM | Bulk | Obsolete | Socketable | 32VDC | DPDT (2 Form C) | 5 A | 125VAC, 150VDC - Max | 625VA, 750W | 16.7 mA | Non Latching | - | Plug In | - | - | 22.6 VDC | - | 7.5 ms | 3 ms | -40°C ~ 70°C | Silver (Ag) | General Purpose | - | - |
|
2-1393807-8RELAY GEN PURPOSE DPDT 5A |
2,627 | - |
|
Datasheet | V23154, AXICOM | Bulk | Obsolete | Socketable | - | DPDT (2 Form C) | 5 A | 125VAC, 150VDC - Max | 625VA, 750W | - | Non Latching | - | Plug In | - | - | - | - | 7.5 ms | 3 ms | -40°C ~ 70°C | Silver (Ag) | General Purpose | - | - |
|
6-1393810-1RELAY GEN PURPOSE DPDT 5A 12V |
2,932 | - |
|
Datasheet | V23154, AXICOM | Bulk | Active | Through Hole | 12VDC | DPDT (2 Form C) | 5 A | 125VAC, 150VDC - Max | 625VA, 750W | 16.7 mA | Non Latching | - | PC Pin | - | - | 5.3 VDC | - | 7.5 ms | 3 ms | -40°C ~ 70°C | Silver (Ag) | General Purpose | - | - |
|
PRD-60029POWER RELAY ASSEMBLY |
2,800 | - |
|
Datasheet | PRD | Bulk | Obsolete | Chassis Mount | - | - | 50 A | 600VAC, 125VDC - Nom | - | - | Non Latching | - | - | - | Class B | - | - | 40 ms | 20 ms | - | - | General Purpose | - | - |
|
PRDA-11AJA-120RELAY GEN PURPOSE DPDT 20A 120V |
3,621 | - |
|
Datasheet | PRDA | Bulk | Obsolete | Chassis Mount | 120VAC | DPDT (2 Form C) | 20 A | 600VAC, 125VDC - Nom | - | 85 mA | Non Latching | - | Screw Terminal | - | Class B | 102 VAC | 12 VAC | 40 ms | 20 ms | -55°C ~ 45°C | Silver Cadmium Oxide (AgCdO) | General Purpose | - | - |
Power Relays, Over 2 Amps FAQ
Common questions about filtering, comparing and sourcing Power Relays, Over 2 Amps components.
How can I narrow the Power Relays, Over 2 Amps selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Power Relays, Over 2 Amps part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.