Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Power Relays, Over 2 Amps

Use the filters and product table below to compare Power Relays, Over 2 Amps components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Load - Max Switching Coil Current Coil Type Features Termination Style Seal Rating Coil Insulation Must Operate Voltage Must Release Voltage Operate Time Release Time Operating Temperature Contact Material Relay Type Grade Qualification
8-1415062-1 TE Connectivity Potter & Brumfield Relays

8-1415062-1

RELAY GEN PURPOSE SPST 6A 5V

TE Connectivity Potter & Brumfield Relays

3,189 -
Datasheet RE, SCHRACK Bulk Obsolete Through Hole 5VDC SPST-NO (1 Form A) 6 A 400VAC - Max 2400VA 40 mA Non Latching - PC Pin Sealed - Fully Class F 3.5 VDC 0.5 VDC 10 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
9-1415062-1 TE Connectivity Potter & Brumfield Relays

9-1415062-1

RELAY GEN PURPOSE SPST 6A 12V

TE Connectivity Potter & Brumfield Relays

4,845 -
Datasheet RE, SCHRACK Bulk Obsolete Through Hole 12VDC SPST-NO (1 Form A) 6 A 400VAC - Max 2400VA 16.7 mA Non Latching - PC Pin Sealed - Fully Class F 8.4 VDC 1.2 VDC 10 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
6-1393224-5 TE Connectivity Potter & Brumfield Relays

6-1393224-5

RELAY GEN PURPOSE SPST 8A 48V

TE Connectivity Potter & Brumfield Relays

1,658 -
Datasheet RY, SCHRACK Bulk Obsolete Through Hole 48VDC SPST-NO (1 Form A) 8 A 400VAC - Max 3200VA 5.1 mA Non Latching - PC Pin Sealed - Flux Protection - 33.6 VDC 4.8 VDC 9 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
7-1393224-0 TE Connectivity Potter & Brumfield Relays

7-1393224-0

RELAY GEN PURPOSE SPST 8A 15V

TE Connectivity Potter & Brumfield Relays

4,756 -
Datasheet RY, SCHRACK Bulk Obsolete Through Hole 15VDC SPST-NO (1 Form A) 8 A 400VAC - Max 3200VA - Non Latching - PC Pin Sealed - Flux Protection - 10.5 VDC 1.5 VDC 9 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
7-1393224-3 TE Connectivity Potter & Brumfield Relays

7-1393224-3

RELAY GEN PURPOSE SPST 8A 32V

TE Connectivity Potter & Brumfield Relays

1,807 -
Datasheet RY, SCHRACK Bulk Obsolete Through Hole 32VDC SPST-NO (1 Form A) 8 A 400VAC - Max 3200VA - Non Latching - PC Pin Sealed - Flux Protection - 22.4 VDC 3.2 VDC 9 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
3-1415391-1 TE Connectivity Potter & Brumfield Relays

3-1415391-1

RELAY GEN PURPOSE SPDT 8A 8V

TE Connectivity Potter & Brumfield Relays

1,767 -
Datasheet RY, SCHRACK Bulk Obsolete Through Hole 8VDC SPDT (1 Form C) 8 A 400VAC - Max 3200VA - Non Latching - PC Pin Sealed - Fully - 5.6 VDC 0.8 VDC 9 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
1-1393225-3 TE Connectivity Potter & Brumfield Relays

1-1393225-3

RELAY GEN PURPOSE SPDT 8A 21V

TE Connectivity Potter & Brumfield Relays

2,415 -
Datasheet RY, SCHRACK Bulk Obsolete Through Hole 21VDC SPDT (1 Form C) 8 A 400VAC - Max 3200VA - Non Latching - PC Pin Sealed - Fully - 14.7 VDC 2.1 VDC 9 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
4-1393224-0 TE Connectivity Potter & Brumfield Relays

4-1393224-0

RELAY GEN PURPOSE SPDT 8A 36V

TE Connectivity Potter & Brumfield Relays

1,773 -
Datasheet RY, SCHRACK Bulk Obsolete Through Hole 36VDC SPDT (1 Form C) 8 A 400VAC - Max 3200VA - Non Latching - PC Pin Sealed - Flux Protection - 25.2 VDC 3.6 VDC 9 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
9-1393224-5 TE Connectivity Potter & Brumfield Relays

9-1393224-5

RELAY GEN PURPOSE SPST 8A 18V

TE Connectivity Potter & Brumfield Relays

4,620 -
Datasheet RY, SCHRACK Bulk Obsolete Through Hole 18VDC SPST-NC (1 Form B) 8 A 400VAC - Max 3200VA - Non Latching - PC Pin Sealed - Flux Protection - 12.6 VDC 1.8 VDC 9 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
4-1393225-0 TE Connectivity Potter & Brumfield Relays

4-1393225-0

RELAY GEN PURPOSE SPDT 8A 48V

TE Connectivity Potter & Brumfield Relays

4,784 -
Datasheet RY, SCHRACK Bulk Obsolete Through Hole 48VDC SPDT (1 Form C) 8 A 400VAC - Max 3200VA 5.1 mA Non Latching - PC Pin Sealed - Flux Protection - 33.6 VDC 4.8 VDC 9 ms 5 ms -40°C ~ 70°C Silver Cadmium Oxide (AgCdO) General Purpose - -
Total 4405 Record«Prev1... 430431432433434435436437...441Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Power Relays, Over 2 Amps?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Power Relays, Over 2 Amps FAQ

Common questions about filtering, comparing and sourcing Power Relays, Over 2 Amps components.

How can I narrow the Power Relays, Over 2 Amps selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Power Relays, Over 2 Amps part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.