Power Relays, Over 2 Amps
Use the filters and product table below to compare Power Relays, Over 2 Amps components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.
If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Coil Voltage | Contact Form | Contact Rating (Current) | Switching Voltage | Load - Max Switching | Coil Current | Coil Type | Features | Termination Style | Seal Rating | Coil Insulation | Must Operate Voltage | Must Release Voltage | Operate Time | Release Time | Operating Temperature | Contact Material | Relay Type | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
1456980000RSMS-16 48V+ 1CO S |
2,318 | - |
|
Datasheet | - | Box | Active | Chassis Mount | 48VDC | SPDT (1 Form C) x 16 | 4.5 A | 250VAC - Max | 1125VA | 4.5 mA | Non Latching | Lighted Indicator | Screw Terminal | - | - | - | - | - | - | -25°C ~ 50°C | Silver Nickel (AgNi) | General Purpose | - | - |
|
1113661001RELAY GEN PURPOSE SPDT 6A 24V |
1,473 | - |
|
Datasheet | RSM | Bulk | Active | DIN Rail | 24VDC | SPDT (1 Form C) x 8 | 6 A | 250VAC - Max | 1500VA | 23 mA | Non Latching | Lighted Indicator, Socket Included | Screw Terminal | - | - | - | - | 8 ms | 7 ms | -25°C ~ 50°C | Silver Nickel (AgNi) | General Purpose | - | - |
|
2550210000RSMI-16 C 1CO S |
1,326 | - |
|
Datasheet | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
9444610000RELAY GEN PURPOSE SPDT 5A 24V |
1,510 | - |
|
Datasheet | RSM | Bulk | Active | DIN Rail | 24VDC | SPDT (1 Form C) | 5 A | 250VAC - Max | 1500VA | 22 mA | Non Latching | Lighted Indicator, Socket Included | Screw Terminal | - | - | - | - | - | - | -25°C ~ 40°C | Silver Nickel (AgNi) | General Purpose | - | - |
|
1449210000RSM-16 24V+ 2CO S |
1,740 | - |
|
Datasheet | RSM | Box | Active | DIN Rail | 24VDC | DPDT (2 Form C) x 16 | 5 A | 250VAC - Max | 1250VA | 16.7 mA | Non Latching | Lighted Indicator | Screw Terminal | - | - | - | - | - | - | -25°C ~ 50°C | Silver Nickel (AgNi) | General Purpose | - | - |
|
1449220000RSM-16 24V- 2CO S |
4,473 | - |
|
Datasheet | RSM | Box | Active | DIN Rail | 24VDC | DPDT (2 Form C) x 16 | 5 A | 250VAC - Max | 1250VA | 16.7 mA | Non Latching | Lighted Indicator | Screw Terminal | - | - | - | - | - | - | -25°C ~ 50°C | Silver Nickel (AgNi) | General Purpose | - | - |
|
1449170000RSM-16 12V+ 2CO S |
4,146 | - |
|
Datasheet | RSM | Box | Active | DIN Rail | 12VDC | DPDT (2 Form C) x 16 | 5 A | 250VAC - Max | 1250VA | 33 mA | Non Latching | Lighted Indicator | Screw Terminal | - | - | - | - | - | - | -25°C ~ 50°C | Silver Nickel (AgNi) | General Purpose | - | - |
|
1449270000RSM-16 48V+ 2CO S |
2,311 | - |
|
Datasheet | RSM | Box | Active | DIN Rail | 48VDC | DPDT (2 Form C) x 16 | 5 A | 250VAC - Max | 1250VA | 8.7 mA | Non Latching | Lighted Indicator | Screw Terminal | - | - | - | - | - | - | -25°C ~ 50°C | Silver Nickel (AgNi) | General Purpose | - | - |
|
1449280000RSM-16 48V- 2CO S |
2,119 | - |
|
Datasheet | RSM | Box | Active | DIN Rail | 48VDC | DPDT (2 Form C) x 16 | 5 A | 250VAC - Max | 1250VA | 8.7 mA | Non Latching | Lighted Indicator | Screw Terminal | - | - | - | - | - | - | -25°C ~ 50°C | Silver Nickel (AgNi) | General Purpose | - | - |
|
1449180000RSM-16 12V- 2CO S |
2,660 | - |
|
Datasheet | RSM | Box | Active | DIN Rail | 12VDC | DPDT (2 Form C) x 16 | 5 A | 250VAC - Max | 1250VA | 33 mA | Non Latching | Lighted Indicator | Screw Terminal | - | - | - | - | - | - | -25°C ~ 50°C | Silver Nickel (AgNi) | General Purpose | - | - |
Power Relays, Over 2 Amps FAQ
Common questions about filtering, comparing and sourcing Power Relays, Over 2 Amps components.
How can I narrow the Power Relays, Over 2 Amps selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Power Relays, Over 2 Amps part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.