Power Transformers
Browse available Power Transformers part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Voltage - Primary | Voltage - Secondary (Full Load) | Current - Output (Max) | Primary Winding(s) | Secondary Winding(s) | Center Tap | Power - Max | Mounting Type | Termination Style | Size / Dimension | Height - Seated (Max) | Voltage - Isolation | Weight |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
E350WAPWR XFMR LAMINATED 350VA CHAS MT |
4,641 | - |
|
Datasheet | SBE | Bulk | Active | Laminated Core | - | - | - | - | - | No | 350VA | Chassis Mount | Solder, Quick Connect | 133.40mm L x 128.80mm W | - | - | - |
|
E350WBPWR XFMR LAMINATED 350VA CHAS MT |
4,326 | - |
|
Datasheet | SBE | Bulk | Active | Laminated Core | - | - | - | - | - | No | 350VA | Chassis Mount | Solder, Quick Connect | 133.40mm L x 128.80mm W | - | - | - |
|
|
0400MD-1-003PWR XFMR TOROIDAL 400VA CHAS MT |
2,710 | - |
|
Datasheet | MD | Box | Active | Toroidal | 100V, 120V, 200V, 240V | Parallel 120V, Series 240V | Parallel 3.33A, Series 1.67A | Dual, Multiple Taps | Single, Multiple Taps | No | 400VA | Chassis Mount | Wire Leads | 132.00mm Dia x 64.00mm W | - | 5000Vrms | 7.5 lbs (3.4 kg) |
|
M4L-3-10-115M4L 1000VA WITH INPUT 100/115/20 |
3,571 | - |
|
Datasheet | M4L | Tray | Active | - | 115V, 100V | Parallel 115V, Series 230V | Parallel 8.7A, Series 4.35A | Dual, Multiple Taps | Dual | No | 1000VA | Chassis Mount | Terminal Block | 144.78mm L x 124.21mm W | 133.35mm | 4000V | - |
|
M4L-3-10-230M4L 1000VA WITH INPUT 100/115/20 |
4,726 | - |
|
Datasheet | M4L | Tray | Active | - | 115V, 100V | 230V | 4.35A | Dual, Multiple Taps | Single | No | 1000VA | Chassis Mount | Terminal Block | 144.78mm L x 124.21mm W | 133.35mm | 4000V | - |
|
|
MPI-400-10PWR XFMR LAMINATED 400VA CHAS MT |
3,915 | - |
|
Datasheet | MPI | Bulk | Active | Laminated Core | 100V, 115V, 200V, 215V, 230V | Parallel 5V, Series 10V | Parallel 80A, Series 40A | Dual, Multiple Taps | Dual | No | 400VA | Chassis Mount | Terminal Block | 104.80mm L x 128.10mm W | 98.20mm | 4000Vrms | 9.9 lbs (4.5 kg) |
|
|
MPI-400-12PWR XFMR LAMINATED 400VA CHAS MT |
4,401 | - |
|
Datasheet | MPI | Bulk | Active | Laminated Core | 100V, 115V, 200V, 215V, 230V | Parallel 6V, Series 12V | Parallel 66.6A, Series 33.3A | Dual, Multiple Taps | Dual | No | 400VA | Chassis Mount | Terminal Block | 104.80mm L x 128.10mm W | 98.20mm | 4000Vrms | 9.9 lbs (4.5 kg) |
|
|
MPI-400-16PWR XFMR LAMINATED 400VA CHAS MT |
1,259 | - |
|
Datasheet | MPI | Bulk | Active | Laminated Core | 100V, 115V, 200V, 215V, 230V | Parallel 8V, Series 16V | Parallel 50A, Series 25A | Dual, Multiple Taps | Dual | No | 400VA | Chassis Mount | Terminal Block | 104.80mm L x 128.10mm W | 98.20mm | 4000Vrms | 9.9 lbs (4.5 kg) |
|
|
MPI-400-20PWR XFMR LAMINATED 400VA CHAS MT |
4,091 | - |
|
Datasheet | MPI | Bulk | Active | Laminated Core | 100V, 115V, 200V, 215V, 230V | Parallel 10V, Series 20V | Parallel 40A, Series 20A | Dual, Multiple Taps | Dual | No | 400VA | Chassis Mount | Terminal Block | 104.80mm L x 128.10mm W | 98.20mm | 4000Vrms | 9.9 lbs (4.5 kg) |
|
MT0150KPWR XFMR 150VA CHAS MT |
3,679 | - |
|
Datasheet | US2 | Box | Active | - | 600V | 24V | - | - | - | No | 150VA | Chassis Mount | Terminal Block | - | - | - | - |
|
XF-00225-2120PWR XFMR TOROIDAL 225VA CHAS MT |
1,124 | - |
|
Datasheet | - | Bulk | Active | Toroidal | 117V | Parallel 117V, Series 234V | Parallel 1.86A, Series 930mA | Dual | Dual | No | 225VA | Chassis Mount | Wire Leads | 116.84mm Dia | 55.88mm | 4000Vrms | 5.1 lbs (2.3 kg) |
|
MT0050LPWR XFMR 50VA CHAS MT |
1,584 | - |
|
Datasheet | - | Box | Active | - | 208V, 220V, 230V, 240V, 380V, 400V, 416V, 440V, 460V, 480V, 500V, 550V, 575V, 600V | 130V, 125V, 120V, 120V, 115V, 110V, 100V, 99V, 95V, 91V, 85V | - | - | - | No | 50VA | Chassis Mount | Terminal Block | 112.01mm L x 84.07mm W | 87.63mm | - | - |
|
A6X30133564PWR XFMR 200VA CHAS MT |
3,548 | - |
|
Datasheet | - | Box | Active | - | 120V, 240V | 24V | - | - | - | No | 200VA | Chassis Mount | Terminal Block | - | - | - | - |
|
265K234PWR XFMR 350VA CHAS MT |
3,989 | - |
|
Datasheet | 265 | Bulk | Active | - | 117V, 234V | Parallel 117V, Series 234V | Parallel 3A, Series 1.5A | Dual | Dual | Yes | 350VA | Chassis Mount | Wire Leads | 114.30mm L x 106.43mm W | 95.25mm | 2000Vrms | - |
|
M4L-3-10-32M4L 1000VA WITH INPUT 100/115/20 |
4,303 | - |
|
Datasheet | M4L | Tray | Active | - | 115V, 100V | 32V | 31.25A | Dual, Multiple Taps | Single | No | 1000VA | Chassis Mount | Terminal Block | 144.78mm L x 124.21mm W | 133.35mm | 4000V | - |
|
290YEXPWR XFMR CHAS MT |
4,545 | - |
|
Datasheet | 290 | Bulk | Active | - | 240V | 372V, 6.3V | 400mA, 4A | Single | Triple | Yes | - | Chassis Mount | Wire Leads | 87.33mm L x 129.54mm W | 104.78mm | 2500Vrms | - |
|
PWDI13205PWR XFMR |
4,820 | - |
|
Datasheet | * | Case | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
290XXBPWR XFMR CHAS MT |
1,463 | - |
|
Datasheet | 290 | Bulk | Active | - | 117V | 260V, 6.3V | 170mA, 3A | Single | Dual | Yes | - | Chassis Mount | Wire Leads | 76.20mm L x 63.50mm W | 29.34mm | 2500Vrms | - |
|
290DHXPWR XFMR CHAS MT |
3,855 | - |
|
Datasheet | 290 | Bulk | Active | - | 120V | 315V, 26V, 6V, 6.3V | 250mA, 100mA, 1A, 5A | Single | Four | Yes | - | Chassis Mount | Wire Leads | 95.25mm L x 87.63mm W | 80.01mm | - | - |
|
PWDP13135PWR XFMR LAMINATED CHAS MT |
1,886 | - |
|
Datasheet | PWDAHL | Case | Active | Laminated Core | 120V | - | - | Dual | Triple | Yes | - | Chassis Mount | Wire Leads | - | - | - | - |
Power Transformers FAQ
Common questions about selecting, comparing and sourcing Power Transformers components through Winsun (HK) Electronics.
What should I check when selecting Power Transformers components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Power Transformers part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Power Transformers parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Power Transformers components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.