Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
EXPLORE COMPONENTS

Thermostats - Mechanical

Browse available Thermostats - Mechanical part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.

For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.

Compare Part Numbers Review available models and manufacturers
Datasheets & Specifications Access technical references quickly
RFQ & BOM Support Send quantities for sourcing and quotation
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status Circuit Switching Temperature Reset Temperature Current Rating - AC Current Rating - DC Tolerance Switching Cycles Termination Style Mounting Type
2450   70430835 Honeywell Sensing and Productivity Solutions

2450 70430835

THERMOSTAT CATALOG LISTING

Honeywell Sensing and Productivity Solutions

3,620 -
Datasheet * - Bulk Active - - - - - - - - -
67L055-0398 Sensata-Airpax

67L055-0398

THERMOSTAT 55DEG C NC TO220-2

Sensata-Airpax

4,075 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 131°F (55°C) 86°F (30°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L068-0114 Sensata-Airpax

67L068-0114

THERMOSTAT 68DEG C NC TO220-2

Sensata-Airpax

4,517 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 154°F (68°C) - - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L075-0037 Sensata-Airpax

67L075-0037

THERMOSTAT 75DEG C NC TO220-2

Sensata-Airpax

1,360 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 167°F (75°C) 122°F (50°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L075-0048 Sensata-Airpax

67L075-0048

THERMOSTAT 75DEG C NC TO220-2

Sensata-Airpax

4,247 -
Datasheet 6700 TO-220-2 Tube Active SPST-NC 167°F (75°C) 122°F (50°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L080-0107 Sensata-Airpax

67L080-0107

THERMOSTAT 80DEG C NC TO220-2

Sensata-Airpax

4,157 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 176°F (80°C) 131°F (55°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L080-0314 Sensata-Airpax

67L080-0314

THERMOSTAT 80DEG C NC TO220-2

Sensata-Airpax

3,046 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 176°F (80°C) 131°F (55°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L085-0431 Sensata-Airpax

67L085-0431

THERMOSTAT 85DEG C NC TO220-2

Sensata-Airpax

1,759 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 185°F (85°C) 131°F (55°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L090-0160 Sensata-Airpax

67L090-0160

THERMOSTAT 90DEG C NC TO220-2

Sensata-Airpax

2,656 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 194°F (90°C) 140°F (60°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L092-0177 Sensata-Airpax

67L092-0177

THERMOSTAT 92DEG C NC TO220-2

Sensata-Airpax

3,005 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 198°F (92°C) 140°F (60°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L095-0118 Sensata-Airpax

67L095-0118

THERMOSTAT 95DEG C NC TO220-2

Sensata-Airpax

2,058 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 203°F (95°C) 140°F (60°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L095-0298 Sensata-Airpax

67L095-0298

THERMOSTAT 95DEG C NC TO220-2

Sensata-Airpax

4,274 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 203°F (95°C) 140°F (60°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L096-0119 Sensata-Airpax

67L096-0119

THERMOSTAT 96DEG C NC TO220-2

Sensata-Airpax

2,198 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 205°F (96°C) - - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L105-0176 Sensata-Airpax

67L105-0176

THERMOSTAT 105DEG C NC TO220-2

Sensata-Airpax

1,168 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 221°F (105°C) 158°F (70°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L115-0134 Sensata-Airpax

67L115-0134

THERMOSTAT 115DEG C NC TO220-2

Sensata-Airpax

2,246 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 240°F (115°C) 176°F (80°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L115-0396 Sensata-Airpax

67L115-0396

THERMOSTAT 115DEG C NC TO220-2

Sensata-Airpax

2,727 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 240°F (115°C) 176°F (80°C) - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
67L118-0184 Sensata-Airpax

67L118-0184

THERMOSTAT 118DEG C NC TO220-2

Sensata-Airpax

1,897 -
Datasheet 6700 TO-220-2 Tube Obsolete SPST-NC 244°F (118°C) - - 0.5A (48V) ±9°F (±5°C) 20K PC Pins Through Hole
2455R--93260965 Honeywell Sensing and Productivity Solutions

2455R--93260965

THERMAL-COMMERCIAL THERMAL

Honeywell Sensing and Productivity Solutions

4,304 -
Datasheet 2455R Cylinder with Mounting Flange Bulk Active SPST-NC - 120°F (49°C) 7.2A (277V), 10A (240V), 15A (120V) - - 6K Quick Connect Chassis Mount
2450R  70820142 Honeywell Sensing and Productivity Solutions

2450R 70820142

THERMOSTAT COMMERCIAL

Honeywell Sensing and Productivity Solutions

2,828 -
Datasheet * - Bulk Active - - - - - - - - -
2455R--91610926 Honeywell Sensing and Productivity Solutions

2455R--91610926

COMMERCIAL THERMOSTAT

Honeywell Sensing and Productivity Solutions

4,229 -
Datasheet 2455R Cylinder with Mounting Flange Bulk Active SPST-NC - 120°F (49°C) 7.2A (277V), 10A (240V), 15A (120V) - - 6K Quick Connect Chassis Mount
Total 1351 Record«Prev1... 4546474849505152...68Next»
WINSUN SOURCING SUPPORT

Need Thermostats - Mechanical Sourcing Support?

Send the manufacturer, part number, quantity and target delivery requirement. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and hard-to-find or obsolete components.

Global component sourcing support BOM, shortage and EOL support
FREQUENTLY ASKED QUESTIONS

Thermostats - Mechanical FAQ

Common questions about selecting, comparing and sourcing Thermostats - Mechanical components through Winsun (HK) Electronics.

What should I check when selecting Thermostats - Mechanical components?

Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.

Can Winsun help source specific Thermostats - Mechanical part numbers?

Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.

Do you support shortage, obsolete or hard-to-find Thermostats - Mechanical parts?

Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.

How do I request a quote for Thermostats - Mechanical components?

Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.