| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Type | Holding Temperature | Rated Functioning Temperature | Reset Temperature | Voltage Rating - AC | Voltage Rating - DC | Current Rating (Amps) | Approval Agency | Maximum Temperature Limit |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
EYP-2BN135TCO 250VAC 2A 140C (284F) AXIAL |
6,507 | - |
|
Datasheet | Axial | N | Bulk | Obsolete | Fuse | 115°C (239°F) | 140°C (284°F) | - | 250.0 | 50.0 | 2 A | BEAB, CCC, CSA, PSE, UL, VDE | 200°C (392°F) |
|
EYP-2BN163TCO 250VAC 2A 168C (334F) AXIAL |
9,873 | - |
|
Datasheet | Axial | N | Bulk | Obsolete | Fuse | 135°C (275°F) | 168°C (334°F) | - | 250.0 | 50.0 | 2 A | BEAB, CCC, CSA, PSE, UL, VDE | 200°C (392°F) |
|
EYP-2BN183TCO 250VAC 2A 188C AXIAL |
3,844 | - |
|
Datasheet | Axial | - | Bulk | Obsolete | Fuse | - | - | - | - | - | - | - | - |
|
EYP-2BN143TCO 250VAC 2A 145C (293F) AXIAL |
3,600 | - |
|
Datasheet | Axial | N | Bulk | Obsolete | Fuse | 120°C (248°F) | 145°C (293°F) | - | 250.0 | 50.0 | 2 A | BEAB, CCC, CSA, PSE, UL, VDE | 200°C (392°F) |
|
SDF DF066STCO 250VAC 10A 66C (151F) AXIAL |
4,472 | - |
|
Datasheet | Axial | SDF | Bulk | Active | Fuse | 42°C (108°F) | 66°C (151°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, UL, VDE | - |
|
SDF DF110STCO 250VAC 10A 110C (230F) AXIAL |
9,559 | - |
|
Datasheet | Axial | SDF | Bulk | Active | Fuse | 86°C (187°F) | 110°C (230°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, UL, VDE | - |
|
SDF DF170STCO 250VAC 10A 170C (338F) AXIAL |
8,380 | - |
|
Datasheet | Axial | SDF | Bulk | Active | Fuse | 146°C (295°F) | 170°C (338°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, UL, VDE | - |
|
SDF DF216STCO 250VAC 10A 216C (421F) AXIAL |
3,222 | - |
|
Datasheet | Axial | SDF | Bulk | Active | Fuse | 191°C (376°F) | 216°C (421°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, UL, VDE | - |
|
SDF DF228STCO 250VAC 10A 228C (442F) AXIAL |
4,972 | - |
|
Datasheet | Axial | SDF | Bulk | Active | Fuse | 193°C (379°F) | 228°C (442°F) | - | 250.0 | - | 10 A | CCC, cUL, PSE, UL, VDE | - |
|
MTKF K3FTHERMAL CUT OFF |
5,195 | - |
|
Datasheet | Axial | MT | Bulk | Active | Fuse | 99°C (210°F) | 115°C (239°F) | - | 250.0 | - | 1 A | UL, VDE | 200°C (392°F) |
|
|
EYP-2MT092BTCO 50VDC 2A 92C (198F) STRAP |
9,060 | - |
|
Datasheet | Strap | MT | Bulk | Obsolete | Fuse | 60°C (140°F) | 92°C (198°F) | - | - | 50.0 | 2 A | UL | 150°C (302°F) |
|
|
EYP-2MT098TCO 50VDC 2A 98C (208F) STRAP |
3,713 | - |
|
Datasheet | Strap | MT | Bulk | Obsolete | Fuse | 65°C (149°F) | 98°C (208°F) | - | - | 50.0 | 2 A | UL | 150°C (302°F) |
|
|
EYP-2MT098ATCO 50VDC 2A 98C (208F) STRAP |
5,388 | - |
|
Datasheet | Strap | MT | Bulk | Obsolete | Fuse | 65°C (149°F) | 98°C (208°F) | - | - | 50.0 | 2 A | UL | 150°C (302°F) |
|
|
EYP-2MT102ATCO 50VDC 2A 102C (216F) STRAP |
5,803 | - |
|
Datasheet | Strap | MT | Bulk | Obsolete | Fuse | 70°C (158°F) | 102°C (216°F) | - | - | 50.0 | 2 A | UL | 150°C (302°F) |
|
|
EYP-2MT102BTCO 50VDC 2A 102C (216F) STRAP |
2,848 | - |
|
Datasheet | Strap | MT | Bulk | Obsolete | Fuse | 70°C (158°F) | 102°C (216°F) | - | - | 50.0 | 2 A | UL | 150°C (302°F) |
|
|
EYP-2MT092TCO 50VDC 2A 92C (198F) STRAP |
2,834 | - |
|
Datasheet | Strap | MT | Bulk | Obsolete | Fuse | 60°C (140°F) | 92°C (198°F) | - | - | 50.0 | 2 A | UL | 150°C (302°F) |
|
|
EYP-2MT098BTCO 50VDC 2A 98C (208F) STRAP |
3,627 | - |
|
Datasheet | Strap | MT | Bulk | Obsolete | Fuse | 65°C (149°F) | 98°C (208°F) | - | - | 50.0 | 2 A | UL | 150°C (302°F) |
|
|
EYP-2MT102TCO 50VDC 2A 102C (216F) STRAP |
7,634 | - |
|
Datasheet | Strap | MT | Bulk | Obsolete | Fuse | 70°C (158°F) | 102°C (216°F) | - | - | 50.0 | 2 A | UL | 150°C (302°F) |
|
CB77A1BTCO 28VDC 25A 77C (171F) |
9,288 | - |
|
Datasheet | Nonstandard | CB | Bag | Active | Breaker | 25°C (77°F) | 77°C (171°F) | 40°C (104°F) | - | 28.0 | 25 A | cUL, TUV, UL | - |
|
CB85A1BTCO 28VDC 25A 85C (185F) |
5,539 | - |
|
Datasheet | Nonstandard | CB | Bag | Active | Breaker | 25°C (77°F) | 85°C (185°F) | 40°C (104°F) | - | 28.0 | 25 A | cUL, TUV, UL | - |
Thermal Cutoffs (Thermal Fuses) FAQ
Common questions about selecting, comparing and sourcing Thermal Cutoffs (Thermal Fuses) components through Winsun (HK) Electronics.
What should I check when selecting Thermal Cutoffs (Thermal Fuses) components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Thermal Cutoffs (Thermal Fuses) part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Thermal Cutoffs (Thermal Fuses) parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Thermal Cutoffs (Thermal Fuses) components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.