| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
T16M35T800UBTHYRISTOR TO220AB TUBE 50PCS |
9,449 | - |
|
Datasheet | - | TO-220-3 | Bulk | Active | Standard | 800 V | 16 A | 1.5 V | 130A @ 50Hz, 130A @ 60Hz | 35 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO220AB (Type WX) |
|
T16M10T800UBTHYRISTOR TO220AB TUBE 50PCS |
2,964 | - |
|
Datasheet | - | TO-220-3 | Bulk | Active | Standard | 800 V | 16 A | 1.5 V | 130A @ 50Hz, 130A @ 60Hz | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO220AB (Type WX) |
|
L6008D6TPTRIAC SENS GATE 600V 8A TO252 |
8,473 | - |
|
Datasheet | - | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Active | Logic - Sensitive Gate | 600 V | 8 A | 1.3 V | 65A, 85A | 5 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
L6008V6TPTRIAC SENS GATE 600V 8A TO251 |
7,476 | - |
|
Datasheet | - | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Logic - Sensitive Gate | 600 V | 8 A | 1.3 V | 65A, 85A | 5 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-251 (V-Pak/I-Pak) |
|
Q8004D4TPTRIAC 800V 4A TO252 |
9,960 | - |
|
Datasheet | - | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Active | Standard | 800 V | 4 A | 1.3 V | 46A, 55A | 25 mA | 30 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
Q8004V4TPTRIAC 800V 4A TO251 |
9,374 | - |
|
Datasheet | - | TO-251-3 Short Leads, IPAK, TO-251AA | Tube | Active | Standard | 800 V | 4 A | 1.3 V | 46A, 55A | 25 mA | 30 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-251 (V-Pak/I-Pak) |
|
Q8006DH4RPTRIAC ALTERNISTOR 800V 6A TO252 |
6,988 | - |
|
Datasheet | - | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tape & Reel (TR) | Active | Alternistor - Snubberless | 800 V | 6 A | 1.3 V | 55A, 65A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
MAC16HCDGTRIAC 400V 16A TO220AB |
4,821 | - |
|
Datasheet | - | TO-220-3 | Tube | Active | Standard | 400 V | 16 A | 1.5 V | 150A @ 60Hz | 50 mA | 50 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
QJ6006DH3TPTRIAC ALTERNISTOR 600V 6A TO252 |
9,139 | - |
|
Datasheet | QJxx06xHx | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Active | Alternistor - Snubberless | 600 V | 6 A | 1.3 V | 60A, 72A | 10 mA | 25 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-252 (DPAK) |
|
CTB16-1200CPTTRIAC 1.2KV 16A TO220AB |
5,235 | - |
|
Datasheet | - | TO-220-3 | Tube | Obsolete | Standard | 1.2 kV | 16 A | 1.3 V | 160A, 168A | 25 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
QJ6006DH2TPTRIAC ALTERNSTR 600V 6A TO252AA |
4,759 | - |
|
Datasheet | QJxx06xHx | TO-252-3, DPAK (2 Leads + Tab), SC-63 | Tube | Active | Alternistor - Snubberless | 600 V | 6 A | 1.3 V | 60A, 72A | 10 mA | 25 mA | Single | -40°C ~ 150°C (TJ) | - | - | Surface Mount | TO-252AA |
|
L4006L8TPTRIAC SENS GATE 400V 6A ITO220AB |
6,089 | - |
|
Datasheet | Lxx06xx | TO-220-3 Full Pack, Isolated Tab | Tube | Active | Logic - Sensitive Gate | 400 V | 6 A | 1.3 V | 50A, 60A | 10 mA | 20 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | ITO-220AB |
|
Q6008LH453TRIAC ALTERNISTOR 600V 8A TO220 |
6,169 | - |
|
Datasheet | - | TO-220-3 Isolated Tab, Formed Leads | Bulk | Obsolete | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 83A, 100A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
Q6008LH458TRIAC ALTERNISTOR 600V 8A TO220 |
2,578 | - |
|
Datasheet | - | TO-220-3 Isolated Tab, Formed Leads | Bulk | Obsolete | Alternistor - Snubberless | 600 V | 8 A | 1.3 V | 83A, 100A | 35 mA | 35 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 Isolated Tab |
|
Q6004R4TPTRIAC 600V 4A TO220AB |
8,382 | - |
|
Datasheet | Qxx04xx | TO-220-3 | Tube | Active | Standard | 600 V | 4 A | 1.3 V | 46A, 55A | 25 mA | 30 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
TMB166S-LTRIAC 600V 16A TO220F |
8,180 | - |
|
Datasheet | - | TO-220-3 Full Pack | Bulk | Obsolete | Standard | 600 V | 16 A | 1.5 V | 160A, 168A | 30 mA | - | Single | -40°C ~ 150°C (TJ) | - | - | Through Hole | TO-220F |
|
L4004R5TPTRIAC SENS GATE 400V 4A TO220AB |
5,752 | - |
|
Datasheet | Lxx04xx | TO-220-3 | Tube | Active | Logic - Sensitive Gate | 400 V | 4 A | 1.3 V | 33A, 40A | 5 mA | 10 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220AB |
|
CTB12-1200SWPTTRIAC SENS GATE 1.2KV 12A TO220 |
2,223 | - |
|
Datasheet | - | TO-220-3 | Tube | Obsolete | Logic - Sensitive Gate | 1.2 kV | 12 A | 1.3 V | 120A, 126A | 10 mA | 15 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220AB |
|
|
ACST6-7STTRIAC SENS GATE 700V 6A TO220 |
7,857 | - |
|
Datasheet | - | TO-220-3 | Tube | Obsolete | Logic - Sensitive Gate | 700 V | 6 A | 1.5 V | 45A, 50A | 10 mA | 25 mA | Single | -30°C ~ 125°C (TJ) | - | - | Through Hole | TO-220 |
|
ACST6-7SRTRIAC SENS GATE 700V 6A I2PAK |
6,617 | - |
|
Datasheet | - | TO-262-3 Short Leads, I2PAK | Tube | Obsolete | Logic - Sensitive Gate | 700 V | 6 A | 1.5 V | 45A, 50A | 10 mA | 25 mA | Single | -30°C ~ 125°C (TJ) | - | - | Through Hole | I2PAK |
TRIACs FAQ
Common questions about selecting, comparing and sourcing TRIACs components through Winsun (HK) Electronics.
What should I check when selecting TRIACs components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific TRIACs part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find TRIACs parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for TRIACs components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.