TRIACs
Browse available TRIACs part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | Triac Type | Voltage - Off State | Current - On State (It (RMS)) (Max) | Voltage - Gate Trigger (Vgt) (Max) | Current - Non Rep. Surge 50, 60Hz (Itsm) | Current - Gate Trigger (Igt) (Max) | Current - Hold (Ih) (Max) | Configuration | Operating Temperature | Grade | Qualification | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CQ202-4DS-2TRIAC INT TRIGGER 400V 4A TO202 |
9,875 | - |
|
Datasheet | - | TO-202 Long Tab | Bulk | Obsolete | Internally Triggered | 400 V | 4 A | 1.75 V | - | 9 mA | 5 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-202 |
|
CQ92-2MTRIAC INT TRIGGER 600V 2A TO92-3 |
4,939 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 600 V | 2 A | 1.8 V | - | 8 mA | 5 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ92BTRIAC INT TRIGGER 200V 1A TO92-3 |
9,068 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 200 V | 1 A | 2 V | - | 5 mA | 5 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ92BTTRIAC INT TRIGGER 200V 1A TO92-3 |
4,526 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 200 V | 1 A | 2 V | - | 3 mA | 3 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ92DTRIAC INT TRIGGER 400V 1A TO92-3 |
9,426 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 400 V | 1 A | 2 V | - | 5 mA | 5 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ92D APMTRIAC INT TRIGGER 400V 1A TO92-3 |
7,553 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 400 V | 1 A | 2 V | - | 5 mA | 5 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ92DTTRIAC INT TRIGGER 400V 1A TO92-3 |
7,485 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 400 V | 1 A | 2 V | - | 3 mA | 3 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ92MTRIAC INT TRIGGER 600V 1A TO92-3 |
4,770 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 600 V | 1 A | 2 V | - | 5 mA | 5 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ92MTTRIAC INT TRIGGER 600V 1A TO92-3 |
7,394 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 600 V | 1 A | 2 V | - | 3 mA | 3 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ92NTRIAC INT TRIGGER 800V 1A TO92-3 |
4,660 | - |
|
Datasheet | - | TO-226-3, TO-92-3 (TO-226AA) | Bulk | Obsolete | Internally Triggered | 800 V | 1 A | 2 V | - | 5 mA | 5 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-92-3 |
|
CQ220-10DTRIAC INT TRIGGER 400V 10A TO220 |
7,118 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 400 V | 10 A | 1.5 V | - | 50 mA | 25 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-10MTRIAC INT TRIGGER 600V 10A TO220 |
3,611 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 600 V | 10 A | 1.5 V | - | 50 mA | 25 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-10NTRIAC INT TRIGGER 800V 10A TO220 |
2,701 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 800 V | 10 A | 1.5 V | - | 50 mA | 25 mA | Single | -40°C ~ 110°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-12DTRIAC INT TRIGGER 400V 12A TO220 |
8,675 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 400 V | 12 A | 2.5 V | - | 50 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-12MTRIAC INT TRIGGER 600V 12A TO220 |
9,270 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 600 V | 12 A | 2.5 V | - | 50 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-12M SLTRIAC INT TRIGGER 600V 12A TO220 |
2,326 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 600 V | 12 A | 2.5 V | - | 50 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-12NTRIAC INT TRIGGER 800V 12A TO220 |
5,821 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 800 V | 12 A | 2.5 V | - | 50 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-16MTRIAC INT TRIGGER 600V 16A TO220 |
4,127 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 600 V | 16 A | 2.5 V | - | 75 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-16M SLTRIAC INT TRIGGER 600V 16A TO220 |
9,171 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 600 V | 16 A | 2.5 V | - | 75 mA | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
|
CQ220-16NTRIAC INT TRIGGER 800V 16A TO220 |
7,477 | - |
|
Datasheet | - | TO-220-3 | Bulk | Obsolete | Internally Triggered | 800 V | 16 A | 2.5 V | - | - | 25 mA | Single | -40°C ~ 125°C (TJ) | - | - | Through Hole | TO-220-3 |
TRIACs FAQ
Common questions about selecting, comparing and sourcing TRIACs components through Winsun (HK) Electronics.
What should I check when selecting TRIACs components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific TRIACs part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find TRIACs parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for TRIACs components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.