| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Form | Number of Poles | Voltage - Continuous Operating (Max) (MCOV) | Current - Discharge (Nom) (8/20µS) | Current - Discharge (Max) (8/20µS) | Operating Temperature | Voltage - Protection Rating (VPR) | Voltage - Protection Level (VP) (2416) | Operating Temperature | Features | Mounting Type | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LSP10240PSPD TYPE 2 275VAC MCOV 1 POLE |
110 | - |
|
Datasheet | LSP | Tray | Active | Type 2 | Module Only | 1 | 275VAC | 10 kA | 20 kA | - | - | 1.2 kV | -45°C ~ 85°C | Thermally Protected | Screw | CE, cURus, UL |
|
BSP3-277SPD 320VAC/420VDC MCOV 3 POLE |
155 | - |
|
Datasheet | BSP3 | Box | Active | - | Module Only | 3 | 320VAC, 420VDC | 10 kA | 10 kA | - | - | - | - | - | Free Hanging | cURus, UL |
|
LSP10GIHP277SSPD TYPE 2/TYPE 3 320VAC MCOV |
497 | - |
|
Datasheet | LSP | Bulk | Active | Type 2, Type 3 | Module Only | 1 | 320VAC | 10 kA | 20 kA | - | - | 3.8 kV | -45°C ~ 75°C | Thermally Protected | Screw | cURus, KEMA-KEUR, UL |
|
1320-S-110SPD TYPE 2/TYPE 4 150VDC MCOV |
1,132 | - |
|
Datasheet | 1320 | Bulk | Active | Type 2, Type 4 | Base + Module | 2 | 150VDC | 20 kA | 40 kA | - | - | 500 V | -40°C ~ 85°C | Remote Signaling Contacts | DIN Rail | CE, CSA, UR |
|
2907916SPD TYPE 3 34VAC MCOV 1 POLE |
1,932 | - |
|
Datasheet | PLT-SEC | Bulk | Active | Type 3 | Base + Module | 1 | 34VAC | 1 kA | 4 kA | 10 kA | - | 600 V | -40°C ~ 80°C | - | DIN Rail | cUL, EAC, UL |
|
LSP10GI277SSPD TYPE 2 320VAC MCOV 1 POLE |
377 | - |
|
Datasheet | LSP | Bulk | Active | Type 2 | Module Only | 1 | 320VAC | 10 kA | 20 kA | - | - | 1.4 kV | -40°C ~ 85°C | Thermally Protected | Screw | UL |
|
1061385SPD 3VAC/5VDC MCOV 1 POLE |
135 | - |
|
Datasheet | - | Bulk | Active | - | Base + Module | 1 | 3VAC, 5VDC | 5 kA | 10 kA | - | - | 900 V | -40°C ~ 85°C | - | DIN Rail | cUL, UL |
|
1210-2S-230SPD TYPE 2/TYPE 4 275VAC MCOV |
2,859 | - |
|
Datasheet | 1210 | Bulk | Active | Type 2, Type 4 | Module Only | 2 | 275VAC | 20 kA | 100 kA | 100 kA | 900 V | 1.25 kV | -50°C ~ 85°C | Remote Signaling Contacts, Thermally Protected | DIN Rail | CE, CSA, UL |
|
SPD2-550-4P0-RSPD TYPE 1/TYPE 2 550VAC MCOV |
128 | - |
|
Datasheet | SPD2 4+0 | Bulk | Active | Type 1, Type 2 | Base + Module | 4 | 550VAC | 20 kA | 50 kA | 200 kA | 2 kV | 2.5 kV | -40°C ~ 80°C | Remote Signaling Contacts, Thermally Protected | DIN Rail | CE, cURus, UL, VDE |
|
LST1505VL2NT1SPD TYP 1/TYP 2/TYP4 150VAC MCOV |
125 | - |
|
Datasheet | LST | Tray | Active | Type 1, Type 2, Type 4 | Module Only | 1 | 150VAC | 20 kA | - | 200 kA | 600 V | - | -40°C ~ 85°C | Thermally Protected | Through Hole | UL |
|
LST2755VL2NT1SPD TYP 1/TYP 2/TYP4 275VAC MCOV |
776 | - |
|
Datasheet | LST | Tray | Active | Type 1, Type 2, Type 4 | Module Only | 1 | 275VAC | 20 kA | - | 200 kA | 900 V | - | -40°C ~ 85°C | Thermally Protected | Through Hole | UL |
|
LST1507VL2NT1SPD TYP 1/TYP 2/TYP4 150VAC MCOV |
130 | - |
|
Datasheet | LST | Tray | Active | Type 1, Type 2, Type 4 | Module Only | 1 | 150VAC | 20 kA | - | 200 kA | 600 V | - | -40°C ~ 85°C | Thermally Protected | Through Hole | UL |
|
LSP05G480SSPD TYPE 2 510VAC MCOV 1 POLE |
150 | - |
|
Datasheet | LSP | Bulk | Active | Type 2 | Module Only | 1 | 510VAC | 5 kA | 10 kA | - | - | - | -45°C ~ 85°C | Thermally Protected | - | cURus, IEC, IECEE, UL |
|
LSP05G347SSPD TYPE 2 420VAC MCOV 1 POLE |
145 | - |
|
Datasheet | LSP | Bulk | Active | Type 2 | Module Only | 1 | 420VAC | 5 kA | 10 kA | - | - | - | -45°C ~ 85°C | Thermally Protected | - | cURus, IEC, IECEE, UL |
|
1220-20-I4-120M2SPD TYPE 1/TYPE 4 150VAC MCOV |
1,191 | - |
|
Datasheet | 1220 | Box | Active | Type 1, Type 4 | Module Only | 1 | 150VAC | 20 kA | 50 kA | 200 kA | 600 V | - | -40°C ~ 85°C | Remote Signaling Contacts, Thermally Protected | Surface Mount | cURus |
|
ICL-16LSPD 264VAC MCOV 1 POLE |
4,415 | - |
|
Datasheet | ICL | Box | Active | - | Module Only | 1 | 264VAC | - | - | - | - | - | -30°C ~ 70°C | Thermally Protected | DIN Rail | CE, EAC |
|
1250A-1S-120SPD TYP 2/TYP 4 150V MCOV 1 POLE |
101 | - |
|
Datasheet | 1250A | Box | Active | Type 2, Type 4 | Base + Module | 1 | 150V | 20 kA | 50 kA | 200 kA | 700 V | - | -40°C ~ 85°C | Remote Signaling Contacts | DIN Rail | - |
|
1250A-1S-230SPD TYP 2/TYP 4 275V MCOV 1 POLE |
100 | - |
|
Datasheet | 1250A | Box | Active | Type 2, Type 4 | Base + Module | 1 | 275V | 20 kA | 50 kA | 200 kA | 1 kV | - | -40°C ~ 85°C | Remote Signaling Contacts | DIN Rail | - |
|
1250A-1S-400SPD TYP 2/TYP 4 420V MCOV 1 POLE |
2,617 | - |
|
Datasheet | 1250A | Box | Active | Type 2, Type 4 | Base + Module | 1 | 420V | 20 kA | 50 kA | 200 kA | 1.5 kV | - | -40°C ~ 85°C | Remote Signaling Contacts | DIN Rail | - |
|
2520-4L2-24SPD 33VDC MCOV 1 POLE |
1,558 | - |
|
Datasheet | 2520 | Box | Active | - | Base + Module | 1 | 33VDC | 10 kA | 20 kA | - | - | 55 V | -40°C ~ 85°C | - | DIN Rail | - |
Surge Protection Devices (SPDs) FAQ
Common questions about selecting, comparing and sourcing Surge Protection Devices (SPDs) components through Winsun (HK) Electronics.
What should I check when selecting Surge Protection Devices (SPDs) components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Surge Protection Devices (SPDs) part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Surge Protection Devices (SPDs) parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Surge Protection Devices (SPDs) components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.