Surge Protection Devices (SPDs)
Browse available Surge Protection Devices (SPDs) part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Form | Number of Poles | Voltage - Continuous Operating (Max) (MCOV) | Current - Discharge (Nom) (8/20µS) | Current - Discharge (Max) (8/20µS) | Operating Temperature | Voltage - Protection Rating (VPR) | Voltage - Protection Level (VP) (2416) | Operating Temperature | Features | Mounting Type | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SPD160480Y3J-NDSPD TYPE 2 640VAC MCOV 1 POLE |
5,349 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 160 kA | 200 kA | 1.8 kV | - | -40°C ~ 50°C | Remote Signaling Contacts | Chassis Mount | cURus, UL |
|
SPD160480Y3GSPD TYPE 2 640VAC MCOV 1 POLE |
6,245 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 160 kA | 200 kA | 2 kV | - | -40°C ~ 50°C | Visual Life Indicator | Chassis Mount | cULus, UL |
|
SPD160480D3CSPD TYPE 2 640VAC MCOV 1 POLE |
5,181 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 160 kA | 200 kA | 2.5 kV | - | -40°C ~ 50°C | Visual Life Indicator | Chassis Mount | cULus, UL |
|
BSPD200600Y3PSPD TYPE 2 200V MCOV 1 POLE |
5,168 | - |
|
Datasheet | BSPD | Bulk | Active | Type 2 | Base + Module | 1 | 200V | 20 kA | - | 200 kA | 2.5 kV | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL |
|
BSPD200480Y3PSPD TYPE 2 200V MCOV 1 POLE |
8,297 | - |
|
Datasheet | BSPD | Bulk | Active | Type 2 | Base + Module | 1 | 200V | 20 kA | - | 200 kA | 2.5 kV | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL |
|
SSP01SBA16DSPD TYPE 1 150V MCOV 1 POLE |
7,981 | - |
|
Datasheet | - | Box | Active | Type 1 | Module Only | 1 | 150V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - |
|
SSP04EMA12DSPD 320V MCOV 1 POLE |
5,017 | - |
|
Datasheet | - | Box | Active | - | Module Only | 1 | 320V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - |
|
SPD160230L3CSPD TYPE 2 MCOV 1 POLE |
7,142 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | - | 20 kA | 160 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD160240H3CSPD TYPE 2 300V MCOV 1 POLE |
2,659 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 160 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
BSPA200600Y7PSPD TYPE 2 840VAC MCOV 1 POLE |
5,870 | - |
|
Datasheet | BSPA | Bulk | Active | Type 2 | Module Only | 1 | 840VAC | 20 kA | - | 200 kA | 2.5 kV | - | -40°C ~ 60°C | Remote Signaling Contacts, Thermally Protected, Visual Life Indicator | Chassis Mount | CSA, UL |
|
BSPA200600D7PSPD TYPE 2 840VAC MCOV 1 POLE |
3,374 | - |
|
Datasheet | BSPA | Bulk | Active | Type 2 | Module Only | 1 | 840VAC | 20 kA | - | 200 kA | 2.5 kV | - | -40°C ~ 60°C | Remote Signaling Contacts, Thermally Protected, Visual Life Indicator | Chassis Mount | CSA, UL |
|
SSP08EMA16SPD 420V MCOV 1 POLE |
5,260 | - |
|
Datasheet | - | Box | Active | - | Module Only | 1 | 420V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - |
|
SPD100230L4MSPD 1 POLE |
6,177 | - |
|
Datasheet | SPD | Bulk | Active | - | Base + Module | 1 | - | 20 kA | 100 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SSP04EMA12FSPD 320V MCOV 1 POLE |
5,108 | - |
|
Datasheet | - | Box | Active | - | Module Only | 1 | 320V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - |
|
SPD200208Y3LSPD TYPE 2 300V MCOV 1 POLE |
5,007 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200600Y3LSPD TYPE 2 840V MCOV 1 POLE |
7,713 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 840V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200220Y3LSPD TYPE 2 300V MCOV 1 POLE |
5,546 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200600D3LSPD TYPE 2 840V MCOV 1 POLE |
2,588 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 840V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200240S3LSPD TYPE 2 300V MCOV 1 POLE |
2,306 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200400Y3LSPD TYPE 2 640V MCOV 1 POLE |
9,764 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 640V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
Surge Protection Devices (SPDs) FAQ
Common questions about selecting, comparing and sourcing Surge Protection Devices (SPDs) components through Winsun (HK) Electronics.
What should I check when selecting Surge Protection Devices (SPDs) components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Surge Protection Devices (SPDs) part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Surge Protection Devices (SPDs) parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Surge Protection Devices (SPDs) components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.