| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Form | Number of Poles | Voltage - Continuous Operating (Max) (MCOV) | Current - Discharge (Nom) (8/20µS) | Current - Discharge (Max) (8/20µS) | Operating Temperature | Voltage - Protection Rating (VPR) | Voltage - Protection Level (VP) (2416) | Operating Temperature | Features | Mounting Type | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SPD200208Y2OSPD TYPE 2 300V MCOV 1 POLE |
9,372 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200240D2OSPD TYPE 2 320V MCOV 1 POLE |
6,477 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 320V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200600D2OSPD TYPE 2 840V MCOV 1 POLE |
2,269 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 840V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200240S2OSPD TYPE 2 300V MCOV 1 POLE |
5,913 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200240H2OSPD TYPE 2 300V MCOV 1 POLE |
4,761 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200480D2OSPD TYPE 2 640VAC MCOV 1 POLE |
4,066 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 200 kA | 200 kA | 2.5 kV | - | -40°C ~ 50°C | Visual Life Indicator | Chassis Mount | cULus, UL |
|
SPD200400Y2OSPD TYPE 2 640VAC MCOV 1 POLE |
4,047 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 200 kA | 200 kA | 2.5 kV | - | -40°C ~ 50°C | Visual Life Indicator | Chassis Mount | cULus, UL |
|
SPD200480Y2OSPD TYPE 2 640VAC MCOV 1 POLE |
6,037 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Module Only | 1 | 640VAC | 20 kA | 200 kA | 200 kA | 2 kV | - | -40°C ~ 50°C | Visual Life Indicator | Chassis Mount | cULus, UL |
|
SPD120230L4NSPD 1 POLE |
8,045 | - |
|
Datasheet | SPD | Bulk | Active | - | Base + Module | 1 | - | 20 kA | 120 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPM100480Y3RSPD TYPE 2 MCOV 1 POLE |
4,113 | - |
|
Datasheet | Max | Bulk | Active | Type 2 | Base + Module | 1 | - | 20 kA | 100 kA | 200 kA | - | - | -20°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL |
|
SPM120208Y1TSPD TYPE 1 MCOV 1 POLE |
2,433 | - |
|
Datasheet | Max | Bulk | Active | Type 1 | Base + Module | 1 | - | 20 kA | 120 kA | 200 kA | - | - | -20°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL |
|
SPM120600D3TSPD TYPE 2 840V MCOV 1 POLE |
5,826 | - |
|
Datasheet | Max | Bulk | Active | Type 2 | Base + Module | 1 | 840V | 20 kA | 120 kA | 200 kA | - | - | -20°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL |
|
SPM100400Y3RSPD TYPE 2 640V MCOV 1 POLE |
3,829 | - |
|
Datasheet | Max | Bulk | Active | Type 2 | Base + Module | 1 | 640V | 20 kA | 100 kA | 200 kA | - | - | -20°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL |
|
SPM100240S3RSPD TYPE 2 300V MCOV 1 POLE |
7,669 | - |
|
Datasheet | Max | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 100 kA | 200 kA | - | - | -20°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL |
|
SPM120600Y1TSPD TYPE 1 840V MCOV 1 POLE |
8,859 | - |
|
Datasheet | Max | Bulk | Active | Type 1 | Base + Module | 1 | 840V | 20 kA | 120 kA | 200 kA | - | - | -20°C ~ 50°C | Thermally Protected | Chassis Mount | CSA, UL |
|
SSP01EMA12SDSPD 150V MCOV 1 POLE |
3,286 | - |
|
Datasheet | - | Box | Active | - | Module Only | 1 | 150V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - |
|
SSP02SBA16DSPD TYPE 1 150V MCOV 1 POLE |
3,857 | - |
|
Datasheet | - | Box | Active | Type 1 | Module Only | 1 | 150V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - |
|
SSP02EMA16DSPD 150V MCOV 1 POLE |
7,426 | - |
|
Datasheet | - | Box | Active | - | Module Only | 1 | 150V | 20 kA | - | 200 kA | - | - | - | - | DIN Rail | - |
|
SPD200208Y3PSPD TYPE 2 300V MCOV 1 POLE |
7,559 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 300V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
|
SPD200600Y3PSPD TYPE 2 840V MCOV 1 POLE |
5,519 | - |
|
Datasheet | SPD | Bulk | Active | Type 2 | Base + Module | 1 | 840V | 20 kA | 200 kA | 200 kA | - | - | -40°C ~ 50°C | Thermally Protected | Chassis Mount | cURus, UL |
Surge Protection Devices (SPDs) FAQ
Common questions about selecting, comparing and sourcing Surge Protection Devices (SPDs) components through Winsun (HK) Electronics.
What should I check when selecting Surge Protection Devices (SPDs) components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Surge Protection Devices (SPDs) part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Surge Protection Devices (SPDs) parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Surge Protection Devices (SPDs) components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.