For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.

Compare Part Numbers Review available models and manufacturers
Datasheets & Specifications Access technical references quickly
RFQ & BOM Support Send quantities for sourcing and quotation
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Form Number of Poles Voltage - Continuous Operating (Max) (MCOV) Current - Discharge (Nom) (8/20µS) Current - Discharge (Max) (8/20µS) Operating Temperature Voltage - Protection Rating (VPR) Voltage - Protection Level (VP) (2416) Operating Temperature Features Mounting Type Approval Agency
1280-2S-127 Bourns Inc.

1280-2S-127

SPD TYPE 1/TYPE 2 180VAC MCOV

Bourns Inc.

2,721 -
Datasheet 1280 Box Active Type 1, Type 2 Base + Module 2 180VAC 20 kA 50 kA 25 kA - 1 kV -40°C ~ 85°C Remote Signaling Contacts DIN Rail -
1280-2S-400 Bourns Inc.

1280-2S-400

SPD TYPE 1/TYPE 2 440VAC MCOV

Bourns Inc.

7,869 -
Datasheet 1280 Box Active Type 1, Type 2 Base + Module 2 440VAC 20 kA 50 kA 25 kA - 2 kV -40°C ~ 85°C Remote Signaling Contacts DIN Rail -
1280-2S-277 Bourns Inc.

1280-2S-277

SPD TYPE 1/TYPE 2 350VAC MCOV

Bourns Inc.

5,183 -
Datasheet 1280 Box Active Type 1, Type 2 Base + Module 2 350VAC 20 kA 50 kA 25 kA - 1.5 kV -40°C ~ 85°C Remote Signaling Contacts DIN Rail -
2591290000 Weidmüller

2591290000

SPD TYPE 2 750VAC MCOV 1 POLE

Weidmüller

2,161 -
Datasheet VPU AC II Bulk Active Type 2 Base + Module 1 750VAC 20 kA 35 kA 200 kA 2.5 kV 3.4 kV -40°C ~ 85°C - DIN Rail CE
SPOD150SR Eaton - Bussmann Electrical Division

SPOD150SR

SPD

Eaton - Bussmann Electrical Division

8,306 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD150S Eaton - Bussmann Electrical Division

SPOD150S

SPD

Eaton - Bussmann Electrical Division

7,984 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD320SR Eaton - Bussmann Electrical Division

SPOD320SR

SPD

Eaton - Bussmann Electrical Division

5,002 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD150ST Eaton - Bussmann Electrical Division

SPOD150ST

SPD

Eaton - Bussmann Electrical Division

7,059 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD320S Eaton - Bussmann Electrical Division

SPOD320S

SPD

Eaton - Bussmann Electrical Division

2,291 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD320ST Eaton - Bussmann Electrical Division

SPOD320ST

SPD

Eaton - Bussmann Electrical Division

4,275 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
1270-1S-120 Bourns Inc.

1270-1S-120

SPD TYPE 1/TYPE 2 150VAC MCOV

Bourns Inc.

4,504 -
Datasheet 1270 Box Active Type 1, Type 2 Base + Module 1 150VAC 25 kA 80 kA 50 kA - 800 V -40°C ~ 85°C Remote Signaling Contacts DIN Rail -
1270-1S-127 Bourns Inc.

1270-1S-127

SPD TYPE 1/TYPE 2 180VAC MCOV

Bourns Inc.

7,695 -
Datasheet 1270 Box Active Type 1, Type 2 Base + Module 1 180VAC 25 kA 80 kA 50 kA - 1 kV -40°C ~ 85°C Remote Signaling Contacts DIN Rail -
1270-1S-277 Bourns Inc.

1270-1S-277

SPD TYPE 1/TYPE 2 350VAC MCOV

Bourns Inc.

6,965 -
Datasheet 1270 Box Active Type 1, Type 2 Base + Module 1 350VAC 25 kA 80 kA 50 kA - 1.5 kV -40°C ~ 85°C Remote Signaling Contacts DIN Rail -
1270-1S-400 Bourns Inc.

1270-1S-400

SPD TYPE 1/TYPE 2 440VAC MCOV

Bourns Inc.

9,740 -
Datasheet 1270 Box Active Type 1, Type 2 Base + Module 1 440VAC 25 kA 65 kA 50 kA - 2 kV -40°C ~ 85°C Remote Signaling Contacts DIN Rail -
1280-2S-480 Bourns Inc.

1280-2S-480

SPD TYPE 1/TYPE 2 600VAC MCOV

Bourns Inc.

9,804 -
Datasheet 1280 Box Active Type 1, Type 2 Base + Module 2 600VAC 20 kA 50 kA 25 kA - 2.5 kV -40°C ~ 85°C Remote Signaling Contacts DIN Rail -
SPOD270SR Eaton - Bussmann Electrical Division

SPOD270SR

SPD

Eaton - Bussmann Electrical Division

9,800 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD270STR Eaton - Bussmann Electrical Division

SPOD270STR

SPD

Eaton - Bussmann Electrical Division

9,589 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD550SR Eaton - Bussmann Electrical Division

SPOD550SR

SPD

Eaton - Bussmann Electrical Division

8,547 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD270S Eaton - Bussmann Electrical Division

SPOD270S

SPD

Eaton - Bussmann Electrical Division

3,966 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
SPOD510SR Eaton - Bussmann Electrical Division

SPOD510SR

SPD

Eaton - Bussmann Electrical Division

8,191 -
Datasheet * Bulk Obsolete - - - - - - - - - - - - -
Total 9062 Record«Prev1... 5051525354555657...454Next»
WINSUN SOURCING SUPPORT

Need Surge Protection Devices (SPDs) Sourcing Support?

Send the manufacturer, part number, quantity and target delivery requirement. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and hard-to-find or obsolete components.

Global component sourcing support BOM, shortage and EOL support
FREQUENTLY ASKED QUESTIONS

Surge Protection Devices (SPDs) FAQ

Common questions about selecting, comparing and sourcing Surge Protection Devices (SPDs) components through Winsun (HK) Electronics.

What should I check when selecting Surge Protection Devices (SPDs) components?

Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.

Can Winsun help source specific Surge Protection Devices (SPDs) part numbers?

Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.

Do you support shortage, obsolete or hard-to-find Surge Protection Devices (SPDs) parts?

Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.

How do I request a quote for Surge Protection Devices (SPDs) components?

Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.