| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Form | Number of Poles | Voltage - Continuous Operating (Max) (MCOV) | Current - Discharge (Nom) (8/20µS) | Current - Discharge (Max) (8/20µS) | Operating Temperature | Voltage - Protection Rating (VPR) | Voltage - Protection Level (VP) (2416) | Operating Temperature | Features | Mounting Type | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
1250A-4S-480SPD TYP 2/TYP 4 550V MCOV 4 POLE |
3,678 | - |
|
Datasheet | 1250A | Box | Active | Type 2, Type 4 | Base + Module | 4 | 550V | 20 kA | 50 kA | 200 kA | 1.8 kV | - | -40°C ~ 85°C | Remote Signaling Contacts, Visual Life Indicator | DIN Rail | - |
|
DS50VGPVS-1500G/51SPD TYPE 2 1.5KV MCOV 1 POLE |
4,855 | - |
|
Datasheet | - | Active | Type 2 | Base + Module | 1 | 1.5kV | 15 kA | 40 kA | - | - | 6.8 kV | -40°C ~ 85°C | Remote Signaling Contacts | DIN Rail | CE, EAC, UR | |
|
DS50VGPVS-1000SPD 1.2VDC MCOV 1 POLE |
3,243 | - |
|
Datasheet | - | Active | - | Base + Module | 1 | 1.2VDC | 20 kA | - | - | - | 3.6 kV | -50°C ~ 85°C | - | DIN Rail | CE, CSA, cURus | |
|
2910378SPD TYPE 2 385VAC MCOV 1 POLE |
7,651 | - |
|
Datasheet | VAL-US | Bulk | Active | Type 2 | Base + Module | 1 | 385VAC | 15 kA | 80 kA | 25 kA | 2.5 kV | 4 kV | -40°C ~ 80°C | - | DIN Rail | cUL, UL |
|
2800986SPD 37VAC/53VDC MCOV 1 POLE |
2,528 | - |
|
Datasheet | PT | Bulk | Active | - | Base + Module | 1 | 37VAC, 53VDC | 10 kA | 20 kA | - | - | 800 V | -40°C ~ 70°C | - | DIN Rail | cCSAus, CSA, EAC, UL |
|
SPD2-300-3P1SPD TYP 1/TYP 2 300V MCOV 3 POLE |
3,686 | - |
|
Datasheet | SPD2 3P+1 | Bulk | Active | Type 1, Type 2 | Base + Module | 3 | 300V | 20 kA | 50 kA | 150 kA | 900 V | 1.5 kV | -40°C ~ 80°C | Thermally Protected, Visual Life Indicator | DIN Rail | CE, cURus, UL, VDE |
|
M9L23240SPD TYPE 1 550VAC MCOV 3 POLE |
8,846 | - |
|
Datasheet | - | Box | Active | Type 1 | Base + Module | 3 | 550VAC | 20 kA | 75 kA | 200 kA | - | 1.8 kV | -25°C ~ 60°C | - | DIN Rail | - |
|
2801219SPD 37VAC/53VDC MCOV 1 POLE |
7,172 | - |
|
Datasheet | PT | Bulk | Active | - | Base + Module | 1 | 37VAC, 53VDC | 10 kA | 20 kA | - | - | 160 V | -40°C ~ 70°C | - | DIN Rail | UL |
|
BSPM3480WYGSPD TYPE 2 1.2KVAC MCOV 3 POLE |
7,323 | - |
|
Datasheet | BSPM | Bulk | Obsolete | Type 2 | Base + Module | 3 | 1.2kVAC | 20 kA | 40 kA | 200 kA | 4 kV | - | - | Remote Signaling Contacts, Thermally Protected | DIN Rail | CE, cURus, UL |
|
M9L17208SPD TYPE 1 350VAC MCOV 4 POLE |
5,101 | - |
|
Datasheet | - | Box | Active | Type 1 | Base + Module | 4 | 350VAC | 20 kA | 75 kA | 200 kA | - | 1.2 kV | -25°C ~ 60°C | - | DIN Rail | - |
|
M9L57690SPD TYPE 1 1.1KVAC MCOV 4 POLE |
9,535 | - |
|
Datasheet | - | Box | Active | Type 1 | Base + Module | 4 | 1.1kVAC | 20 kA | 75 kA | 200 kA | - | 3 kV | -25°C ~ 60°C | - | DIN Rail | - |
|
M9L37480SPD TYPE 1 640VAC MCOV 4 POLE |
6,372 | - |
|
Datasheet | - | Box | Active | Type 1 | Base + Module | 4 | 640VAC | 20 kA | 75 kA | 200 kA | - | 2 kV | -25°C ~ 60°C | - | DIN Rail | - |
|
M9L47600SPD TYPE 1 2KVAC MCOV 1 POLE |
9,255 | - |
|
Datasheet | - | Box | Active | Type 1 | Base + Module | 1 | 2kVAC | 20 kA | 75 kA | - | - | 2.5 kV | -25°C ~ 60°C | - | DIN Rail | - |
|
M9L27480SPD TYPE 1 1.5KVAC MCOV 1 POLE |
9,162 | - |
|
Datasheet | - | Box | Active | Type 1 | Base + Module | 1 | 1.5kVAC | 10 kA | 75 kA | - | - | 2 kV | -25°C ~ 60°C | - | DIN Rail | - |
|
M9L17240SPD TYPE 1 1.2KVAC MCOV 1 POLE |
8,045 | - |
|
Datasheet | - | Box | Active | Type 1 | Base + Module | 1 | 1.2kVAC | 20 kA | 75 kA | - | - | 1.5 kV | -25°C ~ 60°C | - | DIN Rail | - |
|
G0073000SPD |
2,740 | - |
|
Datasheet | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
2801266SPD 37VAC/53VDC MCOV 1 POLE |
3,566 | - |
|
Datasheet | PT | Bulk | Active | - | Base + Module | 1 | 37VAC, 53VDC | 10 kA | 20 kA | - | - | 1.3 kV | -40°C ~ 70°C | - | DIN Rail | cCSAus, CSA, CSAus, UL |
|
2801260SPD 4VAC/6VDC MCOV 1 POLE |
7,611 | - |
|
Datasheet | PT | Bulk | Active | - | Base + Module | 1 | 4VAC, 6VDC | 10 kA | 20 kA | - | - | 1.3 kV | -40°C ~ 70°C | - | DIN Rail | UL |
|
2801220SPD 37VAC/53VDC MCOV 1 POLE |
9,358 | - |
|
Datasheet | PT | Bulk | Active | - | Base + Module | 1 | 37VAC, 53VDC | 10 kA | 20 kA | - | - | 950 V | -40°C ~ 70°C | - | DIN Rail | UL |
|
2730740000SPD TYPE 2 480VAC MCOV 4 POLE |
5,956 | - |
|
Datasheet | - | Box | Active | Type 2 | Base + Module | 4 | 480VAC | 20 kA | 50 kA | 200 kA | 1.5 kV | - | -40°C ~ 85°C | - | DIN Rail | CE, cULus, VDE |
Surge Protection Devices (SPDs) FAQ
Common questions about selecting, comparing and sourcing Surge Protection Devices (SPDs) components through Winsun (HK) Electronics.
What should I check when selecting Surge Protection Devices (SPDs) components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Surge Protection Devices (SPDs) part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Surge Protection Devices (SPDs) parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Surge Protection Devices (SPDs) components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.