Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Contactors (Electromechanical)

Use the filters and product table below to compare Contactors (Electromechanical) components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Features Termination Style Operating Temperature Must Operate Voltage Must Release Voltage
LC1DT60A3E7 Schneider Electric

LC1DT60A3E7

TESYS 4P EVLK CTR 60A AC1 115VAC

Schneider Electric

3,547 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48VAC 4PST-NO (4 Form A) 60 A 690VAC, 300VDC - Max Auxiliary Contacts Spring Terminal -40°C ~ 70°C 38.4 VAC 14.4 VAC
LC1DT60AK7 Schneider Electric

LC1DT60AK7

TESYS 4P EVERLINK CTR 60A AC1 10

Schneider Electric

3,438 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 100VAC 4PST-NO (4 Form A) 60 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 80 VAC 30 VAC
LC1DT60AM7 Schneider Electric

LC1DT60AM7

TESYS 4P EVERLINK CTR 60A AC1 22

Schneider Electric

1,552 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 220VAC 4PST-NO (4 Form A) 60 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 176 VAC 66 VAC
LC1DT60AG7 Schneider Electric

LC1DT60AG7

TESYS 4P EVLK CONTACTOR 60A AC1

Schneider Electric

4,446 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 120VAC 4PST-NO (4 Form A) 60 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 102 VAC 36 VAC
LC1DT60AFE7 Schneider Electric

LC1DT60AFE7

TESYS 4P EVLK CONTACTOR 60A AC1

Schneider Electric

4,576 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 115VAC 4PST-NO (4 Form A) 60 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 92 VAC 34.5 VAC
LC1DT60AW7 Schneider Electric

LC1DT60AW7

TESYS 4P EVERLINK CTR 60A AC1 27

Schneider Electric

4,541 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 277VAC 4PST-NO (4 Form A) 60 A 690VAC, 300VDC - Max Auxiliary Contacts Screw Terminal -40°C ~ 70°C 235.45 VAC 83.1 VAC
LC1D40G6 Schneider Electric

LC1D40G6

CONTACTOR TESYS DECA 40A 3P 120V

Schneider Electric

4,339 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 120VAC 3PST-NO (3 Form A) 40 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 70°C 102 VAC 36 VAC
LC1D40F7 Schneider Electric

LC1D40F7

3P OLD CONT 22KW 1NO 1NC 110VAC

Schneider Electric

1,640 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 110VAC 3PST-NO (3 Form A) 40 A 690VAC - Max Auxiliary Contacts Screw Terminal - 88 VAC 33 VAC
LC1D40M7 Schneider Electric

LC1D40M7

3P OLD CONT 22KW 1NO 1NC 220VAC

Schneider Electric

2,183 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 220VAC 3PST-NO (3 Form A) 40 A 690VAC - Max Auxiliary Contacts Screw Terminal - 176 VAC 66 VAC
LC1D40T6 Schneider Electric

LC1D40T6

CONTACTOR TESYS DECA 40A 3P 480V

Schneider Electric

4,995 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 480VAC 3PST-NO (3 Form A) 40 A 690VAC - Max Auxiliary Contacts Screw Terminal -5°C ~ 70°C 408 VAC 144 VAC
Total 1819 Record«Prev1... 96979899100101102103...182Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Contactors (Electromechanical)?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Contactors (Electromechanical) FAQ

Common questions about filtering, comparing and sourcing Contactors (Electromechanical) components.

How can I narrow the Contactors (Electromechanical) selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Contactors (Electromechanical) part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.