Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
FILTERED PRODUCT SELECTION

Contactors (Electromechanical)

Use the filters and product table below to compare Contactors (Electromechanical) components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.

If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.

Parametric Selection Filter options by technical parameters
Stock & Datasheets Review availability and technical references
RFQ & BOM Support Send your target MPN, quantity or BOM
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Mounting Type Coil Voltage Contact Form Contact Rating (Current) Switching Voltage Features Termination Style Operating Temperature Must Operate Voltage Must Release Voltage
LC1D40A6LE7 Schneider Electric

LC1D40A6LE7

TESYS 3P EVLK CTR40A18,5KWAC3 20

Schneider Electric

4,219 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 208VAC 3PST-NO (3 Form A) 40 A 690VAC, 300VDC - Max Auxiliary Contacts Box Lug -40°C ~ 70°C 176.8 VAC 62.4 VAC
LC1D40A6P7 Schneider Electric

LC1D40A6P7

TESYS 3P EVLK CTR40A18,5KWAC3 23

Schneider Electric

2,925 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 230VAC 3PST-NO (3 Form A) 40 A 690VAC, 300VDC - Max Auxiliary Contacts Box Lug -40°C ~ 70°C 195.5 VAC 69 VAC
LC1D40A6BBE Schneider Electric

LC1D40A6BBE

TESYS CONT 3P 40A AC3 NO+NC 24V

Schneider Electric

2,239 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24VDC 3PST-NO (3 Form A) 40 A 690VAC - Max Auxiliary Contacts Box Lug -40°C ~ 70°C 19.2 VDC 2.4 VDC
LC1D40A6KUE Schneider Electric

LC1D40A6KUE

TESYSCTR3P40A AC3NO+NC100-250V A

Schneider Electric

4,661 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 100 ~ 250VAC/DC 3PST-NO (3 Form A) 40 A 690VAC - Max Auxiliary Contacts Box Lug -40°C ~ 70°C - -
LC1D40A6BNE Schneider Electric

LC1D40A6BNE

TESYS CTR 3P40A AC3NO+NC24-60V A

Schneider Electric

3,587 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 24 ~ 60VAC/DC 3PST-NO (3 Form A) 40 A 690VAC - Max Auxiliary Contacts Box Lug -40°C ~ 70°C - -
LC1D40A6EHE Schneider Electric

LC1D40A6EHE

TESYSCTR3P40A AC3 NO+NC48-130V A

Schneider Electric

2,951 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 48 ~ 130VAC/DC 3PST-NO (3 Form A) 40 A 690VAC - Max Auxiliary Contacts Box Lug -40°C ~ 70°C - -
T02CN13T7 Schneider Electric

T02CN13T7

CONTACTOR TESYS NEMA SZ1 3P 480V

Schneider Electric

3,169 -
Datasheet TeSys Box Active Chassis Mount 480VAC 3PST-NO (3 Form A) 27 A 600VAC - Max Auxiliary Contacts Screw Terminal - - -
T02CN13U7 Schneider Electric

T02CN13U7

CONTACTOR TESYS NEMA SZ1 3P 240V

Schneider Electric

1,017 -
Datasheet TeSys Box Active Chassis Mount 240VAC 3PST-NO (3 Form A) 27 A 600VAC - Max Auxiliary Contacts Screw Terminal - - -
T02CN13B7 Schneider Electric

T02CN13B7

CONTACTOR TESYS NEMA SZ1 3P 24VA

Schneider Electric

2,579 -
Datasheet TeSys Box Active Chassis Mount 24VAC 3PST-NO (3 Form A) 27 A 600VAC - Max Auxiliary Contacts Screw Terminal - - -
LC1D40A6U7 Schneider Electric

LC1D40A6U7

TESYS 3P EVLK CTR40A18,5KWAC3 24

Schneider Electric

1,914 -
Datasheet TeSys Box Active Chassis Mount, DIN Rail 240VAC 3PST-NO (3 Form A) 40 A 690VAC, 300VDC - Max Auxiliary Contacts Box Lug -40°C ~ 70°C 192 VAC 72 VAC
Total 1819 Record«Prev1... 949596979899100101...182Next»
WINSUN SOURCING SUPPORT

Need Help Sourcing Contactors (Electromechanical)?

Send the target part number, manufacturer, specifications and quantity. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and alternative-part options when appropriate.

Availability and lead-time support BOM, shortage and alternative sourcing
FREQUENTLY ASKED QUESTIONS

Contactors (Electromechanical) FAQ

Common questions about filtering, comparing and sourcing Contactors (Electromechanical) components.

How can I narrow the Contactors (Electromechanical) selection?

Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.

Should I confirm the datasheet before selecting a part?

Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.

Can Winsun (HK) Electronics help source a specific Contactors (Electromechanical) part number?

Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.

Do you support BOM, shortage or alternative-part requirements?

Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.