| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
HAR 1000-STRANSDUCER |
1,051 | - |
|
Datasheet | HAR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1000A | 1 | Analog Voltage | - | DC ~ 10kHz | ±0.5% | ±0.5% | 15V | 5µs | 20mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HAXC 1500-STRANSDUCER |
4,503 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
CT 0.1-TPSENSOR CURRENT FLUX 100MA AC/DC |
2,362 | - |
|
Datasheet | CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 100mA | 1 | Ratiometric, Voltage | - | DC ~ 7kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CT 0.2-TPSENSOR CURRENT FLUX 200MA AC/DC |
1,303 | - |
|
Datasheet | CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 200mA | 1 | Ratiometric, Voltage | - | DC ~ 11kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
CT 0.4-TPSENSOR CURRENT FLUX 400MA AC/DC |
2,430 | - |
|
Datasheet | CT | Module | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 400mA | 1 | Ratiometric, Voltage | - | DC ~ 18kHz | ±0.5% | ±1% | ±15V | 60ms | 45mA | -20°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
HAX 1500-S/SP20TRANSDUCER |
3,239 | - |
|
Datasheet | HAX | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 1500A | 1 | Analog Voltage | - | DC ~ 50kHz | ±1% | ±1% | ±15V | 5µs | 20mA | -25°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SPA0TRANSDUCER |
3,906 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±11.4V ~ 21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 510-S/SPA4TRANSDUCER |
4,814 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 310-S/SP20TRANSDUCER |
3,353 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 300A | 1 | Current | 0.5mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±21V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
AP 400 B420LTRANSDUCER |
1,324 | - |
|
Datasheet | AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 200A, 300A, 400A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
AP 100 B420LTRANSDUCER |
3,559 | - |
|
Datasheet | AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 50A, 75A, 100A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | - | Chassis Mount | - |
|
AP 200 B420LTRANSDUCER |
4,826 | - |
|
Datasheet | AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 100A, 150A, 200A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
AP 50 B420LTRANSDUCER |
4,451 | - |
|
Datasheet | AP | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 10A, 25A, 50A (Selectable) | 1 | Current | - | 30Hz ~ 2kHz | ±0.5% | ±1% | 12V ~ 24V | 150ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
ART-B22-D125/SP25CURR SENSE XFMR FLEXIBLE COIL |
2,780 | - |
|
Datasheet | ART | Module | Bulk | Active | AC | Rogowski Coil | 2000A | 1 | Voltage | 0.0225mV/A | 420kHz | - | - | - | - | - | -40°C ~ 80°C | - | - | - | Chassis Mount | - |
|
HAL 750-S/SP1TRANSDUCER |
3,548 | - |
|
Datasheet | - | - | Bulk | Not For New Designs | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 210-S/SP5TRANSDUCER |
4,398 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 100A | 1 | Current | 1mA/A | DC ~ 100kHz | ±0.05% | ±0.2% | ±15.75V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
|
20310500101SENSOR CURRENT HALL 500A AC |
1,040 | - |
|
Datasheet | - | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.6% | 15V ~ 24V | 1µs | 24mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
|
20310200102SENSOR CURRENT HALL 200A AC |
2,346 | - |
|
Datasheet | - | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Hall Effect, Closed Loop | 200A | 1 | Ratiometric, Voltage | - | 100kHz | ±0.1% | ±0.8% | 12V ~ 15V | 1µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Panel Mount | - |
|
LA 305-S/SP5SENSORS |
1,537 | - |
|
Datasheet | LA | Module, Single Pass Through | Bulk | Not For New Designs | AC/DC | Hall Effect, Closed Loop | 300A | 1 | Current | - | DC ~ 100kHz | ±1% | ±0.8% | ±12V ~ 15V | 500ns | - | -10°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 1010-S/SP16TRANSDUCER |
3,647 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Current Sensors FAQ
Common questions about selecting, comparing and sourcing Current Sensors components through Winsun (HK) Electronics.
What should I check when selecting Current Sensors components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Current Sensors part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Current Sensors parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Current Sensors components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.