Current Sensors
Browse available Current Sensors part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
LTC 200-STRANSDUCER |
4,627 | - |
|
Datasheet | LTC | Module | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 200A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.5% | 15V ~ 24V | 1µs | 35mA | -40°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 306-S/SP7TRANSDUCER |
3,194 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 300A | 1 | - | - | DC ~ 100kHz | ±0.1% | ±0.4% | ±15V | 1µs | 20mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
HAX 1500-S/SP18TRANSDUCER |
1,091 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAXC 880-S/SP3TRANSDUCER |
2,870 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20310300301CURRENT SENSOR 300A SMALL |
2,080 | - |
|
Datasheet | * | - | Bulk | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
HAX 1000-S/SP18TRANSDUCER |
4,791 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
LF 1010-S/SP31TRANSDUCER |
4,713 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
ART-B22-D300/SP4CURR SENSE XFMR FLEXIBLE COIL |
4,193 | - |
|
Datasheet | ART | Module | Bulk | Active | AC | Rogowski Coil | 1000A | 1 | - | - | 50Hz/60Hz | - | ±0.5% | - | - | - | -40°C ~ 80°C | - | - | Unidirectional | Chassis Mount | - |
|
APR 200 B420LTRANSDUCER |
1,827 | - |
|
Datasheet | APR | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 100A, 150A, 200A (Selectable) | 1 | Current | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 12V ~ 24V | 400ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
APR 100 B420LTRANSDUCER |
3,556 | - |
|
Datasheet | APR | Module, Single Pass Through | Bulk | Active | AC | Current Transducer | 50A, 75A, 100A (Selectable) | 1 | Current | - | 30Hz ~ 6kHz | ±0.5% | ±1% | 12V ~ 24V | 400ms | - | -20°C ~ 60°C | - | - | Unidirectional | Chassis Mount | - |
|
LF 1010-S/SP25TRANSDUCER |
3,300 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 1000A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.15% | ±0.4% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 510-S/SPA0TRANSDUCER |
4,831 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Closed Loop | 500A | 1 | Current | 0.2mA/A | DC ~ 200kHz | ±0.1% | ±0.6% | ±14.25V ~ 25.2V | 500ns | - | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 510-S/SPA2TRANSDUCER |
1,255 | - |
|
Datasheet | LF | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Closed Loop | 500A | 1 | Current | 0.25mA/A | 200kHz | ±0.1% | ±0.6% | 14.25V ~ 25.2V | 500ns | 49mA | -40°C ~ 85°C | - | - | Bidirectional | Chassis Mount | - |
|
20320100101CURRENT SENSOR HAN OPEN LOOP 100 |
2,782 | - |
|
Datasheet | - | - | Bulk | Obsolete | AC/DC | Current Sensor | 100A | - | - | - | DC ~ 50kHz | - | - | - | - | - | -25°C ~ 85°C | - | - | - | Chassis Mount | - |
|
20320300101CURRENT SENSOR HAN OPEN LOOP 300 |
1,146 | - |
|
Datasheet | - | - | Bulk | Obsolete | AC/DC | Current Sensor | 300A | - | - | - | DC ~ 50kHz | - | - | - | - | - | -25°C ~ 85°C | - | - | - | Chassis Mount | - |
|
HOP 200-SBTRANSDUCER |
4,383 | - |
|
Datasheet | HOP | Module | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Analog Voltage | - | DC ~ 8kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HTR 50-SBTRANSDUCER |
1,479 | - |
|
Datasheet | HTR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Analog Voltage | - | DC ~ 10kHz | ±1% | ±2% | 12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HTR 200-SBTRANSDUCER |
1,245 | - |
|
Datasheet | HTR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 200A | 1 | Analog Voltage | - | DC ~ 10kHz | ±1% | ±2% | ±12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
HTR 100-SBTRANSDUCER |
4,790 | - |
|
Datasheet | HTR | Module, Single Pass Through | Bulk | Active | AC/DC | Hall Effect, Open Loop | 100A | 1 | Analog Voltage | - | DC ~ 10kHz | ±1% | ±2% | 12V ~ 15V | 10µs | 20mA | -10°C ~ 70°C | - | - | Bidirectional | Chassis Mount | - |
|
LF 306-S/SP5TRANSDUCER |
3,214 | - |
|
Datasheet | - | - | Bulk | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Current Sensors FAQ
Common questions about selecting, comparing and sourcing Current Sensors components through Winsun (HK) Electronics.
What should I check when selecting Current Sensors components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Current Sensors part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Current Sensors parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Current Sensors components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.