Current Sensors
Browse available Current Sensors part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
CQ330BSENSOR CURRENT HALL 21A AC/DC |
1,898 | - |
|
Datasheet | CQ | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 21A | 1 | Ratiometric, Voltage | 196mV/A | 1MHz | ±0.6% | ±0.5% | 4.5V ~ 5.5V | 0.5µs | 11mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
CQ320BCORELESS CURENT SENSOR / 20A W/S |
2,079 | - |
|
Datasheet | - | 24-LSSOP (0.220", 5.60mm Width), 10 Leads | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 20.9A | 1 | Ratiometric, Voltage | 120mV/A | - | - | ±1.3% | 3.3V | 0.5µs | 6.2mA | -40°C ~ 90°C | - | - | Bidirectional | Surface Mount | 24-VSOP |
|
MLX91210KDC-CAS-101-SPPLUG & POWER CURRENT SENSOR IC I |
3,702 | - |
|
Datasheet | - | 8-SOIC (0.154", 3.90mm Width) | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 25A | - | Ratiometric, Voltage | 80mV/A | DC ~ 100kHz | ±0.5% | - | 4.5V ~ 5.5V | 5µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
MLX91210KDC-CAS-102-SPPLUG & POWER CURRENT SENSOR IC I |
3,273 | - |
|
Datasheet | - | 8-SOIC (0.154", 3.90mm Width) | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | - | Ratiometric, Voltage | 40mV/A | DC ~ 100kHz | ±0.5% | - | 4.5V ~ 5.5V | 5µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 8-SOIC |
|
MLX91210KDF-CAS-101-SPPLUG & POWER CURRENT SENSOR IC I |
4,261 | - |
|
Datasheet | - | 16-SOIC (0.295", 7.50mm Width) | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 25A | - | Ratiometric, Voltage | 80mV/A | DC ~ 100kHz | ±0.5% | - | 4.5V ~ 5.5V | 5µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 16-SOIC |
|
MLX91210KDF-CAS-102-SPPLUG & POWER CURRENT SENSOR IC I |
2,486 | - |
|
Datasheet | - | 16-SOIC (0.295", 7.50mm Width) | Bulk | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | - | Ratiometric, Voltage | 40mV/A | DC ~ 100kHz | ±0.5% | - | 4.5V ~ 5.5V | 5µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 16-SOIC |
|
MLX91210KDF-CAS-101-REPLUG & POWER CURRENT SENSOR IC I |
2,647 | - |
|
Datasheet | - | 16-SOIC (0.295", 7.50mm Width) | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 25A | - | Ratiometric, Voltage | 80mV/A | DC ~ 100kHz | ±0.5% | - | 4.5V ~ 5.5V | 5µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 16-SOIC |
|
MLX91210KDF-CAS-102-REPLUG & POWER CURRENT SENSOR IC I |
4,779 | - |
|
Datasheet | - | 16-SOIC (0.295", 7.50mm Width) | Tape & Reel (TR) | Obsolete | AC/DC | Hall Effect, Open Loop | 50A | - | Ratiometric, Voltage | 40mV/A | DC ~ 100kHz | ±0.5% | - | 4.5V ~ 5.5V | 5µs | 14mA | -40°C ~ 125°C | - | - | Bidirectional | Surface Mount | 16-SOIC |
|
CQ2366SENSOR CURRENT HALL 50A AC/DC |
2,955 | - |
|
Datasheet | - | Module | Tray | Obsolete | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | Through Hole | - |
|
L08P300D15IPVSENSOR |
3,436 | - |
|
Datasheet | - | Module, Single Pass Through | Tray | Active | AC/DC | Hall Effect, Open Loop | 300A | 1 | Ratiometric, Voltage | - | DC ~ 100kHz | ±1% | - | 15V | 5µs | 20mA | -20°C ~ 80°C | - | - | Bidirectional | Through Hole | - |
|
|
ACS770KCB-050B-PFF-TDDR SENSOR CURRENT HALL CB-5 |
3,319 | - |
|
Datasheet | ACS770 | 5-CB Formed Leads, PFF | Tube | Active | AC/DC | Hall Effect, Open Loop | 50A | 1 | Ratiometric, Voltage | - | DC ~ 120kHz | ±1% | ±0.6% | 5V | 4.6µs | 15mA | -40°C ~ 125°C | - | - | Bidirectional | Through Hole | 5-CB Module |
|
CSNX1000M-101CURRENT SENSOR |
1,285 | - |
|
Datasheet | CSN | 8-DIP Module | Bulk | Obsolete | AC/DC | Magnetoresistive, Open Loop | 8A, 12A, 25A (Selectable) | 3 | Ratiometric, Current | - | DC ~ 200kHz | ±0.1% | ±0.24% | 4.75V ~ 5.25V | 0.2µs | 12mA | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
20310200202CURRENT SENSOR 200A WITH CLAMP T |
3,467 | - |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20310300201CURRENT SENSOR 300A WITH CLAMP T |
4,483 | - |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20310500201CURRENT SENSOR 500A WITH CLAMP T |
3,012 | - |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20310508201CURRENT SENSOR RAILWAY 500A WITH |
4,611 | - |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20310509201CURRENT SENSOR RAILWAY 500A WITH |
1,022 | - |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20311000201CURRENT SENSOR 1000A WITH CLAMP |
2,276 | - |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20311008201CURRENT SENSOR RAILWAY 1000A WIT |
3,316 | - |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
20311009201CURRENT SENSOR RAILWAY 1000A WIT |
4,750 | - |
|
Datasheet | * | - | Bulk | Discontinued at Digi-Key | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
Current Sensors FAQ
Common questions about selecting, comparing and sourcing Current Sensors components through Winsun (HK) Electronics.
What should I check when selecting Current Sensors components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Current Sensors part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Current Sensors parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Current Sensors components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.