Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
EXPLORE COMPONENTS

Current Sensors

Browse available Current Sensors part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.

For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.

Compare Part Numbers Review available models and manufacturers
Datasheets & Specifications Access technical references quickly
RFQ & BOM Support Send quantities for sourcing and quotation
Photo Mfr. Part # Availability Price Quantity Datasheet Series Package/Case Packaging Product Status For Measuring Sensor Type Current - Sensing Number of Channels Output Sensitivity Frequency Linearity Accuracy Voltage - Supply Response Time Current - Supply (Max) Operating Temperature Grade Qualification Polarization Mounting Type Supplier Device Package
SCT-0750-200 Magnelab, Inc.

SCT-0750-200

0.75" SPLIT-CORE CT 200A:333MV

Magnelab, Inc.

4,896 -
Datasheet SCT-0750 Module, Single Pass Through Bag Active AC Current Sensor 200A 1 Ratiometric, Voltage - 30Hz ~ 1kHz ±1% ±1% - - - -20°C ~ 75°C - - Unidirectional Free Hanging -
S6XM50A1000VM Aim Dynamics

S6XM50A1000VM

POWER METER / CT RS485 MODBUS

Aim Dynamics

4,805 -
Datasheet - Module, Single Pass Through Bag Active AC/DC Current Sensor 50A 1 - - DC, 1Hz ~ 400Hz - ±0.5% 9V ~ 30V - - -15°C ~ 65°C - - Bidirectional DIN Rail, Panel -
RCT-1800-1000 Magnelab, Inc.

RCT-1800-1000

18" COIL 1000A:333MVAC

Magnelab, Inc.

4,337 -
Datasheet RCT Module Bag Active AC Current Sensor 1000A 1 Ratiometric, Voltage - - - ±1% 12V ~ 30V - - -20°C ~ 105°C - - - Chassis Mount -
SCT-0400-020 Magnelab, Inc.

SCT-0400-020

0.4" SPLIT-CORE CT 20A:333MV

Magnelab, Inc.

2,272 -
Datasheet SCT-0400 Module, Single Pass Through Bag Active AC Current Sensor 20A 1 Ratiometric, Voltage - 50Hz ~ 1kHz ±1% ±1% - - - -20°C ~ 75°C - - Unidirectional Free Hanging -
VCS10 Vektrex

VCS10

ISOLATED CURRENT SENSOR

Vektrex

1,348 -
Datasheet VCS Module Box Active AC/DC Hall Effect 10A - Ratiometric, Voltage - DC ~ 650kHz - 0.5% 9V ~ 18V - - - - - - Chassis Mount -
ACS37612LLUALU-015U5 Allegro MicroSystems

ACS37612LLUALU-015U5

SENSOR CUR HALL 26.5MT 8TSSOP

Allegro MicroSystems

2,926 -
Datasheet - 8-TSSOP (0.173", 4.40mm Width) Tape & Reel (TR) Discontinued at Digi-Key AC/DC Hall Effect 26.5mT 1 Ratiometric, Voltage 15mV/g DC ~ 120kHz ±1% ±2% 4.5V ~ 5.5V - 16mA -40°C ~ 150°C Automotive AEC-Q100 Unidirectional Surface Mount 8-TSSOP
TLI4970D050T4 Infineon Technologies

TLI4970D050T4

MAGNETIC SWITCH CURRENT SENSOR

Infineon Technologies

1,587 -
Datasheet - 8-PowerTDFN Bulk Active AC/DC Hall Effect, Differential 50A 1 SPI - DC ~ 18kHz ±2% ±0.05% 3.1V ~ 3.5V - 20mA -40°C ~ 85°C - - Unidirectional Surface Mount -
TLI4970-D050T5XUMA1 Infineon Technologies

TLI4970-D050T5XUMA1

MAGNETIC SWITCH CURRENT SENSOR

Infineon Technologies

2,157 -
Datasheet - 8-TDFN Bulk Active AC/DC Hall Effect, Differential 50A 1 SPI - DC ~ 18kHz ±3.5% ±0.05% 3.1V ~ 3.5V - 20mA -40°C ~ 85°C - - Unidirectional Surface Mount -
IT205-S/SP1 LEM USA Inc.

IT205-S/SP1

CURRENT TRANSDUCER 200A

LEM USA Inc.

1,022 -
Datasheet IT Module, Single Pass Through Bulk Obsolete AC/DC Flux Gate, Closed Loop 200A 1 - - 1MHz ±0.0011% - ±14.25V ~ 15.75V 1µs 78mA -40°C ~ 85°C - - Unidirectional Chassis Mount -
LTS 6-NP BLISTER 3P LEM USA Inc.

LTS 6-NP BLISTER 3P

CURRENT TRANSDUCER 6A

LEM USA Inc.

1,643 -
Datasheet LTS Module, Single Pass Through Tray Obsolete AC/DC Hall Effect, Closed Loop 6A 1 Ratiometric, Voltage 104.16mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTSR 25-NP/SP1 LEM USA Inc.

LTSR 25-NP/SP1

CURRENT TRANSDUCER 25A

LEM USA Inc.

4,147 -
Datasheet LTSR Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 25A 1 Ratiometric, Voltage 25mV/A DC ~ 100kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 6-NP/SP2 LEM USA Inc.

LTS 6-NP/SP2

CURRENT TRANSDUCER 6A

LEM USA Inc.

2,807 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 6A 1 Ratiometric, Voltage 104.16mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 15-NP/SP5 LEM USA Inc.

LTS 15-NP/SP5

CURRENT TRANSDUCER 14A

LEM USA Inc.

4,593 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 15A 1 Ratiometric, Voltage 41.6mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 25-NP/SP6 LEM USA Inc.

LTS 25-NP/SP6

CURRENT TRANSDUCER 25A

LEM USA Inc.

1,547 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 25A 1 Ratiometric, Voltage 25mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 6-NP/SP3 LEM USA Inc.

LTS 6-NP/SP3

CURRENT TRANSDUCER 6A

LEM USA Inc.

4,958 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 6A 1 Ratiometric, Voltage 104.16mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 6-NP/SP14 LEM USA Inc.

LTS 6-NP/SP14

CURRENT TRANSDUCER 6A

LEM USA Inc.

3,146 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 6A 1 Ratiometric, Voltage 104.16mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 15-NP/SP1 LEM USA Inc.

LTS 15-NP/SP1

CURRENT TRANSDUCER 14A

LEM USA Inc.

3,859 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 15A 1 Ratiometric, Voltage 41.6mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 25-NP/SP4 LEM USA Inc.

LTS 25-NP/SP4

CURRENT TRANSDUCER 25A

LEM USA Inc.

4,856 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 25A 1 Ratiometric, Voltage 25mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 15-NP/SP7 LEM USA Inc.

LTS 15-NP/SP7

CURRENT TRANSDUCER 14A

LEM USA Inc.

3,705 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 15A 1 Ratiometric, Voltage 41.6mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
LTS 25-NP/SP7 LEM USA Inc.

LTS 25-NP/SP7

CURRENT TRANSDUCER 25A

LEM USA Inc.

2,956 -
Datasheet LTS Module, Single Pass Through Tube Obsolete AC/DC Hall Effect, Closed Loop 25A 1 Ratiometric, Voltage 25mV/A DC ~ 200kHz ±0.1% ±0.2% 4.75V ~ 5.25V 400ns 28mA (Typ) -40°C ~ 85°C - - Bidirectional Through Hole -
Total 5184 Record«Prev1... 249250251252253254255256...260Next»
WINSUN SOURCING SUPPORT

Need Current Sensors Sourcing Support?

Send the manufacturer, part number, quantity and target delivery requirement. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and hard-to-find or obsolete components.

Global component sourcing support BOM, shortage and EOL support
FREQUENTLY ASKED QUESTIONS

Current Sensors FAQ

Common questions about selecting, comparing and sourcing Current Sensors components through Winsun (HK) Electronics.

What should I check when selecting Current Sensors components?

Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.

Can Winsun help source specific Current Sensors part numbers?

Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.

Do you support shortage, obsolete or hard-to-find Current Sensors parts?

Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.

How do I request a quote for Current Sensors components?

Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.