| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package/Case | Packaging | Product Status | For Measuring | Sensor Type | Current - Sensing | Number of Channels | Output | Sensitivity | Frequency | Linearity | Accuracy | Voltage - Supply | Response Time | Current - Supply (Max) | Operating Temperature | Grade | Qualification | Polarization | Mounting Type | Supplier Device Package |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
SCT-0750-2000.75" SPLIT-CORE CT 200A:333MV |
4,896 | - |
|
Datasheet | SCT-0750 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 200A | 1 | Ratiometric, Voltage | - | 30Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
S6XM50A1000VMPOWER METER / CT RS485 MODBUS |
4,805 | - |
|
Datasheet | - | Module, Single Pass Through | Bag | Active | AC/DC | Current Sensor | 50A | 1 | - | - | DC, 1Hz ~ 400Hz | - | ±0.5% | 9V ~ 30V | - | - | -15°C ~ 65°C | - | - | Bidirectional | DIN Rail, Panel | - |
|
RCT-1800-100018" COIL 1000A:333MVAC |
4,337 | - |
|
Datasheet | RCT | Module | Bag | Active | AC | Current Sensor | 1000A | 1 | Ratiometric, Voltage | - | - | - | ±1% | 12V ~ 30V | - | - | -20°C ~ 105°C | - | - | - | Chassis Mount | - |
|
SCT-0400-0200.4" SPLIT-CORE CT 20A:333MV |
2,272 | - |
|
Datasheet | SCT-0400 | Module, Single Pass Through | Bag | Active | AC | Current Sensor | 20A | 1 | Ratiometric, Voltage | - | 50Hz ~ 1kHz | ±1% | ±1% | - | - | - | -20°C ~ 75°C | - | - | Unidirectional | Free Hanging | - |
|
VCS10ISOLATED CURRENT SENSOR |
1,348 | - |
|
Datasheet | VCS | Module | Box | Active | AC/DC | Hall Effect | 10A | - | Ratiometric, Voltage | - | DC ~ 650kHz | - | 0.5% | 9V ~ 18V | - | - | - | - | - | - | Chassis Mount | - |
|
ACS37612LLUALU-015U5SENSOR CUR HALL 26.5MT 8TSSOP |
2,926 | - |
|
Datasheet | - | 8-TSSOP (0.173", 4.40mm Width) | Tape & Reel (TR) | Discontinued at Digi-Key | AC/DC | Hall Effect | 26.5mT | 1 | Ratiometric, Voltage | 15mV/g | DC ~ 120kHz | ±1% | ±2% | 4.5V ~ 5.5V | - | 16mA | -40°C ~ 150°C | Automotive | AEC-Q100 | Unidirectional | Surface Mount | 8-TSSOP |
|
TLI4970D050T4MAGNETIC SWITCH CURRENT SENSOR |
1,587 | - |
|
Datasheet | - | 8-PowerTDFN | Bulk | Active | AC/DC | Hall Effect, Differential | 50A | 1 | SPI | - | DC ~ 18kHz | ±2% | ±0.05% | 3.1V ~ 3.5V | - | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Surface Mount | - |
|
TLI4970-D050T5XUMA1MAGNETIC SWITCH CURRENT SENSOR |
2,157 | - |
|
Datasheet | - | 8-TDFN | Bulk | Active | AC/DC | Hall Effect, Differential | 50A | 1 | SPI | - | DC ~ 18kHz | ±3.5% | ±0.05% | 3.1V ~ 3.5V | - | 20mA | -40°C ~ 85°C | - | - | Unidirectional | Surface Mount | - |
|
IT205-S/SP1CURRENT TRANSDUCER 200A |
1,022 | - |
|
Datasheet | IT | Module, Single Pass Through | Bulk | Obsolete | AC/DC | Flux Gate, Closed Loop | 200A | 1 | - | - | 1MHz | ±0.0011% | - | ±14.25V ~ 15.75V | 1µs | 78mA | -40°C ~ 85°C | - | - | Unidirectional | Chassis Mount | - |
|
LTS 6-NP BLISTER 3PCURRENT TRANSDUCER 6A |
1,643 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tray | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.16mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTSR 25-NP/SP1CURRENT TRANSDUCER 25A |
4,147 | - |
|
Datasheet | LTSR | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | DC ~ 100kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 6-NP/SP2CURRENT TRANSDUCER 6A |
2,807 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.16mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 15-NP/SP5CURRENT TRANSDUCER 14A |
4,593 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.6mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 25-NP/SP6CURRENT TRANSDUCER 25A |
1,547 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 6-NP/SP3CURRENT TRANSDUCER 6A |
4,958 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.16mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 6-NP/SP14CURRENT TRANSDUCER 6A |
3,146 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 6A | 1 | Ratiometric, Voltage | 104.16mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 15-NP/SP1CURRENT TRANSDUCER 14A |
3,859 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.6mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 25-NP/SP4CURRENT TRANSDUCER 25A |
4,856 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 15-NP/SP7CURRENT TRANSDUCER 14A |
3,705 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 15A | 1 | Ratiometric, Voltage | 41.6mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
|
LTS 25-NP/SP7CURRENT TRANSDUCER 25A |
2,956 | - |
|
Datasheet | LTS | Module, Single Pass Through | Tube | Obsolete | AC/DC | Hall Effect, Closed Loop | 25A | 1 | Ratiometric, Voltage | 25mV/A | DC ~ 200kHz | ±0.1% | ±0.2% | 4.75V ~ 5.25V | 400ns | 28mA (Typ) | -40°C ~ 85°C | - | - | Bidirectional | Through Hole | - |
Current Sensors FAQ
Common questions about selecting, comparing and sourcing Current Sensors components through Winsun (HK) Electronics.
What should I check when selecting Current Sensors components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Current Sensors part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Current Sensors parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Current Sensors components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.