Electrical, Specialty Fuses
Browse available Electrical, Specialty Fuses part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
A4J150FUSE,CLASS J,HIGH SPEED,200KA AC |
2,257 | - |
|
Datasheet | A4J | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 150A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 1.614" Dia x 5.748" L (41.00mm x 146.00mm) | - | - |
|
L17T300.VFUSE CRTRDGE 300A 170VDC CYLINDR |
4,934 | - |
|
Datasheet | POWR-GARD® L17T | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 300A | - | 170 VDC | Fast Blow | Telecom | - | - | CE, CSA, UR | - | 100kA | 1.500" Dia x 1.252" L (38.10mm x 31.80mm) | - | - |
|
170M1566DFUSE SQUARE 80A 690VAC RECT |
3,522 | - |
|
Datasheet | - | Rectangular, Blade | Bulk | Active | Requires Holder | Square | 80A | 690 VAC | - | - | Electrical, Industrial | Indicating | - | CE, CSA, UR | - | 200kA | 2.087" L x 0.807" W x 2.047" H (53.00mm x 20.50mm x 52.00mm) | - | - |
|
A70P400-4SC FUSE 700V 400A P BLADE |
1,806 | - |
|
Datasheet | A70P | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 400A | 700 VAC | 650 VDC | Fast Blow | Electrical, Industrial | Indicating | - | UR | - | 100kA | 2.000" Dia x 5.079" L (50.80mm x 129.00mm) | - | - |
|
A6D110R600V 110A RK1 TD FUSE |
4,081 | - |
|
Datasheet | A6D-R | Cartridge, Non-Standard | Box | Active | Requires Holder | Cartridge | 100mA | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 0.811" Dia x 5.000" L (20.60mm x 127.00mm) | - | - |
|
HSJ150600V 150A CLASS J HS FUSE |
2,859 | - |
|
Datasheet | HSJ | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 150A | 600 VAC | 500 VDC | Fast Blow | Electrical, Industrial | - | J | CSA, UL | - | 200kA AC, 100kA DC | 1.614" Dia x 5.748" L (41.00mm x 146.00mm) | - | - |
|
0581500.XFUSE STRIP 500A 48VAC/VDC RECT |
4,637 | - |
|
Datasheet | POWR-GARD® HAZGARD | Rectangular, Blade | Bulk | Active | Bolt Mount | Fuse Strip | 500A | 48 VAC | 48 VDC | Fast Blow | Lift Trucks | - | - | UR | - | 2.5kA | 3.228" L x 1.195" W x 0.683" H (82.00mm x 30.35mm x 17.35mm) | - | - |
|
A2D300R250V 300A RK1 TD FUSE |
1,939 | - |
|
Datasheet | A2D-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 300A | 250 VAC | 250 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 2.087" Dia x 8.622" L (53.00mm x 219.00mm) | - | - |
|
A2D225R250V 225A RK1 TD FUSE |
2,786 | - |
|
Datasheet | A2D-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 225A | 250 VAC | 250 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 2.087" Dia x 8.622" L (53.00mm x 219.00mm) | - | - |
|
0581800.XFUSE STRIP 800A 48VAC/VDC RECT |
3,115 | - |
|
Datasheet | POWR-GARD® HAZGARD | Rectangular, Blade | Bulk | Active | Bolt Mount | Fuse Strip | 800A | 48 VAC | 48 VDC | Fast Blow | Lift Trucks | - | - | UR | - | 2.5kA | 3.228" L x 1.195" W x 0.683" H (82.00mm x 30.35mm x 17.35mm) | - | - |
|
A2D400R250V 400A RK1 TD FUSE |
4,262 | - |
|
Datasheet | A2D-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 400A | 250 VAC | 250 VDC | Slow Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 100kA DC | 2.087" Dia x 8.622" L (53.00mm x 219.00mm) | - | - |
|
M30J12SWITCH.FUS 30A J 1+2 POS. |
1,466 | - |
|
Datasheet | - | - | Box | Active | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
|
TR450RFUSE,TIME DELAY,CLASS RK5,REJECT |
2,218 | - |
|
Datasheet | TR-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 450A | 250 VAC | 160 VDC | Slow Blow | Electrical, Industrial | - | RK5 | CSA, UL | - | 200kA AC, 20kA DC | 2.598" Dia x 10.394" L (66.00mm x 264.00mm) | - | - |
|
A70P300-4SC FUSE 700V 300A P BLADE |
4,913 | - |
|
Datasheet | A70P | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 300A | 700 VAC | 650 VDC | Fast Blow | Electrical, Industrial | Indicating | - | UR | - | 100kA | 2.000" Dia x 5.079" L (50.80mm x 129.00mm) | - | - |
|
A70QS350-4FUSE,HIGH SPEED,NO BLOWN INDICAT |
2,735 | - |
|
Datasheet | A70QS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 350A | 700 VAC | 700 VDC | Fast Blow | Motor Protection | - | - | CSA, UL | - | 200kA AC, 100kA DC | 1.500" Dia x 5.079" L (38.10mm x 129.00mm) | - | - |
|
TR600R250V 600A 10 3/8X2 9/16 T |
4,743 | - |
|
Datasheet | TR-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 600A | 250 VAC | 160 VDC | Slow Blow | Electrical, Industrial | - | RK5 | CSA, UL | - | 200kA AC, 20kA DC | 2.598" Dia x 10.394" L (66.00mm x 264.00mm) | - | - |
|
A2K200RFUSE,FAST ACTING,CLASS RK1,REJEC |
4,063 | - |
|
Datasheet | A2K-R | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 200A | 250 VAC | 250 VDC | Fast Blow | Electrical, Industrial | - | RK1 | CSA, UL | - | 200kA AC, 20kA DC | 1.575" Dia x 7.126" L (40.00mm x 181.00mm) | - | - |
|
|
JLLS400.XFUSE CRTRDGE 400A 600VAC/300VDC |
1,086 | - |
|
Datasheet | POWR-GARD® JLLS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 400A | 600 VAC | 300 VDC | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UL | - | 200kA | 1.594" Dia x 1.720" L (40.50mm x 43.70mm) | - | - |
|
SPFJ080.XFUSE CARTRIDGE 80A 1KVDC CYLINDR |
1,096 | - |
|
Datasheet | POWR-GARD® SPFJ | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 80A | - | 1 kVDC | Fast Blow | Solar (Photovoltaic) | - | J | CE, UL | - | 20kA | 1.500" Dia x 3.012" L (38.10mm x 76.50mm) | - | - |
|
TRS250R600V 250A 11 5/8X2 9/16 T |
4,069 | - |
|
Datasheet | TRS-R | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 250A | 600 VAC | 600 VDC | Slow Blow | Electrical, Industrial | - | RK5 | CSA, UL | - | 200kA AC, 100kA DC | 2.598" Dia x 11.614" L (66.00mm x 295.00mm) | - | - |
Electrical, Specialty Fuses FAQ
Common questions about selecting, comparing and sourcing Electrical, Specialty Fuses components through Winsun (HK) Electronics.
What should I check when selecting Electrical, Specialty Fuses components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Electrical, Specialty Fuses part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Electrical, Specialty Fuses parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Electrical, Specialty Fuses components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.