Electrical, Specialty Fuses
Use the filters and product table below to compare Electrical, Specialty Fuses components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.
If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
BK/GMT-7-1/2AFUSE INDICATING 7.5A 125VAC/60DC |
434 | - |
|
Datasheet | GMT | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 7.5A | 125 VAC | 60 VDC | Fast Blow | Telecom | Indicating | - | UR | - | 300A AC, 450A DC | 0.688" L x 0.127" W x 0.810" H (17.48mm x 3.23mm x 20.57mm) | - | - |
|
BK/GMT-15AFUSE INDICATING 15A 125VAC/60VDC |
548 | - |
|
Datasheet | GMT | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 15A | 125 VAC | 60 VDC | Fast Blow | Telecom | Indicating | - | UR | - | 300A AC, 450A DC | 0.688" L x 0.127" W x 0.810" H (17.48mm x 3.23mm x 20.57mm) | - | - |
|
BK/GMT-10AFUSE INDICATING 10A 125VAC/60VDC |
1,681 | - |
|
Datasheet | GMT | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 10A | 125 VAC | 60 VDC | Fast Blow | Telecom | Indicating | - | UR | - | 300A AC, 450A DC | 0.688" L x 0.127" W x 0.810" H (17.48mm x 3.23mm x 20.57mm) | - | - |
|
BK/GMT-5AFUSE INDICATING 5A 125VAC/60VDC |
1,342 | - |
|
Datasheet | GMT | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 5A | 125 VAC | 60 VDC | Fast Blow | Telecom | Indicating | - | UR | - | 300A AC, 450A DC | 0.688" L x 0.127" W x 0.810" H (17.48mm x 3.23mm x 20.57mm) | - | - |
|
FWA-20A10FFUSE CRTRDGE 20A 150VAC/VDC 5AG |
2,762 | - |
|
Datasheet | FWA | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 20A | 150 VAC | 150 VDC | - | Electrical, Industrial | - | - | CE, UR | - | 100kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
FWC-32A10FFUSE CARTRIDGE 32A 600VAC 5AG |
1,164 | - |
|
Datasheet | FWC | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 32A | 600 VAC | - | - | Electrical, Industrial | - | - | CE, UR | - | 50kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
KTK-R-15FUSE CARTRIDGE 15A 600VAC 5AG |
3,112 | - |
|
Datasheet | Limitron™ KTK-R | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 15A | 600 VAC | - | Fast Blow | Electrical, Industrial | - | CC | CE, CSA, UL | - | 200kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
KTK-R-20FUSE CARTRIDGE 20A 600VAC 5AG |
3,484 | - |
|
Datasheet | Limitron™ KTK-R | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 20A | 600 VAC | - | Fast Blow | Electrical, Industrial | - | CC | CE, CSA, UL | - | 200kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
|
FNQ-30FUSE CARTRIDGE 30A 500VAC 5AG |
3,718 | - |
|
Datasheet | FNQ | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 30A | 500 VAC | - | Slow Blow | Electrical, Industrial | - | - | CE, CSA, UL | - | 10kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
FNQ-R-20FUSE CARTRIDGE 20A 600VAC/300VDC |
1,038 | - |
|
Datasheet | Limitron™ FNQ-R | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 20A | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | - | CC | CE, CSA, UL | - | 200kA AC, 20kA DC | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
Electrical, Specialty Fuses FAQ
Common questions about filtering, comparing and sourcing Electrical, Specialty Fuses components.
How can I narrow the Electrical, Specialty Fuses selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Electrical, Specialty Fuses part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.