Electrical, Specialty Fuses
Use the filters and product table below to compare Electrical, Specialty Fuses components by manufacturer, availability, pricing reference and technical specifications. Review datasheets and key parameters to narrow the selection for your application.
If you already have a target part number, package, rating or quantity, send the requirement to Winsun (HK) Electronics for availability checks, BOM sourcing, shortage support and quotation assistance.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
FWP-80A22FFUSE CARTRIDGE 80A 700VAC/500VDC |
156 | - |
|
Datasheet | FWP | Cartridge, Non-Standard | Bulk | Active | Requires Holder | Cartridge | 80A | 700 VAC | 500 VDC | - | Electrical, Industrial | - | - | CE, UR | - | 200kA AC, 50kA DC | 0.874" Dia x 2.283" L (22.20mm x 58.00mm) | - | - |
|
|
TCF80FUSE RECT 80A 600VAC/300VDC BLAD |
2,733 | - |
|
Datasheet | CUBEFuse™ TCF | Blade Type, Module | Bulk | Active | Requires Holder | Rectangular | 80A | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | Indicating | - | CE, CSA, UL | -40°C ~ 80°C | 300kA AC, 100kA DC | 1.880" L x 0.750" W x 1.270" H (47.75mm x 19.05mm x 32.26mm) | - | - |
|
BK/GMT-2AFUSE INDICATING 2A 125VAC/60VDC |
1,401 | - |
|
Datasheet | GMT | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 2A | 125 VAC | 60 VDC | Fast Blow | Telecom | Indicating | - | UR | - | 300A AC, 450A DC | 0.688" L x 0.127" W x 0.810" H (17.48mm x 3.23mm x 20.57mm) | - | - |
|
BK/GMT-3AFUSE INDICATING 3A 125VAC/60VDC |
638 | - |
|
Datasheet | GMT | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 3A | 125 VAC | 60 VDC | Fast Blow | Telecom | Indicating | - | UR | - | 300A AC, 450A DC | 0.688" L x 0.127" W x 0.810" H (17.48mm x 3.23mm x 20.57mm) | - | - |
|
BK/GMT-1AFUSE INDICATING 1A 125VAC/60VDC |
101 | - |
|
Datasheet | GMT | Alarm Indicator | Bulk | Active | Requires Holder | Indicating Fuse | 1A | 125 VAC | 60 VDC | Fast Blow | Telecom | Indicating | - | UR | - | 300A AC, 450A DC | 0.688" L x 0.127" W x 0.810" H (17.48mm x 3.23mm x 20.57mm) | - | - |
|
FNM-5FUSE CARTRIDGE 5A 250VAC 5AG |
182 | - |
|
Datasheet | FNM | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 5A | 250 VAC | - | Slow Blow | Motor Protection, Transformer Protection | - | - | CE, CSA, UL | - | 200A | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
PV-15A10FFUSE CARTRIDGE 15A 1KVDC 5AG |
4,835 | - |
|
Datasheet | PV | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 15A | - | 1 kVDC | - | Solar (Photovoltaic) | - | - | CCC, CSA, UL | -40°C ~ 90°C | 50kA | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
|
KTK-R-2FUSE CARTRIDGE 2A 600VAC 5AG |
1,126 | - |
|
Datasheet | Limitron™ KTK-R | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 2A | 600 VAC | - | Fast Blow | Electrical, Industrial | - | CC | CE, CSA, UL | - | 200kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
|
PV-1A10FFUSE CARTRIDGE 1A 1KVDC 5AG |
2,643 | - |
|
Datasheet | PV | 5AG, 10mm x 38mm (Midget) | Bulk | Active | Requires Holder | Cartridge | 1A | - | 1 kVDC | - | Solar (Photovoltaic) | - | - | CCC, CSA, UL | -40°C ~ 90°C | 50kA | 0.406" Dia x 1.496" L (10.30mm x 38.00mm) | - | - |
|
KTK-R-30FUSE CRTRDGE 30A 600VAC CYLINDER |
2,099 | - |
|
Datasheet | Limitron™ KTK-R | Cylinder | Bulk | Active | Requires Holder | Cartridge | 30A | 600 VAC | - | Fast Blow | Electrical, Industrial | - | CC | CE, CSA, UL | - | 200kA | 0.406" Dia x 1.500" L (10.30mm x 38.10mm) | - | - |
Electrical, Specialty Fuses FAQ
Common questions about filtering, comparing and sourcing Electrical, Specialty Fuses components.
How can I narrow the Electrical, Specialty Fuses selection?
Use the available manufacturer and technical parameter filters to reduce the product list. Compare the remaining part numbers against your electrical, package and application requirements.
Should I confirm the datasheet before selecting a part?
Yes. Always review the manufacturer datasheet to confirm ratings, package, operating conditions and other technical details before finalizing a component for your design.
Can Winsun (HK) Electronics help source a specific Electrical, Specialty Fuses part number?
Yes. Send the exact manufacturer part number and required quantity for availability, lead-time and quotation support.
Do you support BOM, shortage or alternative-part requirements?
Yes. You can submit a BOM or shortage list for sourcing assistance. Where appropriate, our team can also help review possible alternative-part options.