Gas Sensors
Browse available Gas Sensors part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.
For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature | Voltage - Supply | Current - Supply |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
T3031-2-5K-24-PSENSOR CARBON DIOXIDE 0-10V OUT |
3,991 | - |
|
Datasheet | T3000 | Bulk | Active | Carbon Dioxide (CO2) | - | ±5% | 0 V ~ 10 V | 0°C ~ 50°C | 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC | - |
|
NH3-500-PROBESENSOR AMMONIA RS485 OUTPUT |
1,808 | - |
|
Datasheet | - | Bulk | Active | Ammonia (NH3) | - | ±5% | RS485 | -20°C ~ 55°C | 5V ~ 12V | 1A |
|
COM-21506SENSOR AIR QUALITY I2C OUTPUT |
4,632 | - |
|
Datasheet | - | Bulk | Active | Air Quality | - | ±2% | I2C | 0°C ~ 25°C | 1.7V ~ 3.6V | 7mA |
|
SGX-4H2S-100SENSOR HYDROGEN SULFIDE CUR OUT |
4,000 | - |
|
Datasheet | 4 | Bulk | Active | Hydrogen Sulfide (H2S) | 800 mbar ~ 1200 mbar | - | Current | -30°C ~ 50°C | - | 300µA |
|
SGX-CO-LPSENSOR CARB MONOX CURRENT OUT |
1,499 | - |
|
Datasheet | - | Bulk | Active | Carbon Monoxide (CO) | 800 mbar ~ 1.2 bar | - | Current | -30°C ~ 50°C | - | - |
|
SGX-OX-LPSENSOR OXYGEN CURRENT OUTPUT |
4,349 | - |
|
Datasheet | - | Bulk | Active | Oxygen | 800 mbar ~ 1.2 bar | - | Current | -20°C ~ 50°C | - | - |
|
SGX-4NO2-2ERSENSOR NITROGEN DIOXIDE CUR OUT |
1,177 | - |
|
Datasheet | - | Bulk | Active | Nitrogen Dioxide (NO2) | 800 mbar ~ 1.2 bar | - | Current | -30°C ~ 50°C | - | - |
|
SGX-4H2-1000SENSOR HYDROGEN CURRENT OUTPUT |
2,354 | - |
|
Datasheet | - | Bulk | Active | Hydrogen (H2) | 800 mbar ~ 1.2 bar | - | Current | -30°C ~ 50°C | - | - |
|
INIR4-R32SENSOR AIR QUALITY PWM OUTPUT |
1,246 | - |
|
Datasheet | - | Bulk | Active | Air Quality | 600 mbar ~ 1.2 bar | - | PWM, UART | -20°C ~ 60°C | 3.2V ~ 5.25V | 32mA |
|
SGX-VOXSENSOR OXYGEN CURRENT OUTPUT |
4,022 | - |
|
Datasheet | - | Bulk | Active | Oxygen | 800 mbar ~ 1200 mbar | - | Current | -30°C ~ 50°C | - | 10mA |
|
USEQGCDAC8N100SENSOR CARB MONOX VOLTAGE OUT |
4,994 | - |
|
Datasheet | QGC | Bulk | Active | Carbon Monoxide (CO) | - | - | Voltage | -40°C ~ 85°C | 2.7V ~ 8V | - |
|
SGX-4OX-ROHSSENSOR OXYGEN CURRENT OUTPUT |
4,735 | - |
|
Datasheet | 4 | Bulk | Active | Oxygen | 800 mbar ~ 1200 mbar | - | Current | -40°C ~ 60°C | - | 10µA |
|
INIR4-R290SENSOR AIR QUALITY PWM OUTPUT |
3,853 | - |
|
Datasheet | - | Bulk | Active | Air Quality | 600 mbar ~ 1.2 bar | - | PWM, UART | -20°C ~ 60°C | 3.2V ~ 5.25V | 32mA |
|
972-100SENSOR CARBON MONOXIDE UART OUT |
3,177 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Carbon Monoxide (CO) | 0 mbar ~ 10 bar | ±15% | UART | -20°C ~ 40°C | 2.6V ~ 3.6V | 10mA |
|
972-200SENSOR ALCOHOL UART OUTPUT |
4,094 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Alcohol (C2H6O) | 0 mbar ~ 15 bar | ±15% | UART | -20°C ~ 40°C | 2.6V ~ 3.6V | 10mA |
|
972-300SENSOR HYDROGEN SULFIDE UART OUT |
1,931 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Hydrogen Sulfide (H2S) | 0 mbar ~ 250 mbar | ±15% | UART | -20°C ~ 40°C | 2.6V ~ 3.6V | 10mA |
|
972-110SENSOR CARBON MONOXIDE UART OUT |
1,865 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Carbon Monoxide (CO) | 0 mbar ~ 500 mbar | ±15% | UART | -20°C ~ 40°C | 2.6V ~ 3.6V | 10mA |
|
972-800SENSOR AIR QUALITY UART OUTPUT |
2,361 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Air Quality | 0 mbar ~ 2.5 bar | ±15% | UART | -20°C ~ 40°C | 2.6V ~ 3.6V | 10mA |
|
972-900SENSOR AIR QUALITY UART OUTPUT |
1,937 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Air Quality | 0 mbar ~ 500 mbar | ±15% | UART | -20°C ~ 40°C | 2.6V ~ 3.6V | 10mA |
|
972-001SENSOR HYDROGEN UART OUTPUT |
4,402 | - |
|
Datasheet | DGS2 970 | Bulk | Active | Hydrogen (H2) | 0 mbar ~ 2.5 bar | ±15% | UART | -20°C ~ 40°C | 2.6V ~ 3.6V | 10mA |
Gas Sensors FAQ
Common questions about selecting, comparing and sourcing Gas Sensors components through Winsun (HK) Electronics.
What should I check when selecting Gas Sensors components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Gas Sensors part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Gas Sensors parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Gas Sensors components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.