| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Type | Oxygen Range | Accuracy | Output | Operating Temperature | Voltage - Supply | Current - Supply |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
T5100-E-VSENSOR CARBON DIOXIDE |
3,840 | - |
|
Datasheet | T5100 | Bulk | Active | Carbon Dioxide (CO2) | - | ±3% | 0V ~ 5V, 0V ~ 10V | 0°C ~ 50°C | 18VAC ~ 30VAC, 18VDC ~ 42VDC | - |
|
T5100-E-GN-VSENSOR CARBON DIOXIDE |
3,015 | - |
|
Datasheet | T5100 | Bulk | Active | Carbon Dioxide (CO2) | - | ±3% | 0V ~ 5V, 0V ~ 10V | 0°C ~ 50°C | 18VAC ~ 30VAC, 18VDC ~ 42VDC | - |
|
T5100-GN-VSENSOR CARBON DIOXIDE |
2,555 | - |
|
Datasheet | T5100 | Bulk | Active | Carbon Dioxide (CO2) | - | ±3% | 0V ~ 5V, 0V ~ 10V | 0°C ~ 50°C | 18VAC ~ 30VAC, 18VDC ~ 42VDC | - |
|
|
IR11EJSENSOR CARBON DIOXIDE VOLT OUT |
2,732 | - |
|
Datasheet | IR1 | Bulk | Active | Carbon Dioxide (CO2) | - | - | Voltage | -20°C ~ 55°C | 3V ~ 5V | 35mA |
|
|
IR12EMSENSOR HYDROCARBON VOLTAGE OUT |
4,111 | - |
|
Datasheet | IR1 | Bulk | Active | Hydrocarbons, Methane | - | - | Voltage | -20°C ~ 55°C | 3V ~ 5V | 35mA |
|
|
IR12GM_1SENSOR HYDROCARBON VOLTAGE OUT |
2,118 | - |
|
Datasheet | IR1 | Bulk | Active | Hydrocarbons, Methane | - | - | Voltage | -20°C ~ 55°C | 3V ~ 5V | - |
|
INIR2-RF-R290SENSOR INTEG INFRARED |
1,293 | - |
|
Datasheet | * | Bulk | Active | - | - | - | - | - | - | - |
|
|
VQ622T/1SENSOR HYDROCARBONS VOLTAGE OUT |
2,751 | - |
|
Datasheet | VQ600 | Bulk | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 175mA |
|
|
VQ621T/1SENSOR HYDROCARBONS VOLTAGE OUT |
1,238 | - |
|
Datasheet | VQ600 | Bulk | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 300mA |
|
IR21EJSENSOR CARBON DIOXIDE VOLT OUT |
1,820 | - |
|
Datasheet | IR2 | Bulk | Active | Carbon Dioxide (CO2) | - | ±0.5% | Voltage | -20°C ~ 60°C | 3V ~ 5V | 60mA |
|
IR11GMSENSOR CARBON DIOXIDE VOLT OUT |
1,499 | - |
|
Datasheet | IR1 | Bulk | Active | Carbon Dioxide (CO2) | - | - | Voltage | -20°C ~ 55°C | 3V ~ 5V | 60mA |
|
|
VQ641TS/1SENSOR HYDROCARBONS VOLTAGE OUT |
3,942 | - |
|
Datasheet | VQ600 | Bulk | Active | Hydrocarbons | - | - | Voltage | -20°C ~ 60°C | 2V | 100mA |
|
T8041-5VSENSOR CARBON DIOXIDE |
2,115 | - |
|
Datasheet | Ventostat® | Bulk | Active | Carbon Dioxide (CO2) | - | - | 0V ~ 5V, 0V ~ 10V | 0°C ~ 50°C | 18VAC ~ 30VAC, 18VDC ~ 42VDC | - |
|
INIR-PR2.1%SENSOR AIR QUALITY VOLTAGE OUT |
2,782 | - |
|
Datasheet | - | Bulk | Active | Air Quality | - | - | Voltage | -40°C ~ 75°C | 3.2V ~ 5.25V | 35mA |
|
PS1-CO-10-MODSENSOR CARBON MONOXIDE UART OUT |
1,163 | - |
|
Datasheet | PS1 | Bulk | Active | Carbon Monoxide (CO) | - | ±5% | UART | -40°C ~ 55°C | 3.3V ~ 5.5V | 5mA |
|
IR12GMSENSOR METHANE VOLTAGE OUTPUT |
3,738 | - |
|
Datasheet | IR1 | Bulk | Active | Methane | - | - | Voltage | -20°C ~ 55°C | 3V ~ 5V | 60mA |
|
T5100-LEDSENSOR CARBON DIOXIDE |
4,272 | - |
|
Datasheet | T5100 | Bulk | Active | Carbon Dioxide (CO2) | - | ±2% | 0V ~ 5V, 0V ~ 10V, 4mA ~ 20mA | 0°C ~ 50°C | 18VAC ~ 30VAC, 18VDC ~ 42VDC | - |
|
IR12BDSENSOR METHANE VOLTAGE OUTPUT |
4,125 | - |
|
Datasheet | IR1 | Bulk | Active | Methane | - | - | Voltage | -20°C ~ 55°C | 3V ~ 5V | 60mA |
|
IR22BDSENSOR METHANE VOLTAGE OUTPUT |
4,339 | - |
|
Datasheet | IR2 | Bulk | Active | Methane | - | - | Voltage | -20°C ~ 60°C | 3V ~ 5V | 60mA |
|
IR13BDSENSOR METHANE VOLTAGE OUTPUT |
4,742 | - |
|
Datasheet | IR1 | Bulk | Active | Methane | - | - | Voltage | -20°C ~ 55°C | 3V ~ 5V | 60mA |
Gas Sensors FAQ
Common questions about selecting, comparing and sourcing Gas Sensors components through Winsun (HK) Electronics.
What should I check when selecting Gas Sensors components?
Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.
Can Winsun help source specific Gas Sensors part numbers?
Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.
Do you support shortage, obsolete or hard-to-find Gas Sensors parts?
Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.
How do I request a quote for Gas Sensors components?
Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.