Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
EXPLORE COMPONENTS

Gas Sensors

Browse available Gas Sensors part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.

For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.

Compare Part Numbers Review available models and manufacturers
Datasheets & Specifications Access technical references quickly
RFQ & BOM Support Send quantities for sourcing and quotation
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Oxygen Range Accuracy Output Operating Temperature Voltage - Supply Current - Supply
T6613-F Amphenol Advanced Sensors (Telaire)

T6613-F

SENSOR CARBON DIOXIDE 0-4V OUT

Amphenol Advanced Sensors (Telaire)

3,926 -
Datasheet Telaire® Bulk Active Carbon Dioxide (CO2) - ±5% 0 V ~ 4 V 0°C ~ 50°C 5VDC -
T6615-10KF Amphenol Advanced Sensors (Telaire)

T6615-10KF

SENSOR CARBON DIOXIDE 0-4V OUT

Amphenol Advanced Sensors (Telaire)

4,888 -
Datasheet - Bulk Active Carbon Dioxide (CO2) - 10% 0 V ~ 4 V 0°C ~ 50°C 5VDC -
VQ22TB Amphenol SGX Sensortech

VQ22TB

SENSOR HYDROCARBONS VOLTAGE OUT

Amphenol SGX Sensortech

4,193 -
Datasheet VQ20 Bulk Active Hydrocarbons - - Voltage - 2V 175mA
T6613 Amphenol Advanced Sensors (Telaire)

T6613

SENSOR CARBON DIOXIDE 0-4V OUT

Amphenol Advanced Sensors (Telaire)

4,309 -
Datasheet Telaire® Bulk Active Carbon Dioxide (CO2) - ±5% 0 V ~ 4 V 0°C ~ 50°C 5VDC -
T6613-5K Amphenol Advanced Sensors (Telaire)

T6613-5K

SENSOR CARBON DIOXIDE 0-4V OUT

Amphenol Advanced Sensors (Telaire)

1,324 -
Datasheet - Bulk Active Carbon Dioxide (CO2) - ±5% 0 V ~ 4 V 0°C ~ 50°C 5VDC -
PS4-H2S-500 Amphenol SGX Sensortech

PS4-H2S-500

SENSOR HYDROGEN SULFIDE 500PPM

Amphenol SGX Sensortech

3,413 -
Datasheet PS4 Bulk Active Hydrogen Sulfide (H2S) 800 mbar ~ 1.2 bar - - -40°C ~ 55°C - -
101990844 Seeed Technology Co., Ltd

101990844

SENSOR CARBON DIOXIDE I2C OUTPUT

Seeed Technology Co., Ltd

4,620 -
Datasheet - Bulk Active Carbon Dioxide (CO2) - - I2C, UART - 3.05V ~ 5.5V 45µA
T6615-F Amphenol Advanced Sensors (Telaire)

T6615-F

SENSOR CARBON DIOXIDE 0-4V OUT

Amphenol Advanced Sensors (Telaire)

3,900 -
Datasheet Telaire® Bulk Active Carbon Dioxide (CO2) - 10% 0 V ~ 4 V 0°C ~ 50°C 5VDC -
T3022-1-5K-5 Amphenol Advanced Sensors (Telaire)

T3022-1-5K-5

SENSOR CARBON DIOXIDE I2C OUTPUT

Amphenol Advanced Sensors (Telaire)

2,688 -
Datasheet T3022 Bulk Active Carbon Dioxide (CO2) - ±10% I2C 0°C ~ 50°C 5V -
T6615-50KF Amphenol Advanced Sensors (Telaire)

T6615-50KF

SENSOR CARBON DIOXIDE 0-4V OUT

Amphenol Advanced Sensors (Telaire)

4,836 -
Datasheet - Bulk Active Carbon Dioxide (CO2) - 10% 0 V ~ 4 V 0°C ~ 50°C 5VDC -
PS4-SO2-50 Amphenol SGX Sensortech

PS4-SO2-50

SENSOR SULFUR DIOXIDE 50PPM

Amphenol SGX Sensortech

1,485 -
Datasheet PS4 Bulk Active Sulfur Dioxide (SO2) - - - - - -
EC4-20-SO2 Amphenol SGX Sensortech

EC4-20-SO2

SENSOR SULFUR DIOXIDE

Amphenol SGX Sensortech

3,920 -
Datasheet 4 Bulk Active Sulfur Dioxide (SO2) - - - -20°C ~ 40°C - -
COZIR-AH-E-1 Gas Sensing Solutions Ltd

COZIR-AH-E-1

SENSOR CARBON DIOXIDE UART OUT

Gas Sensing Solutions Ltd

4,076 -
Datasheet CozIR®-A Box Active Carbon Dioxide (CO2) - ±3% UART -25°C ~ 55°C 3.25V ~ 5.5V 40mA
EC4-2000-SO2 Amphenol SGX Sensortech

EC4-2000-SO2

SENSOR SULFUR DIOXIDE

Amphenol SGX Sensortech

2,144 -
Datasheet 4 Bulk Active Sulfur Dioxide (SO2) - - - -20°C ~ 50°C - -
T5100-V Amphenol Advanced Sensors (Telaire)

T5100-V

SENSOR CARBON DIOXIDE

Amphenol Advanced Sensors (Telaire)

2,455 -
Datasheet T5100 Bulk Active Carbon Dioxide (CO2) - ±2% 0V ~ 5V, 0V ~ 10V 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
PS1-HCHO-1-MOD Amphenol SGX Sensortech

PS1-HCHO-1-MOD

SENSOR FORMALDEHYDE 1PPM

Amphenol SGX Sensortech

3,306 -
Datasheet PS1 Bulk Active Formaldehyde (HCHO) 800 mbar ~ 1.2 bar - - - - -
IR12EJ Amphenol SGX Sensortech

IR12EJ

SENSOR HYDROCARBON VOLTAGE OUT

Amphenol SGX Sensortech

3,956 -
Datasheet IR1 Bulk Active Hydrocarbons, Methane - - Voltage -20°C ~ 55°C 3V ~ 5V 35mA
T0007806-NA TEKTELIC Communications Inc.

T0007806-NA

SENSOR CARBON DIOXIDE I2C OUTPUT

TEKTELIC Communications Inc.

1,056 -
Datasheet BREEZE Box Active Carbon Dioxide (CO2) - ±10% I2C 0°C ~ 60°C - -
T8042 Amphenol Advanced Sensors (Telaire)

T8042

SENSOR CARBON DIOXIDE 0-10V OUT

Amphenol Advanced Sensors (Telaire)

4,448 -
Datasheet Ventostat® Bulk Active Carbon Dioxide (CO2) - - 0 V ~ 10 V 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
T8042-5V Amphenol Advanced Sensors (Telaire)

T8042-5V

SENSOR CARBON DIOXIDE 0-5V OUT

Amphenol Advanced Sensors (Telaire)

1,926 -
Datasheet Ventostat® Bulk Active Carbon Dioxide (CO2) - - 0 V ~ 5 V 0°C ~ 50°C 18VAC ~ 30VAC, 18VDC ~ 42VDC -
Total 1306 Record«Prev1... 678910111213...66Next»
WINSUN SOURCING SUPPORT

Need Gas Sensors Sourcing Support?

Send the manufacturer, part number, quantity and target delivery requirement. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and hard-to-find or obsolete components.

Global component sourcing support BOM, shortage and EOL support
FREQUENTLY ASKED QUESTIONS

Gas Sensors FAQ

Common questions about selecting, comparing and sourcing Gas Sensors components through Winsun (HK) Electronics.

What should I check when selecting Gas Sensors components?

Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.

Can Winsun help source specific Gas Sensors part numbers?

Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.

Do you support shortage, obsolete or hard-to-find Gas Sensors parts?

Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.

How do I request a quote for Gas Sensors components?

Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.