Welcome to Winsun (HK) Electronics Limited!
+86-(0755)8253 3846
EXPLORE COMPONENTS

Gas Sensors

Browse available Gas Sensors part numbers with manufacturer references, stock information, pricing, datasheets and key specifications. Use the table below to compare options for your project.

For BOM, shortage or hard-to-find requirements, send your part number and quantity to Winsun (HK) Electronics for availability, lead-time and quotation support.

Compare Part Numbers Review available models and manufacturers
Datasheets & Specifications Access technical references quickly
RFQ & BOM Support Send quantities for sourcing and quotation
Photo Mfr. Part # Availability Price Quantity Datasheet Series Packaging Product Status Type Oxygen Range Accuracy Output Operating Temperature Voltage - Supply Current - Supply
033-9-0023 Senseair

033-9-0023

SENSEAIR K33 ICB-F 10%

Senseair

2,186 -
Datasheet K33 Box Active Carbon Dioxide (CO2) - ±3% I2C, UART 0°C ~ 50°C 5V ~ 14V 40mA
INIR-EK4 Amphenol SGX Sensortech

INIR-EK4

SENSOR AIR QUALITY VOLTAGE OUT

Amphenol SGX Sensortech

2,251 -
Datasheet - Bulk Active Air Quality - - Voltage -40°C ~ 75°C 3.2V ~ 5V 35mA
SGX-4NH3 Amphenol SGX Sensortech

SGX-4NH3

SENSOR AMMONIA

Amphenol SGX Sensortech

3,473 -
Datasheet 4 Bulk Active Ammonia (NH3) - - - -40°C ~ 50°C - -
COZIR-AH-1 Gas Sensing Solutions Ltd

COZIR-AH-1

SENSOR CARBON DIOXIDE UART OUT

Gas Sensing Solutions Ltd

4,258 -
Datasheet CozIR®-A Box Active Carbon Dioxide (CO2) 500 mbar ~ 10 bar ±3% UART, Voltage 0°C ~ 50°C 3.2V ~ 5.5V 1.5mA
PS4-O2-25% Amphenol SGX Sensortech

PS4-O2-25%

SENSOR OXYGEN

Amphenol SGX Sensortech

1,204 -
Datasheet PS4 Bulk Active Oxygen (O2) - - - -20°C ~ 55°C - -
970-500 SPEC Sensors (a division of Interlink Electronics)

970-500

SENSOR NITROGEN DIOXIDE USB OUT

SPEC Sensors (a division of Interlink Electronics)

3,847 -
Datasheet DGS2 970 Bulk Active Nitrogen Dioxide (NO2) - ±15% USB -20°C ~ 40°C 2.6V ~ 3.6V 10mA
970-400 SPEC Sensors (a division of Interlink Electronics)

970-400

SENSOR OZONE USB OUTPUT

SPEC Sensors (a division of Interlink Electronics)

2,604 -
Datasheet DGS2 970 Bulk Active Ozone (O3) - ±15% USB -20°C ~ 40°C 2.6V ~ 3.6V 10mA
T5100-I Amphenol Advanced Sensors (Telaire)

T5100-I

SENSOR CARBON DIOXIDE 4-20MA OUT

Amphenol Advanced Sensors (Telaire)

1,179 -
Datasheet T5100 Bulk Active Carbon Dioxide (CO2) - ±3% 4 ~ 20mA 0°C ~ 50°C 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC -
PS1-CO-1000-MOD Amphenol SGX Sensortech

PS1-CO-1000-MOD

SENSOR CARBON MONOXIDE

Amphenol SGX Sensortech

1,260 -
Datasheet PS1 Bulk Active Carbon Monoxide (CO) 800 mbar ~ 1.2 bar - - -40°C ~ 55°C - -
T8041 Amphenol Advanced Sensors (Telaire)

T8041

SENSOR CARBON DIOXIDE 0-10V OUT

Amphenol Advanced Sensors (Telaire)

4,565 -
Datasheet - Bulk Active Carbon Dioxide (CO2) - 3% 0 V ~ 5 V, 0 V ~ 10 V (Selectable) 0°C ~ 50°C 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC -
PS1-VOC-10-MOD Amphenol SGX Sensortech

PS1-VOC-10-MOD

SENSOR VOC UART OUTPUT

Amphenol SGX Sensortech

4,579 -
Datasheet PS1 Bulk Active Volatile Organic Compound (VOC) - ±5% UART -40°C ~ 55°C 3.3V ~ 5.5V 5mA
PS1-H2-4%-MOD Amphenol SGX Sensortech

PS1-H2-4%-MOD

SENSOR HYDROGEN

Amphenol SGX Sensortech

3,797 -
Datasheet PS1 Bulk Active Hydrogen (H2) - - - - - -
PS1-NO2-5-MOD Amphenol SGX Sensortech

PS1-NO2-5-MOD

SENSOR NITROGEN DIOXIDE 5PPM

Amphenol SGX Sensortech

1,687 -
Datasheet PS1 Bulk Active Nitrogen Dioxide (NO2) - - - - - -
OXY-LC-485 SST Sensing Ltd.

OXY-LC-485

SENSOR OXYGEN RS485 OUTPUT

SST Sensing Ltd.

1,947 -
Datasheet - Bulk Active Oxygen (O2) 260 mbar ~ 1.26 bar ±0.5% RS485 -30°C ~ 70°C 8V ~ 28V 600mA
SGX-HF-10 Amphenol SGX Sensortech

SGX-HF-10

SENSOR HYDROGEN FLUORIDE

Amphenol SGX Sensortech

3,655 -
Datasheet SGX Bulk Active Hydrogen Fluoride (HF) 800 mbar ~ 1.2 bar - - -20°C ~ 55°C - -
T3032-2-20K-24-P Amphenol Advanced Sensors (Telaire)

T3032-2-20K-24-P

SENSOR CARB DIOXIDE 4MA-20MA OUT

Amphenol Advanced Sensors (Telaire)

2,446 -
Datasheet T3000 Bulk Active Carbon Dioxide (CO2) - ±5% 4mA ~ 20mA 0°C ~ 50°C 18 VAC ~ 30VAC RMS, 18 VDC ~ 42 VDC -
ZMOD4510AI4V Renesas Electronics Corporation

ZMOD4510AI4V

SENSOR AIR QUALITY I2C OUTPUT

Renesas Electronics Corporation

2,392 -
Datasheet - Tray Active Air Quality - ±15% I2C -40°C ~ 65°C 1.7V ~ 3.6V 11mA
SEN0375 DFRobot

SEN0375

SENSOR AIR QUALITY I2C OUTPUT

DFRobot

4,292 -
Datasheet - Bulk Active Air Quality 300 mbar ~ 1.1 bar - I2C, SPI -40°C ~ 85°C 3.3V ~ 5.5V 5mA
110-508 SPEC Sensors (a division of Interlink Electronics)

110-508

SENSOR NITROGEN DIOXIDE

SPEC Sensors (a division of Interlink Electronics)

4,955 -
Datasheet - Bulk Active Nitrogen Dioxide (NO2) - - - -40°C ~ 50°C - -
110-602 SPEC Sensors (a division of Interlink Electronics)

110-602

SENSOR SULFUR DIOXIDE CUR OUT

SPEC Sensors (a division of Interlink Electronics)

4,415 -
Datasheet - Bulk Active Sulfur Dioxide - ±3% Current -30°C ~ 50°C - -
Total 1306 Record«Prev1... 4567891011...66Next»
WINSUN SOURCING SUPPORT

Need Gas Sensors Sourcing Support?

Send the manufacturer, part number, quantity and target delivery requirement. Winsun (HK) Electronics can assist with availability checks, quotation support, shortage sourcing and hard-to-find or obsolete components.

Global component sourcing support BOM, shortage and EOL support
FREQUENTLY ASKED QUESTIONS

Gas Sensors FAQ

Common questions about selecting, comparing and sourcing Gas Sensors components through Winsun (HK) Electronics.

What should I check when selecting Gas Sensors components?

Compare the manufacturer part number, electrical specifications, package, operating conditions and application requirements. The product datasheet should be used to confirm technical suitability.

Can Winsun help source specific Gas Sensors part numbers?

Yes. Send the exact part number, manufacturer and required quantity. Winsun (HK) Electronics can assist with availability checks, quotation support and sourcing options based on your requirement.

Do you support shortage, obsolete or hard-to-find Gas Sensors parts?

Yes. Our sourcing team can review shortage and obsolete-part requirements and help check available supply channels or possible alternatives when appropriate.

How do I request a quote for Gas Sensors components?

Submit an RFQ with the part number, manufacturer, quantity and target delivery requirement. Our sales team will review your request and follow up with current sourcing information.